Eaton DIN24240DC 240VA DIN Rail UPS - 24V DC Input/Output - 10-Minute Full-Load Runtime - Hardwired - LED Display
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This Eaton DIN rail UPS operates as a standby power system with a 24V DC input that matches its 24V DC output, maintaining consistent voltage for connected devices. The 240VA/240W capacity supports equipment with a power factor of 1, delivering efficient power conversion without phase adjustment requirements.
The UPS incorporates valve-regulated lead-acid battery technology with a 24V DC system voltage, providing reliable energy storage in a maintenance-free design. Environmental specifications include operation up to 122°F (50°C) and storage between 5°F (-15°C) and 104°F (40°C), with a maximum operating elevation of 9,843 feet for deployment in varied conditions.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
The DIN24240DC combines compact industrial design with essential power protection features for DC-based systems. Its DIN rail form factor enables straightforward integration into control panels and equipment racks without consuming valuable workspace.
Industrial-Grade Construction
Designed for manufacturing facilities and automation environments with hardwired connections that resist vibration and ensure reliable power delivery to critical machine controls and monitoring systems.
Clear Status Monitoring
LED indicators provide immediate visual feedback on power status with distinct modes for line power, battery operation, and fault conditions, allowing quick assessment of system health.
- POWER (Green) - Line mode active
- BATTERY (Flashing) - Running on backup
- FAULT (Red flashing) - System error detected
Deployment / Use Cases
This Eaton DIN rail UPS is specifically engineered for industrial and edge computing applications where DC power systems predominate. Its compact footprint and rail-mount design make it suitable for space-constrained installations while providing essential power continuity.
Primary deployment scenarios include factory automation control panels, network equipment in industrial settings, edge computing nodes in remote locations, and storage devices requiring brief backup during power transitions. The unit's 24V DC compatibility aligns with standard industrial control voltages, eliminating the need for additional conversion equipment.
Industrial Control Systems
Protect PLCs, sensors, and control modules in manufacturing environments where power interruptions could disrupt production processes or damage equipment.
Network Infrastructure
Provide backup power for switches, routers, and access points in industrial networks, maintaining connectivity during brief power disturbances that could otherwise cause network downtime.
Physical Profile
Measuring just 4.80 inches high, 1.50 inches wide, and 5 inches deep, this Eaton UPS offers an exceptionally compact footprint for DIN rail mounting. The 14.4-ounce weight ensures minimal load on mounting rails while the slim profile allows installation alongside other control components in standard industrial enclosures. The DIN rail clip design facilitates quick installation and removal without tools, supporting flexible deployment in evolving control panel configurations.
- Width
- 1.50" (38.10 mm)
- Depth
- 5" (127 mm)
- Height
- 4.80" (121.92 mm)
- Weight
- 40 dB(A)
What's in the Box
The package includes all components necessary for immediate deployment of the UPS system in industrial environments.
Highlights
- 240VA/240W power capacity for industrial DC equipment
- 10-minute runtime at full load, 20 minutes at half load
- 24V DC input and output for direct integration with control systems
- DIN rail mount design for panel installation in industrial enclosures
- Hardwired connections for secure electrical integration
- LED status indicators with distinct power, battery, and fault modes
- EPO (Emergency Power Off) port for safety system integration
- Valve-regulated lead-acid battery technology
- Compact dimensions: 4.80" H × 1.50" W × 5" D
- 2-year limited warranty with RoHS, REACH, and WEEE compliance
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | DIN24240DC |
| Brand Name | Eaton |
| Product Model | DIN24240DC |
| Product Name | DIN24240DC 240VA DIN Rail UPS |
| Product Type | Standby UPS |
| Technical Information | |
| Plug/Connector Type | Hardwired |
| Receptacle Type | Hardwired |
| Receptacle Detail | 1 x Hardwired |
| Phase | Single Phase |
| Application/Usage | Edge Computing,Network,Storage Device,Factory,Automation Industry,Manufacturing Facility,IT System,Industrial,Machine Control |
| Power Description | |
| Load Capacity (VA) | 240 VA |
| Load Capacity (Watt) | 240 W |
| Input Voltage | 24 V DC |
| Output Voltage | 24 V DC |
| Output Power Factor | 1 |
| Display & Graphics | |
| Display | LED |
| Controls/Indicators | |
| Status Indicators | LED Indicators: POWER (GREEN) LINE MODE ON (SOLID) BATTERY MODE (FLASHING) FAULT (RED) - FLASHING |
| Interfaces/Ports | |
| EPO Port | Yes |
| Battery Information | |
| DC System Voltage | 24 V DC |
| Battery Characteristics | Valve-regulated |
| Battery Chemistry | Lead Acid |
| Backup/Run Time (Full Load) | 10 Minute |
| Backup/Run Time (Half Load) | 20 Minute |
| Environmental Conditions | |
| Maximum Operating Elevation | 9843 ft (3000146.40 mm) |
| Storage Temperature | 5°F (-15°C) - 104°F (40°C) |
| Maximum Operating Temperature | 122°F (50°C) |
| Sound Emission (A-Weighted) | 40 dB(A) |
| Physical Characteristics | |
| Height | 4.80" (121.92 mm) |
| Width | 1.50" (38.10 mm) |
| Depth | 5" (127 mm) |
| Form Factor | DIN Rail |
| Weight (Approximate) | 14.40 oz (408.23 g) |
| Miscellaneous | |
| Package Contents | DIN24240DC 240VA DIN Rail UPS Safety Card Owner's Manual |
| Country of Origin | China |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS),Registration, Evaluation, Authorization and Restriction of Chemicals (REACH),Restriction of Hazardous Substances (RoHS) 3,Waste Electrical and Electronic Equipment Directive (WEEE) |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What is the power capacity of the Eaton DIN24240DC UPS?
The Eaton DIN24240DC provides 240 volt-amps (VA) and 240 watts (W) of power capacity. This capacity supports equipment with a power factor of 1, making it suitable for various industrial DC loads including control systems, sensors, and network equipment that require consistent 24V DC power during outages.
How long does this UPS provide backup power at full load?
At full 240W load, the DIN24240DC delivers 10 minutes of runtime from its internal battery. At half load (120W), runtime extends to 20 minutes. These durations provide sufficient time for graceful shutdowns of connected equipment or bridging brief power interruptions in industrial environments.
What type of electrical connections does this UPS use?
This Eaton UPS features hardwired connections rather than plug-and-socket receptacles. The hardwired design ensures secure, vibration-resistant electrical integration in industrial settings where reliability is critical. Installation requires proper electrical wiring to the unit's input and output terminals.
How is this UPS mounted and installed?
The DIN24240DC is designed for DIN rail mounting, the standard mounting system used in industrial control panels and equipment enclosures. Its compact dimensions (4.80" H × 1.50" W × 5" D) and 14.4-ounce weight allow installation alongside other control components without consuming significant panel space.
What voltage does this UPS accept and deliver?
This UPS operates with 24V DC input and provides 24V DC output, maintaining consistent voltage for connected DC equipment. This configuration eliminates the need for voltage conversion in industrial systems that already operate on 24V DC, simplifying integration and improving efficiency.
What environmental conditions can this UPS operate in?
The Eaton DIN24240DC operates in temperatures up to 122°F (50°C) and can be stored in temperatures from 5°F (-15°C) to 104°F (40°C). It functions at elevations up to 9,843 feet and produces only 40 dB(A) of sound emission, making it suitable for various industrial environments without excessive noise.
What power capacity is listed for this UPS?
The listed power specification is 240 VA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 24 V DC, which helps position the unit for the right load level and installation role.