Eaton EMA374-10 ePDU G3 Managed PDU - 48 Outlets IEC 60320 C13 - 230V AC Input - 24A - 72" Rack Mount
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This managed PDU operates with 230V AC input voltage, supporting a range of 200-240V AC and 346-415V AC for compatibility with various power infrastructures. The output maintains 200-240V AC across all 48 outlets, with 60Hz frequency support for consistent power delivery.
The unit incorporates branch circuit protection and single pole circuit protection to safeguard connected equipment. Remote management capabilities allow individual outlet control, enabling administrators to power cycle specific devices without physical access to the rack.
This section brings together practical product details such as PDU Type, Plug/Connector Type, Receptacle Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The Eaton ePDU G3 combines high-density power distribution with intelligent management features that optimize data center operations. With 48 C13 outlets in a single unit, this PDU maximizes rack space utilization while providing granular control over power allocation.
Intelligent Power Management
Remote outlet switching enables individual receptacle control for targeted power cycling, reducing downtime and improving maintenance efficiency.
- Monitor outlet status remotely
- Control power to specific devices
- Reduce physical access requirements
High-Density Design
Forty-eight C13 outlets in a 72-inch form factor provide exceptional outlet density for server racks and network cabinets.
- Maximizes rack space efficiency
- Reduces need for multiple PDUs
- Simplifies cable management
Comprehensive Protection
Branch circuit and single pole protection mechanisms safeguard connected equipment from electrical faults and power anomalies.
- Protects sensitive electronics
- Reduces risk of equipment damage
- Maintains system reliability
Deployment / Use Cases
This managed PDU is engineered for data centers, server rooms, and network closets where reliable, controllable power distribution is essential. The 72-inch length makes it ideal for full-height server racks, while the 48-outlet configuration supports high-density server deployments.
Remote management capabilities make this PDU particularly valuable for colocation facilities, managed service providers, and organizations with distributed IT infrastructure. The ability to power cycle individual devices remotely reduces the need for on-site technical visits, lowering operational costs and improving response times during incidents.
Data Center Server Racks
Provide power to multiple servers, switches, and storage devices in high-density rack environments with individual outlet control.
Network Operations Centers
Manage power distribution to monitoring equipment, security devices, and communication infrastructure with remote access capabilities.
Physical Profile
The Eaton ePDU G3 features a sleek black enclosure measuring 72 inches in length, 4.10 inches in width, and 2.10 inches in depth, designed specifically for standard 19-inch server racks. The 10-foot power cord provides installation flexibility, allowing connection to distant power sources while maintaining proper cable management.
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 4.10" (104.14 mm), 2.10" (53.34 mm). This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 4.10" (104.14 mm)
- Depth
- 2.10" (53.34 mm)
- Length
- 10 ft (3.05 m)
Highlights
- 48 IEC 60320 C13 outlets for high-density power distribution
- Managed PDU with remote outlet switching capabilities
- 230V AC input with 24A current capacity
- Input voltage range: 200-240V AC and 346-415V AC
- Branch circuit and single pole protection
- 72-inch rack-mountable design for full-height server racks
- IEC 60309 (532P6W) input connector
- 10-foot power cord for flexible installation
- Black finish for professional data center appearance
- 60Hz frequency support for consistent power delivery
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | EMA374-10 |
| Brand Name | Eaton |
| Product Line | ePDU |
| Product Series | G3 |
| Product Name | ePDU G3 48-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Managed |
| Plug/Connector Type | IEC 60309 (532P6W) |
| Receptacle Type | IEC 60320 C13 |
| Receptacle Detail | 48 x IEC 60320 C13 |
| Protection Type | Branch Circuit,Circuit Protection,Single Pole |
| Power Description | |
| Input Voltage | 230 V AC |
| Input Voltage Range | 200 V AC - 240 V AC,346 V AC - 415 V AC |
| Output Voltage Range | 200 V AC - 240 V AC |
| Input Current | 24 A |
| Input Frequency | 60 Hz |
| Management | |
| Remote Outlet Switching | Yes |
| Physical Characteristics | |
| Color Family | Black |
| Product Color | Black |
| Cord Length | 10 ft (3.05 m) |
| Width | 4.10" (104.14 mm) |
| Depth | 2.10" (53.34 mm) |
| Length | 72" (1828.80 mm) |
User Manual
FAQ
What type of outlets does this Eaton PDU provide?
The Eaton EMA374-10 ePDU G3 provides 48 IEC 60320 C13 outlets. These are standard computer power connectors commonly used for servers, network equipment, and other data center devices. The C13 connectors support the 230V AC input voltage with proper grounding for safe operation.
What does 'managed PDU' mean for this unit?
Managed PDU indicates this power distribution unit includes remote management capabilities, specifically remote outlet switching. This allows administrators to monitor and control individual receptacles through network connectivity, enabling remote power cycling of connected devices without physical access to the rack.
What input voltage does this PDU support?
This PDU supports 230V AC input voltage with a range of 200-240V AC and 346-415V AC. The dual range provides compatibility with various power infrastructures, making it suitable for international deployments and different electrical system configurations.
What is the maximum current rating for this Eaton PDU?
The Eaton EMA374-10 has a 24A input current rating. This determines the maximum electrical current the PDU can handle from the power source, which influences how many devices can be safely connected and operated simultaneously based on their individual power requirements.
What protection features does this PDU include?
This PDU includes branch circuit protection, circuit protection, and single pole protection. These features safeguard connected equipment from electrical faults, overload conditions, and power anomalies, helping to prevent damage to sensitive servers and network devices in data center environments.
What are the physical dimensions of this PDU?
The PDU measures 72 inches in length, 4.10 inches in width, and 2.10 inches in depth. The 72-inch length makes it suitable for full-height server racks, while the slim profile minimizes space usage. The unit includes a 10-foot power cord for flexible installation positioning within the rack environment.
What power capacity is listed for this UPS?
Power specifications help show where the unit fits best, including the type of load level, electrical environment, and backup role it is intended to support. These are usually the most decision-critical facts in a UPS or power-protection comparison.
How many outlets are available?
The product includes Yes, which helps buyers understand how many connected devices it can support in its intended deployment.