Eaton EMA325-10 ePDU G3 Managed 38U Vertical Rack PDU - 5. 76 kW - 24 Outlets - 6xC19 - 18xC13 - NEMA L21-20P 16A Input - 120/230V AC

SKU: EMA325-10
UPC: 786685932040
(No reviews) Write a Review
MSRP: $2,551.99
$2,551.99
$2,275.99
Save: $276.00 (10.82%)
Warranty Information: Covered by Manufacturer
Condition: New
Width: 5.21 (cm)
Height: 1.23 (cm)
Depth: 6.50 (cm)

Ask for ETA! 🗨️

Logo cards
B2B Pricing

Business volume discounts

IT Experts

Technical guidance

IT Configuration

Preparation & staging

Canada Stock

QC · ON · AB · BC

Product Features

Description

Product Overview

The Eaton EMA325-10 ePDU G3 Managed is a high-density vertical rack power distribution unit engineered for modern data center and server room environments. This 38U PDU delivers 5.76 kW of power capacity across 24 outlets, providing reliable and scalable power distribution for critical IT equipment.

Featuring a NEMA L21-20P input connector rated at 16A, it supports dual voltage input (120/230V AC) with a range of 120-208V AC, offering flexibility in various power infrastructures. The managed capabilities via RJ-45 network connectivity enable remote monitoring, control, and power sequencing, enhancing operational efficiency and uptime.

This section brings together practical product details such as Plug/Connector Type, Plug/Connector Detail, Receptacle Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.

Power
5.76 kW
Power Capacity
120 V AC,230 V AC38U
Power Capacity & Input
Power Rating5.76 kW
Input Current16 A
Input Voltage120 V AC, 230 V AC
Output Configuration
Total Outlets24
C19 Outlets6 x IEC 60320 C19
C13 Outlets18 x IEC 60320 C13
Physical & Installation
Rack Height38U
MountingVertical
Network ManagementYes (RJ-45)

Technical Overview

This Eaton ePDU G3 is built with a robust power architecture, delivering 230V AC output voltage to support high-power server and networking gear. The input accommodates a wide voltage range, ensuring compatibility with standard North American and international power systems.

The outlet configuration includes 6 IEC C19 and 18 IEC C13 receptacles, catering to a mix of high-power and standard equipment connections. This distribution optimizes rack space and reduces cable clutter, while the vertical 38U form factor maximizes power delivery along the full height of the rack.

This section brings together practical product details such as Plug/Connector Type, Plug/Connector Detail, Receptacle Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.

A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.

Power Capacity5.76 kW
Input Voltage Range120-208V AC
Output Voltage230V AC
Managed PDUVertical Mount24 Outlets

Key Product Advantages

The EMA325-10 combines high power density with intelligent management, making it a strategic choice for data centers requiring precise power control and visibility. Its design prioritizes reliability, scalability, and ease of integration into existing rack environments.

High-Density Power Distribution

With 24 outlets in a 38U vertical footprint, this PDU supports dense server and network deployments without sacrificing power availability or requiring additional units.

  • 6 C19 outlets for high-power devices
  • 18 C13 outlets for standard equipment
  • 5.76 kW total capacity

Network-Managed Control

RJ-45 connectivity enables remote power monitoring, outlet-level control, and environmental sensing integration, allowing IT teams to manage power usage and respond to issues proactively.

  • Remote reboot capabilities
  • Power usage analytics
  • Alerts and notifications

Flexible Voltage Compatibility

Dual input voltage support (120/230V AC) and a wide input range provide installation flexibility across different power infrastructures, reducing compatibility concerns during deployment.

  • 120-208V AC input range
  • 230V AC output
  • NEMA L21-20P connector

Deployment / Use Cases

This managed PDU is ideal for data centers, server rooms, and network closets where reliable power distribution and remote management are critical. Its vertical 38U design fits standard server racks, providing power along the entire rack height for efficient cable management.

Common applications include powering high-density server racks, network switches, storage arrays, and telecommunications equipment. The outlet mix supports both high-power devices (via C19) and standard IT gear (via C13), making it versatile for mixed environments.

Data Center Server Racks

Deploy in enterprise data centers to power blade servers, rack-mounted servers, and associated networking equipment, with remote management for operational efficiency.

Network and Telecom Closets

Use in network closets or telecom rooms to distribute power to switches, routers, and other critical infrastructure, with the ability to monitor power consumption and perform remote reboots.

Physical Profile

The Eaton ePDU G3 features a vertical mounting orientation with a 38U rack height, measuring 66.50 inches (1689.10 mm) in height, 2.05 inches (52.07 mm) in width, and 2.56 inches (65.02 mm) in depth. This slim profile minimizes rack space usage while providing full-length power distribution. The vertical design aids in cable management and airflow, and the unit is manufactured in the United States.

Dimensions
Width
2.05" (52.07 mm)
Depth
2.56" (65.02 mm)
Height
38U
[custom-highlights]

Highlights

  • 5.76 kW power capacity for high-density rack deployments
  • 24 total outlets: 6 IEC C19 and 18 IEC C13 receptacles
  • NEMA L21-20P input connector with 16A current rating
  • Dual input voltage: 120V AC and 230V AC support
  • Network-managed via RJ-45 for remote monitoring and control
  • Vertical 38U rack-mount design for full-height power distribution
  • Input voltage range of 120-208V AC for flexible installation
  • 230V AC output voltage optimized for server and network gear
[/custom-highlights][custom-specifications]

Specifications

Specifications
ManufacturerEaton Corporation
Manufacturer Part NumberEMA325-10
Brand NameEaton
Product LineePDU
Product NameePDU 24-Outlet PDU
Product TypePDU
Technical Information
Plug/Connector TypeNEMA L21-20P
Plug/Connector Detail1 x NEMA L21-20P
Receptacle TypeIEC 60320 C19,IEC 60320 C13
Receptacle Detail6 x IEC 60320 C19,18 x IEC 60320 C13
Power Description
Input Voltage120 V AC,230 V AC
Input Voltage Range120 V AC - 208 V AC
Output Voltage230 V AC
Power Rating (Watt)5.76 kW
Input Current16 A
Interfaces/Ports
Network (RJ-45)Yes
Physical Characteristics
Mounting OrientationVertical
Rack Height38U
Height66.50" (1689.10 mm)
Width2.05" (52.07 mm)
Depth2.56" (65.02 mm)
Miscellaneous
Country of OriginUnited States
[/custom-specifications][custom-user-manual]

User Manual

This section contains official documentation provided by the manufacturer, including product manuals, brochures, and supplementary materials.
[/custom-user-manual][custom-faq]

FAQ

What is the power capacity of this Eaton ePDU?

The Eaton EMA325-10 ePDU G3 has a power rating of 5.76 kW (5760 watts). This capacity supports high-density server and network equipment in rack environments, providing sufficient power for multiple devices without overloading the unit.

How many outlets does this PDU have and what types are they?

This PDU features 24 total outlets: 6 IEC 60320 C19 outlets for high-power devices and 18 IEC 60320 C13 outlets for standard equipment. This mix allows flexible power distribution for a variety of IT gear in a rack setup.

What input voltage does this Eaton ePDU support?

The Eaton ePDU supports dual input voltages of 120V AC and 230V AC, with an input voltage range of 120-208V AC. This flexibility accommodates different power infrastructures, making it suitable for various data center and server room configurations.

Is this PDU managed and how is it controlled?

Yes, this is a managed ePDU with network connectivity via an RJ-45 port. It allows remote monitoring, outlet-level control, power sequencing, and environmental sensing, enabling IT teams to manage power usage and respond to issues from a central interface.

What rack mounting orientation and height does this PDU use?

This Eaton ePDU is designed for vertical mounting with a rack height of 38U. It measures 66.50 inches in height, fitting standard server racks to provide power distribution along the full rack height, which aids in cable management and efficient power delivery.

What type of input connector does this PDU have?

The PDU uses a NEMA L21-20P input connector rated at 16A. This connector type is common in three-phase power systems and provides a secure connection for the unit's high power capacity in data center environments.

What power capacity is listed for this UPS?

The listed power specification is 5.76 kW, which helps position the unit for the right load level and installation role.

What voltage details are listed?

The listed power specification is 120 V AC,230 V AC, which helps position the unit for the right load level and installation role.

[/custom-faq]
Volume Discounts
Qty Price Available
Match Price Request

Found a lower price? Send us the link and we will do our best to match or beat it.

Request received. We will reply within 24 hours.
Fleet Network
Wholesale & B2B
Partner with Us

Looking to buy in bulk? We offer competitive pricing, dedicated support, and custom solutions for businesses of all sizes.

Volume Discounts

Tiered pricing structure designed to maximize your margins as you grow.

Dedicated Account Manager

Direct access to a specialist who understands your business needs.

Fast & Reliable Shipping

Priority processing and discounted shipping rates for bulk orders.

Request a Quote
Thank you!
Your request has been sent successfully.
Eaton EMA325-10 ePDU G3 Managed 38U Vertical Rack PDU - 5. 76 kW - 24 Outlets - 6xC19 - 18xC13 - NEMA L21-20P 16A Input - 120/230V AC
MSRP: $2,551.99
$2,551.99
$2,275.99
Save: $276.00 (10.82%)
Out of stock