Eaton EVMA4609X-06 G4 Managed Rack PDU - 42 Outlets - 24x C13 - 18x C39 - 17. 3 kW - 230V AC - 0U Vertical
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This managed PDU operates on three-phase 230V AC power with a 60A input current, delivering 17.3 kW of total power capacity. The outlet configuration includes 24 IEC 60320 C13 receptacles and 18 IEC 60320 C39 receptacles, providing flexibility for various server and networking equipment connections.
The unit features a 460P9W plug/connector type and includes a 6-foot (1.83 m) power cord. Network management capabilities are enabled through an RJ-45 interface, allowing for remote monitoring, outlet-level control, and environmental threshold alerts. The PDU supports operating temperatures from 32°F to 140°F (0°C to 60°C) and carries a 3-year limited warranty.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
High-Density Power Distribution
With 42 total outlets (24 C13 and 18 C39), this PDU supports dense server and networking equipment deployments while maintaining organized power distribution.
- 24 IEC C13 outlets for standard equipment
- 18 IEC C39 outlets for high-power devices
- 17.3 kW total power capacity
Space-Efficient Rack Design
The 0U vertical form factor maximizes rack space utilization by mounting vertically in standard 19-inch racks without consuming rack units.
- Zero rack unit consumption
- Vertical mounting orientation
- Compact 2.56" width profile
Intelligent Power Management
Network connectivity enables remote monitoring, outlet-level control, and power management capabilities for improved infrastructure oversight.
- RJ-45 network interface
- Remote monitoring and control
- Outlet-level power management
Deployment / Use Cases
This managed rack PDU is engineered for data centers, server rooms, and network closets where reliable, monitored power distribution is essential. The 42-outlet configuration supports high-density server deployments, networking equipment racks, and storage arrays requiring multiple power connections.
The three-phase 230V AC input and 17.3 kW capacity make it suitable for powering enterprise server racks, blade chassis, network switches, and other critical infrastructure. The managed capabilities allow IT administrators to implement power sequencing, monitor load conditions, and receive alerts for power-related events, enhancing overall infrastructure reliability and management efficiency.
Data Center Server Racks
Ideal for powering high-density server deployments with multiple C13 and C39 connections, providing monitored power distribution for critical applications.
Network Equipment Cabinets
Supports networking infrastructure with outlet-level control and monitoring capabilities for switches, routers, and other network devices.
Physical Profile
The PDU features a vertical rack-mount design with dimensions of 72" height × 2.56" width × 2.05" depth (1828.80 mm × 65.02 mm × 52.07 mm). The 0U form factor allows vertical installation in standard 19-inch racks without consuming rack unit space. Weighing approximately 28.20 lb (12791.30 g), the unit includes a 6-foot (1.83 m) power cord for flexible installation options.
- Width
- 2.56" (65.02 mm)
- Depth
- 2.05" (52.07 mm)
- Height
- 0U
- Weight
- 28.20 lb (12791.30 g)
- Length
- 6 ft (1.83 m)
Highlights
- Managed rack PDU with 42 total outlets (24 IEC C13, 18 IEC C39)
- 17.3 kW power capacity with three-phase 230V AC input
- 0U vertical form factor for space-efficient rack mounting
- Network management via RJ-45 for remote monitoring and control
- Vertical mounting orientation with 6-foot power cord
- Three-phase power distribution for high-density deployments
- Operating temperature range: 32°F to 140°F (0°C to 60°C)
- 3-year limited warranty for reliable performance
- Compact design: 72"H × 2.56"W × 2.05"D
- 460P9W plug/connector type for secure power connection
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | EVMA4609X-06 |
| Brand Name | Eaton |
| Product Series | G4 |
| Product Name | G4 42-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Managed |
| Phase | Three Phase |
| Plug/Connector Type | 460P9W |
| Receptacle Type | IEC 60320 C13,IEC 60320 C39 |
| Receptacle Detail | 24 x IEC 60320 C13,18 x IEC 60320 C39 |
| Power Description | |
| Input Voltage | 230 V AC |
| Power Rating (Watt) | 17.30 kW |
| Input Current | 60 A |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Mounting Orientation | Vertical |
| Form Factor | Rack |
| Rack Height | 0U |
| Cord Length | 6 ft (1.83 m) |
| Height | 72" (1828.80 mm) |
| Width | 2.56" (65.02 mm) |
| Depth | 2.05" (52.07 mm) |
| Length | 2.05" (52.07 mm) |
| Weight (Approximate) | 28.20 lb (12791.30 g) |
| Environmental Conditions | |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Operating Temperature | 140°F (60°C) |
| Miscellaneous | |
| Country of Origin | Philippines |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the total power capacity of this Eaton PDU?
The Eaton EVMA4609X-06 PDU has a total power capacity of 17.30 kW (17,300 watts). This three-phase unit operates at 230V AC with a 60A input current, making it suitable for powering high-density server racks and networking equipment in data center environments.
How many outlets does this rack PDU have and what types are they?
This PDU features 42 total outlets with a mixed configuration: 24 IEC 60320 C13 receptacles and 18 IEC 60320 C39 receptacles. The C13 outlets are standard for most server and networking equipment, while the C39 outlets support higher-power devices, providing flexibility for various equipment types in rack deployments.
What does 'managed PDU' mean for this Eaton unit?
A managed PDU includes network connectivity (RJ-45 in this case) that enables remote monitoring and control capabilities. This allows IT administrators to monitor power consumption at the outlet level, control individual outlets remotely, set power thresholds, receive alerts for power events, and implement power sequencing strategies from a centralized management interface.
How is this PDU mounted in a server rack?
This PDU uses a 0U vertical mounting form factor, meaning it installs vertically in standard 19-inch racks without consuming any rack units. The vertical orientation and compact 2.56" width allow it to mount alongside equipment in the rack while maximizing usable space for servers and networking gear.
What is the operating temperature range for this PDU?
The Eaton EVMA4609X-06 PDU operates within a temperature range of 32°F to 140°F (0°C to 60°C). This range makes it suitable for standard data center and server room environments where temperature-controlled conditions are maintained for optimal equipment performance and reliability.
What warranty coverage does this Eaton PDU include?
This Eaton PDU comes with a 3-year limited warranty that covers manufacturing defects and ensures reliable performance. The warranty provides peace of mind for critical infrastructure deployments where uninterrupted power distribution is essential for business operations.
What power capacity is listed for this UPS?
The listed power specification is 17.30 kW, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 230 V AC, which helps position the unit for the right load level and installation role.