Sidebar Sidebar Sidebar
sale
Sold out

Shipping included*

Eaton EVMAG332C G4 Managed 48-Outlet Rack PDU - 17. 3 kW/kVA - 24x C13 & 24x C39 - 230/415V AC - 0U Vertical

SKU: EVMAG332C
UPC: 786689795054
(No reviews) Write a Review
MSRP: $4,347.63
$4,347.63
$3,251.99
Save: $1,095.64 (25.20%)
Warranty Information: 3 Year
Condition: New
Width: 5.08 (cm)
Height: 1.23 (cm)
Depth: 5.28 (cm)

Ask for ETA! 🗨️

Logo cards
B2B Pricing

Business volume discounts

IT Experts

Technical guidance

IT Configuration

Preparation & staging

Canada Stock

QC · ON · AB · BC

Product Features

Description

Product Overview

The Eaton G4 EVMAG332C is a managed 48-outlet rack PDU designed for high-density data center and IT equipment power distribution. This three-phase unit delivers 17.3 kW/kVA of reliable power capacity with advanced monitoring and control features through its integrated SNMP Gigabit network module.

Engineered for vertical 0U rack mounting, the PDU features a balanced mix of 24 IEC C13 and 24 IEC C39 outlets to accommodate a wide range of server, networking, and storage devices. The built-in LCD display provides real-time load monitoring, while overload protection safeguards connected equipment against power anomalies.

This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.

Power
17.30 kW
Power Capacity
230 V AC,415 V ACVertical
Power Capacity & Electrical
Power Rating17.30 kVA / 17.30 kW
Input Voltage230 V AC, 415 V AC
Input Current32 A
Outlet Configuration
Total Outlets48
Receptacle Types24 x IEC 60320 C13, 24 x IEC 60320 C39
Plug Type532P6W
Physical & Installation
Form FactorVertical Rack, 0U Height
MountingRack-mountable with Button Mount
Cord Length10 ft (3.05 m)
Management & Protection
ManagementSNMP Gigabit Network Module G4
ProtectionSingle Pole, Overload Protection
DisplayLCD Display

Technical Overview

This managed PDU operates with a three-phase electrical design, accepting input voltages of 230V AC or 415V AC at 32A. It delivers output voltages configurable for 415V AC, 240V AC, or 208V AC environments, making it versatile for international data center deployments.

The unit's 17.3 kVA/17.3 kW power rating supports demanding IT loads, while its 0U vertical form factor maximizes rack space efficiency. Network management is handled through a dedicated Gigabit Ethernet port (RJ-45), enabling remote monitoring, power cycling, and environmental threshold alerts via SNMP.

This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.

A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.

Power Capacity17.3 kW/kVA
Input Current32 A
Operating Temperature32°F to 140°F (0°C to 60°C)
Three PhaseManagedVertical RackSNMP

Key Product Advantages

The Eaton G4 EVMAG332C combines high outlet density with enterprise-grade management capabilities, providing data center operators with precise control over power distribution. Its 48-outlet configuration reduces the need for multiple PDUs, simplifying cable management and improving rack organization.

High-Density Power Distribution

With 48 outlets (24 C13 + 24 C39), this PDU supports numerous devices in a single vertical unit, optimizing rack space and reducing clutter.

  • 24 IEC C13 outlets for standard equipment
  • 24 IEC C39 outlets for high-power devices
  • Balanced outlet mix for flexible deployment

Advanced Remote Management

The integrated SNMP Gigabit network module enables comprehensive remote monitoring and control, allowing administrators to manage power usage, set alerts, and perform reboots without physical access.

  • Real-time load monitoring via LCD
  • SNMP v1/v2c/v3 support
  • Environmental threshold alerts

Rack-Optimized Design

The 0U vertical form factor installs efficiently in standard 19-inch racks without consuming horizontal U space, while the 10-foot power cord provides flexible placement options.

  • Vertical mounting saves rack units
  • Button mount for secure installation
  • 10 ft cord for reach flexibility

Deployment / Use Cases

This managed PDU is engineered for data center environments where reliable, monitored power distribution is critical. Its high outlet count and three-phase power capacity make it ideal for server racks, network cabinets, and storage arrays in enterprise and colocation facilities.

The unit's SNMP management capabilities support automated infrastructure monitoring, enabling integration with existing data center management systems. IT teams can use the PDU for power usage tracking, capacity planning, and remote device reboots, reducing downtime and operational costs.

Data Center Server Racks

Power high-density server deployments with consistent, monitored three-phase power, using the mix of C13 and C39 outlets for various server and storage configurations.

Network Equipment Cabinets

Distribute power to switches, routers, and other networking gear while maintaining remote management capabilities for network operations centers.

Physical Profile

The Eaton G4 EVMAG332C features a sleek black vertical design measuring 74.80 inches in height, 2 inches in width, and 2.08 inches in depth. With a weight of approximately 19.40 pounds, it installs securely in standard 19-inch racks using the included button mount hardware. The vertical orientation and 0U footprint maximize usable rack space while providing easy access to all 48 outlets.

Color
Black
Dimensions
Width
2" (50.80 mm)
Depth
2.08" (52.83 mm)
Height
0U
Weight
19.40 lb (8799.69 g)
Length
10 ft (3.05 m)
Dimensions74.80" H × 2" W × 2.08" D
Weight19.40 lb
Rack Height0U

What's in the Box

The package includes the G4 EVMAG332C 48-outlet PDU and mounting buttons for secure rack installation.

Package contents include G4 EVMAG332C 48-Outlets PDU Mounting Buttons, G4 EVMAG332C 48-Outlets PDU. These included items support setup, installation, and immediate deployment without needing to source the core bundled accessories separately.

G4 EVMAG332C 48-Outlets PDU Mounting Buttons
G4 EVMAG332C 48-Outlets PDU
[custom-highlights]

Highlights

  • Managed 48-outlet rack PDU with 17.3 kW/kVA power capacity
  • Three-phase operation with 230V/415V AC input and 32A current
  • 24 IEC C13 outlets plus 24 IEC C39 outlets for versatile device support
  • SNMP Gigabit network module for remote monitoring and control
  • Vertical 0U form factor with button mount for space-efficient rack installation
  • LCD display for real-time load monitoring at the rack
  • 10-foot power cord provides flexible placement options
  • Single pole overload protection safeguards connected equipment
  • RoHS compliant and TAA compliant for government deployments
  • 3-year limited warranty from Eaton
[/custom-highlights][custom-specifications]

Specifications

Specifications
ManufacturerEaton Corporation
Manufacturer Part NumberEVMAG332C
Brand NameEaton
Product SeriesG4
Product ModelEVMAG332C
Product NameG4 EVMAG332C 48-Outlets PDU
Product TypePDU
Technical Information
PDU TypeManaged
PhaseThree Phase
Plug/Connector Type532P6W
Receptacle TypeIEC 60320 C13,IEC 60320 C39
Receptacle Detail24 x IEC 60320 C13,24 x IEC 60320 C39
Protection TypeSingle Pole,Overload Protection
FeaturesLCD Display
Load Capacity (VA)17.30 kW
Load Capacity (Watt)17.30 kW
Power Description
Input Voltage230 V AC,415 V AC
Output Voltage415 V AC,240 V AC,208 V AC
Power Rating (VA)17.30 kVA
Power Rating (Watt)17.30 kW
Input Current32 A
Management
ManagementSNMP Gigabit Network Module G4
Interfaces/Ports
Network (RJ-45)Yes
Physical Characteristics
Color FamilyBlack
Product ColorBlack
Mounting OrientationVertical
Mount TypeRack-mountable,Button Mount
Form FactorVertical
Rack Height0U
Cord Length10 ft (3.05 m)
Height74.80" (1899.92 mm)
Width2" (50.80 mm)
Depth2.08" (52.83 mm)
Weight (Approximate)19.40 lb (8799.69 g)
Environmental Conditions
Minimum Operating Temperature32°F (0°C)
Maximum Operating Temperature140°F (60°C)
Minimum Storage Temperature-13°F (-25°C)
Maximum Storage Temperature149°F (65°C)
Miscellaneous
Package ContentsG4 EVMAG332C 48-Outlets PDU Mounting Buttons
Application/UsageData Center,IT Equipment
Country of OriginMorocco
TAA CompliantYes
Environmental ComplianceRestriction of Hazardous Substances (RoHS)
Warranty
Limited Warranty3 Year
[/custom-specifications][custom-user-manual]

User Manual

This section contains official documentation provided by the manufacturer, including product manuals, brochures, and supplementary materials.
[/custom-user-manual][custom-faq]

FAQ

What is the power capacity of this Eaton PDU?

The Eaton G4 EVMAG332C delivers 17.30 kVA (17.30 kW) of power capacity, supporting high-density IT equipment in data center environments. This three-phase unit handles substantial electrical loads while maintaining reliable power distribution to all 48 outlets.

How many outlets does this PDU have and what types are they?

This PDU features 48 total outlets: 24 IEC 60320 C13 outlets and 24 IEC 60320 C39 outlets. The C13 outlets are standard for most IT equipment, while the C39 outlets support higher-power devices, providing flexibility for mixed equipment deployments in server racks.

What management capabilities does this PDU offer?

The PDU includes an integrated SNMP Gigabit network module for comprehensive remote management. Administrators can monitor real-time power usage via the LCD display or remotely through SNMP, set environmental thresholds, receive alerts, and perform remote reboots of connected equipment.

How is this PDU mounted in a rack?

This PDU uses a vertical 0U form factor with button mount installation. It mounts vertically in standard 19-inch racks without consuming horizontal rack units, maximizing usable space. The included mounting buttons provide secure attachment, and the 10-foot power cord offers placement flexibility.

What input voltages does this PDU support?

The Eaton G4 EVMAG332C accepts three-phase input voltages of 230V AC or 415V AC at 32A. It delivers output voltages configurable for 415V AC, 240V AC, or 208V AC, making it suitable for various international data center power standards and electrical configurations.

What protection features does this PDU include?

This managed PDU provides single pole overload protection to safeguard connected equipment against power anomalies. The protection system works in conjunction with the monitoring capabilities to prevent damage from electrical faults while maintaining continuous operation of critical IT infrastructure.

What power capacity is listed for this UPS?

The listed power specification is 17.30 kW, which helps position the unit for the right load level and installation role.

What voltage details are listed?

The listed power specification is 230 V AC,415 V AC, which helps position the unit for the right load level and installation role.

[/custom-faq]
Volume Discounts
Qty Price Available
Match Price Request

Found a lower price? Send us the link and we will do our best to match or beat it.

Request received. We will reply within 24 hours.
Fleet Network
Wholesale & B2B
Partner with Us

Looking to buy in bulk? We offer competitive pricing, dedicated support, and custom solutions for businesses of all sizes.

Volume Discounts

Tiered pricing structure designed to maximize your margins as you grow.

Dedicated Account Manager

Direct access to a specialist who understands your business needs.

Fast & Reliable Shipping

Priority processing and discounted shipping rates for bulk orders.

Request a Quote
Thank you!
Your request has been sent successfully.
Eaton EVMAG332C G4 Managed 48-Outlet Rack PDU - 17. 3 kW/kVA - 24x C13 & 24x C39 - 230/415V AC - 0U Vertical
MSRP: $4,347.63
$4,347.63
$3,251.99
Save: $1,095.64 (25.20%)
Out of stock