Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Eaton 124100028-003 Maintenance Bypass Panel Transfer Switch - 30 kW - 208V AC - Wall-Mountable
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This maintenance bypass panel operates as a manual transfer switch that routes power directly from the utility source to the critical load, bypassing the UPS during service intervals. The 30 kW capacity specification indicates its ability to support substantial connected equipment loads without performance degradation. The 208V AC output voltage aligns with common three-phase power distribution standards in commercial and industrial settings.
The panel's design incorporates heavy-duty switching mechanisms and safety interlocks to prevent accidental power interruptions or hazardous conditions during operation. While specific input voltage details aren't provided, the compatibility with Eaton Powerware 9355 UPS systems ensures proper electrical integration when deployed as part of a complete power protection solution.
Key Product Advantages
This Eaton bypass panel delivers essential functionality for maintaining uptime during UPS service operations. The manual transfer capability allows technicians to safely isolate the UPS for maintenance while keeping critical systems powered directly from the utility source. This eliminates the need for complete system shutdowns during routine service or emergency repairs.
Maintenance Without Downtime
Enables UPS maintenance, testing, or replacement while connected equipment continues operating on utility power.
- No service interruptions
- Safe technician access
- Continuous load power
Enterprise-Grade Construction
Built with industrial-grade components to handle 30 kW loads reliably in demanding environments.
- Heavy-duty switching
- Safety interlocks
- Robust enclosure
Seamless Integration
Designed specifically for Eaton Powerware 9355 20-30 kVA UPS systems for guaranteed compatibility.
- Direct UPS connection
- Proper voltage matching
- Standard mounting
Deployment / Use Cases
The Eaton 124100028-003 Maintenance Bypass Panel is essential for any installation where UPS maintenance cannot coincide with system downtime. Data centers implementing scheduled maintenance windows benefit from this panel's ability to keep servers and networking equipment operational during UPS service. Server rooms in financial institutions, healthcare facilities, and manufacturing plants similarly require this continuous power capability to maintain critical operations.
Industrial environments with process control systems utilize these bypass panels to ensure manufacturing lines remain operational during power system maintenance. The wall-mountable design makes it suitable for both new installations and retrofits in equipment rooms where floor space is limited. IT managers deploy this component as part of comprehensive disaster recovery plans, knowing they can service UPS hardware without affecting business continuity.
Physical Profile
The bypass panel features a substantial gray steel enclosure measuring 72 inches in height, 20 inches in width, and 5.80 inches in depth. This vertical form factor optimizes wall space utilization in equipment rooms while providing ample internal space for electrical components and safety features. The 450-pound weight reflects the robust construction and heavy-duty internal components designed for long-term reliability.
The wall-mountable design includes standardized mounting points for secure installation on reinforced walls or frames. The gray finish provides a professional appearance that blends with typical data center and server room environments. All controls and indicators are positioned for clear visibility and safe operation during transfer procedures.
- Width
- 20" (508 mm)
- Depth
- 5.80" (147.32 mm)
- Height
- 72" (1828.80 mm)
- Weight
- 450 lb (204116.57 g)
Highlights
- 30 kW load capacity for substantial power requirements
- 208V AC output voltage for commercial/industrial applications
- Wall-mountable gray enclosure saves floor space
- Compatible with Eaton Powerware 9355 20-30 kVA UPS systems
- Enables UPS maintenance without load interruption
- Manual transfer switch with safety interlocks
- Manufactured in the United States
- Heavy-duty construction (450 lb weight)
- Standardized dimensions for predictable installation
- Professional-grade components for reliable operation
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | 124100028-003 |
| Brand Name | Eaton |
| Product Name | Maintenance Bypass Panel Transfer Switch |
| Product Type | Bypass Panel |
| Power Description | |
| Load Capacity (VA) | 30 kW |
| Output Voltage | 208 V AC |
| Physical Characteristics | |
| Color Family | Gray |
| Product Color | Gray |
| Form Factor | Wall-mountable |
| Height | 72" (1828.80 mm) |
| Width | 20" (508 mm) |
| Depth | 5.80" (147.32 mm) |
| Weight (Approximate) | 450 lb (204116.57 g) |
| Miscellaneous | |
| Compatibility | Eaton Powerware 9355 20-30 kVA UPS |
| Country of Origin | United States |
FAQ
What is the primary function of this Eaton bypass panel?
The Eaton 124100028-003 Maintenance Bypass Panel Transfer Switch provides a manual method to route power directly from the utility source to connected equipment, bypassing the UPS. This allows technicians to safely perform maintenance, testing, or replacement on the Eaton Powerware 9355 UPS without interrupting power to critical loads. It's essential for environments where uptime must be maintained during service operations.
What UPS systems is this bypass panel compatible with?
This bypass panel is specifically designed for compatibility with Eaton Powerware 9355 20-30 kVA UPS systems. The electrical specifications and physical connections are engineered to integrate seamlessly with these UPS models. Always verify compatibility with your specific UPS configuration before installation, as using it with incompatible systems may not provide proper functionality or safety.
What are the physical dimensions and weight of this unit?
The panel measures 72 inches in height, 20 inches in width, and 5.80 inches in depth (1828.80 mm × 508 mm × 147.32 mm). It weighs approximately 450 pounds (204116.57 grams). These substantial dimensions and weight require proper wall reinforcement and professional installation to ensure secure mounting and safe operation in your facility.
What power capacity does this bypass panel support?
The Eaton 124100028-003 supports a load capacity of 30 kW with an output voltage of 208V AC. This capacity makes it suitable for substantial power requirements in data centers, server rooms, and industrial applications. The 208V AC output aligns with common three-phase power distribution standards used in commercial and industrial environments.
How is this bypass panel installed?
This is a wall-mountable unit designed for vertical installation on reinforced walls or frames. The installation requires proper electrical connections to both the utility power source and the Eaton Powerware 9355 UPS system. Due to the 450-pound weight and electrical complexity, professional installation by qualified technicians is strongly recommended to ensure safety, proper operation, and compliance with electrical codes.
What safety features does this bypass panel include?
While specific safety certifications aren't detailed in product details, the design incorporates safety interlocks to prevent accidental power interruptions or hazardous conditions during transfer operations. The manual transfer mechanism requires deliberate operator action, and the robust enclosure protects internal components. Always follow Eaton's installation and operation guidelines to maintain safe working conditions.