Eaton EMI344-10 Metered Input Rack PDU - 0U - 8. 64 kW - L21-30P Input - 24A - 120/208V - 24 NEMA 5-20R Outlets - 10 ft Cord
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This Eaton Metered Input Rack PDU operates with a 24A input current and delivers power at 120/208V, ensuring compatibility with standard three-phase power sources commonly found in commercial and data center settings. The unit's 8.64 kW power rating provides substantial capacity for high-density rack deployments, while the 24 NEMA 5-20R outlets accommodate a wide range of IT equipment with standard North American plugs.
The PDU incorporates Eaton Hydraulic Magnetic Circuit Breakers that offer accidental trip protection, enhancing reliability by preventing nuisance trips during inrush currents. Phase branch level metering enables detailed monitoring of power usage across each phase, facilitating proactive load management and helping to avoid circuit overloads that could lead to downtime.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Power Rating (Watt), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
The Eaton EMI344-10 stands out with its combination of robust power capacity, detailed monitoring capabilities, and secure design features that address common data center power management challenges.
Enhanced Security and Control
User access control with password protection and SSL configurable to 1024 or 2048 bit ensures that power management settings remain secure from unauthorized changes, while colour-coded outlet and branch circuits simplify visual load balancing during installation and maintenance.
- User access control
- Password protection
- SSL encryption
Reliable Connection Retention
IEC outlet eGrip plug retention securely holds all standard IEC plugs in place, preventing accidental disconnections that could interrupt critical equipment operation in vibration-prone environments.
- eGrip plug retention
- Prevents accidental disconnection
Deployment / Use Cases
This metered input rack PDU is specifically designed for environments where power distribution needs to be both high-capacity and intelligently managed. Its 0U form factor makes it ideal for installation in standard 19-inch server racks without consuming valuable rack space that would otherwise be used for equipment.
Primary deployment scenarios include data centers, server rooms, and network closets where multiple devices require centralized power distribution with monitoring capabilities. The phase branch level metering is particularly valuable for IT teams managing power capacity across multiple racks or looking to optimize energy usage for cost savings and sustainability initiatives.
Data Center Power Distribution
Distribute 8.64 kW of three-phase power to servers, switches, and storage arrays within a single rack while monitoring consumption at the phase level to prevent overloads and balance loads effectively.
High-Density Server Environments
Support blade servers and other high-power-density equipment with sufficient outlet count and power capacity while maintaining secure access controls and reliable connection retention.
Highlights
- 8.64 kW total power capacity for high-density rack deployments
- 24 NEMA 5-20R outlets support multiple IT devices with standard plugs
- NEMA L21-30P three-phase input connector with 120/208V operation
- 24A input current for efficient power distribution
- 0U rack-mountable design preserves valuable rack space
- Phase branch level metering enables precise load monitoring
- Eaton Hydraulic Magnetic Circuit Breakers with accidental trip protection
- Colour-coded outlet and branch circuits simplify load balancing
- User access control with password protection and SSL encryption
- IEC outlet eGrip plug retention prevents accidental disconnections
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | EMI344-10 |
| Brand Name | Eaton |
| Product Line | ePDU |
| Product Series | Metered |
| Product Model | EMI344-10 |
| Product Name | Metered Input Rack PDU |
| Product Type | PDU |
| Technical Information | |
| Plug/Connector Type | NEMA L21-30P |
| Receptacle Type | NEMA 5-20R |
| Receptacle Detail | 24 x NEMA 5-20R |
| Power Description | |
| Power Rating (Watt) | 8.64 kW |
| Input Current | 24 A |
| Physical Characteristics | |
| Mount Type | Rack-mountable |
| Rack Height | 38U |
| Miscellaneous | |
| Country of Origin | United States |
| Warranty | |
| Limited Warranty | 3 Year |
FAQ
What is the power capacity of this Eaton rack PDU?
The Eaton EMI344-10 provides 8.64 kW of total power capacity, distributed across its 24 outlets. This substantial capacity makes it suitable for powering multiple servers, networking switches, and storage devices within a single rack in data center environments.
How many outlets does this PDU have and what type are they?
This PDU features 24 NEMA 5-20R outlets, which are standard North American receptacles commonly used for IT equipment. The outlet count supports dense rack configurations while the NEMA 5-20R compatibility ensures broad equipment support without requiring adapters.
What type of input connector does this PDU use?
The unit uses a NEMA L21-30P input connector, which is a three-phase locking plug designed for 120/208V power systems. This connector type provides secure, reliable power connection in commercial and data center environments where three-phase power is available.
Is this PDU rack-mountable and what is its form factor?
Yes, this is a 0U rack-mountable PDU designed for vertical installation in standard 19-inch server racks. The 0U form factor means it doesn't consume any rack unit space, preserving all available mounting positions for equipment while providing power distribution along the rack's side or rear.
What monitoring capabilities does this metered input PDU offer?
This Eaton PDU provides phase branch level metering, allowing IT administrators to monitor power consumption at the individual phase level. This detailed monitoring enables precise load balancing across phases, helps prevent circuit overloads, and supports capacity planning for future equipment additions.
What security features are included with this power distribution unit?
The PDU includes user access control with password protection and SSL encryption configurable to 1024 or 2048 bit. These security features prevent unauthorized configuration changes to power settings, ensuring that critical equipment remains protected from accidental or malicious power management alterations.
What power capacity is listed for this UPS?
The listed power specification is 8.64 kW, which helps position the unit for the right load level and installation role.