Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Tripp Lite by Eaton PDU3EVSR10L2130 Eaton 10kW 3-Phase Switched PDU - 24 x C13 - 6 x C19 Outlets - 230V AC - Rack-Mountable 0U
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This switched PDU operates on a three-phase power system with an input voltage of 230V AC and delivers the same output voltage, ensuring stable power distribution without conversion losses. The unit handles a maximum power rating of 10kW with an input current of 24A, making it suitable for powering multiple servers and networking equipment in rack configurations.
Network connectivity is provided through an RJ-45 port, supporting a wide range of management protocols including IPv4, IPv6, HTTP, HTTPS, SNMP versions 1 through 3, telnet, SSH, FTP, DHCP, and NTP. This allows for seamless integration into existing network management systems and remote administration from any location.
This section brings together practical product details such as PDU Type, Design, Phase, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
The PDU3EVSR10L2130 offers significant advantages for data center power management through its combination of high power capacity, granular outlet control, and comprehensive remote monitoring capabilities. The switched functionality allows individual outlet control, enabling administrators to remotely connect or disconnect equipment for maintenance, troubleshooting, or power sequencing without physical access to the rack.
Remote Power Management
Monitor and control individual outlets remotely via network interfaces, providing flexibility for equipment maintenance and power cycling.
- Individual outlet control
- Real-time power monitoring
- Remote reboot capabilities
High-Density Power Distribution
With 30 total outlets (24 C13 and 6 C19), this PDU supports dense server deployments while maintaining proper load balancing.
- 24 C13 outlets for standard equipment
- 6 C19 outlets for high-power devices
- Balanced three-phase distribution
Deployment / Use Cases
This switched PDU is designed for deployment in data centers, server rooms, and network closets where reliable power distribution and remote management are critical. The 0U rack-mountable form factor allows for vertical mounting in standard 19-inch racks, maximizing space utilization while providing power to multiple equipment tiers.
Ideal for environments requiring granular power control, the PDU3EVSR10L2130 supports use cases such as remote data center management, equipment power sequencing, load balancing across server racks, and temporary equipment isolation for maintenance. The three-phase power distribution ensures efficient power delivery for high-density computing environments while the network management capabilities integrate with existing monitoring systems.
Data Center Power Distribution
Distribute three-phase power to multiple server racks with individual outlet monitoring and control for optimal power management.
- Server rack power distribution
- Load balancing across phases
- Remote outlet management
Network Equipment Power
Power networking equipment, switches, and routers with the flexibility to remotely reboot individual devices as needed.
- Network equipment power backup
- Remote troubleshooting capabilities
- Scheduled power cycling
Physical Profile
Designed for vertical rack mounting, this PDU features a compact 0U form factor with dimensions of 70" (1778 mm) height, 2.17" (55.12 mm) width, and 2.86" (72.64 mm) depth. The vertical orientation maximizes rack space utilization while providing easy access to all outlets. Weighing approximately 20.01 lb (9076.38 g), the unit includes plug-lock insert sleeves for secure cable connections and comes with PDUMVROTATEBRKT mounting brackets for flexible installation options.
- Width
- 2.17" (55.12 mm)
- Depth
- 2.86" (72.64 mm)
- Height
- 0U
- Weight
- 20.01 lb (9076.38 g)
What's in the Box
The package includes all necessary components for immediate deployment and operation of the switched PDU system.
Highlights
- 10kW three-phase switched PDU for data center power distribution
- 24 x IEC 60320 C13 and 6 x IEC 60320 C19 outlets for versatile equipment connectivity
- 230V AC input and output voltage with 24A input current
- Network-managed with IPv4, IPv6, HTTP, HTTPS, SNMP, SSH, FTP, DHCP, and NTP support
- 0U rack-mountable design for vertical installation in standard server racks
- Overload protection for equipment safety
- Remote monitoring and individual outlet control capabilities
- Modular design with plug-lock insert sleeves for secure connections
- RoHS compliant and environmentally friendly
- 2-year limited warranty with TAA compliance
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | PDU3EVSR10L2130 |
| Brand Name | Eaton |
| Product Model | PDU3EVSR10L2130 |
| Product Name | PDU3EVSR10L2130 10kW 3-Phase Switched PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Switched |
| Design | Modular |
| Phase | Three Phase |
| Plug/Connector Type | NEMA L21-30P |
| Receptacle Type | IEC 60320 C13,IEC 60320 C19 |
| Receptacle Detail | 24 x IEC 60320 C13,6 x IEC 60320 C19 |
| Protection Type | Overload Protection |
| Power Description | |
| Input Voltage | 230 V AC |
| Output Voltage | 230 V AC |
| Power Rating (Watt) | 10 kW |
| Input Current | 24 A |
| Management | |
| Management | IPv4 IPv6 HTTP HTTPS SMTP SNMPv1 SNMPv2 SNMPv3 telnet SSH FTP DHCP NTP |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Rack Height | 0U |
| Height | 70" (1778 mm) |
| Width | 2.17" (55.12 mm) |
| Depth | 2.86" (72.64 mm) |
| Weight (Approximate) | 20.01 lb (9076.38 g) |
| Miscellaneous | |
| Package Contents | PDU3EVSR10L2130 10kW 3-Phase Switched PDU Built-in LX Platform Interface Configuration Cable 30 x Plug-lock Insert Sleeves Rack-mounting Hardware PDUMVROTATEBRKT Mounting Bracket Accessory Owner's Manual |
| Country of Origin | Taiwan |
| TAA Compliant | Yes |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What is the power capacity of this Eaton PDU?
The Eaton PDU3EVSR10L2130 has a power rating of 10kW (10,000 watts) with 230V AC input and output voltage. This three-phase PDU can distribute up to 10kW of power across its 30 outlets, making it suitable for powering multiple servers and networking equipment in data center environments.
How many outlets does this PDU have and what types are they?
This PDU features 30 total outlets: 24 IEC 60320 C13 outlets for standard equipment and 6 IEC 60320 C19 outlets for high-power devices. The C13 outlets are commonly used for servers, switches, and other IT equipment, while the C19 outlets support higher-current devices that require more robust power connections.
Can this PDU be mounted in a standard server rack?
Yes, the PDU3EVSR10L2130 is designed for vertical rack mounting with a 0U form factor. It includes PDUMVROTATEBRKT mounting brackets and all necessary hardware for installation in standard 19-inch server racks. The vertical orientation maximizes rack space utilization while providing easy access to all outlets.
What network management capabilities does this switched PDU offer?
This switched PDU supports comprehensive network management through multiple protocols including IPv4, IPv6, HTTP, HTTPS, SNMPv1/v2/v3, telnet, SSH, FTP, DHCP, and NTP. This allows for remote monitoring of power usage, individual outlet control, and integration with existing network management systems for centralized power administration.
What type of power input does this PDU require?
The PDU3EVSR10L2130 requires a three-phase power input with a NEMA L21-30P plug connector and operates at 230V AC. It's designed for data center environments with three-phase power distribution and includes overload protection to safeguard connected equipment from power surges or excessive current draw.
What safety and compliance features does this PDU include?
This PDU includes overload protection to prevent damage from excessive current draw and is RoHS (Restriction of Hazardous Substances) compliant. It's also TAA (Trade Agreements Act) compliant for government procurement and comes with a 2-year limited warranty. The unit is manufactured in Taiwan with environmentally friendly materials and processes.
What power capacity is listed for this UPS?
The listed power specification is 10 kW, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 230 V AC, which helps position the unit for the right load level and installation role.