Description

Product Overview

The Middle Atlantic NEXSYS Series 2000VA line-interactive UPS delivers reliable backup power for critical IT and network equipment. This 2U rack/tower unit provides 2 kVA (1.8 kW) of power capacity with automatic voltage regulation (AVR) to correct sags and surges without switching to battery power. Its pure sine wave output ensures compatibility with sensitive electronics, servers, and networking gear.

Designed for deployment in server rooms, network closets, and small office environments, this UPS features eight NEMA 5-20R outlets for direct device connection. The integrated LCD display offers real-time status monitoring, while hot-swappable, user-replaceable lead-acid batteries simplify maintenance. With Energy Star certification and compliance with RoHS and REACH environmental standards, this unit meets modern efficiency and sustainability requirements.

This section brings together practical product details such as AVR, Plug/Connector Type, Receptacle Type, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.

Power
2 kVA
Power Capacity
120 V AC2U
Power Capacity
Load Capacity (VA)2 kVA
Load Capacity (Watt)1.80 kW
Input Voltage120 V AC
Runtime & Battery
Backup Time (Full Load)3 Minute
Backup Time (Half Load)10 Minute
Battery Recharge Time8 Hour
Form Factor & Outlets
Rack Height2U
Form FactorRack/Tower
Receptacles8 x NEMA 5-20R
Management & Connectivity
Network ManagementDry Contact, DB-9 RS-232, SmartSlot, Network Card
InterfacesSerial, USB, Network (RJ-45), EPO Port

Technical Overview

This line-interactive UPS operates with a 120 V AC input voltage, accepting a range from 80 V AC to 145 V AC to handle common power fluctuations. It delivers output at 110 V AC, 120 V AC, or 127 V AC with a 60 Hz pure sine wave, ensuring clean power for active PFC power supplies and sensitive equipment. The 10 ms transfer time provides seamless transition to battery backup during outages.

The 48 V DC battery system uses lead-acid chemistry and supports hot-swappable replacement. Network management capabilities include dry contact, DB-9 RS-232, SmartSlot, and an optional network card for remote monitoring and control. Data line protection via RJ-45 safeguards connected network equipment from surges.

This section brings together practical product details such as AVR, Plug/Connector Type, Receptacle Type, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.

Input Current20 A
Surge Energy Rating1000 J
Sound Emission50 dB(A)
Pure Sine WaveAVRHot Swappable BatteryEnergy Star Certified

Key Product Advantages

The NEXSYS 2000VA UPS combines robust power protection with flexible deployment options. Its automatic voltage regulation maintains stable output during common power sags and surges, extending battery life and reducing wear. The pure sine wave output ensures compatibility with modern server power supplies and sensitive medical or laboratory equipment.

High-Density Outlet Configuration

Eight NEMA 5-20R outlets provide ample connectivity for rack-mounted servers, switches, and other network devices without requiring additional PDUs.

  • Direct device power connection
  • Eliminates need for separate power strip
  • Standard NEMA 5-20P plug compatibility

Comprehensive Management Options

Multiple interface options enable integration with existing monitoring systems and remote management capabilities.

  • Dry contact for simple alarm integration
  • RS-232 for legacy system connectivity
  • SmartSlot for expansion cards
  • Network card for IP-based management

Maintenance-Friendly Design

Hot-swappable batteries allow replacement without powering down connected equipment, minimizing downtime during maintenance cycles.

  • User-replaceable battery modules
  • No service interruption during swaps
  • Typical 8-hour recharge time

Deployment / Use Cases

This UPS is engineered for environments requiring reliable power backup with rack-optimized form factors. Its 2U height fits standard 19-inch server racks while maintaining sufficient power capacity for multiple devices. The rack/tower dual design offers installation flexibility for locations without rack infrastructure.

Typical deployments include network closets supporting switches, routers, and access points; small server rooms with one or two rack-mounted servers; and point-of-sale or medical office environments where power continuity is critical. The 3-minute runtime at full load provides sufficient time for graceful shutdown of connected equipment, while the 10-minute runtime at half load supports extended operation during brief outages.

Server Room & Network Closet Protection

Protects rack-mounted servers, storage arrays, and network switches from power interruptions and voltage fluctuations.

  • 2U rack-optimized design
  • Eight outlets for multiple devices
  • Pure sine wave for server PSU compatibility

Small Office & Retail Environments

Provides backup power for point-of-sale systems, security equipment, and office network infrastructure during outages.

  • Tower configuration for under-desk placement
  • AVR handles building power fluctuations
  • LCD for easy status monitoring

Physical Profile

The black enclosure measures 3.5 inches (88.9 mm) in height, 19 inches (482.6 mm) in width, and 22 inches (558.8 mm) in depth, occupying 2U of rack space. With an approximate weight of 63.05 pounds (28.6 kg), the unit includes integrated mounting hardware for standard 19-inch rack installation. The 5.9-foot (1.8 m) IEC power cord provides sufficient reach to nearby outlets.

Color
Black
Dimensions
Width
19" (482.60 mm)
Depth
22" (558.80 mm)
Height
3.50" (88.90 mm)
Weight
50 dB(A)
Length
5.9 ft (1.80 m)
Dimensions (H x W x D)3.5" x 19" x 22" (88.9 x 482.6 x 558.8 mm)
Weight63.05 lb (28.6 kg)

What's in the Box

The package includes all necessary components for immediate deployment of the UPS system.

NEXSYS 2000VA Rack/tower UPS 6' (1.8m) IEC Power Cord Network Card
NEXSYS 2000VA Rack/tower UPS
[custom-highlights]

Highlights

  • 2000VA/1800W line-interactive UPS with automatic voltage regulation (AVR)
  • Pure sine wave output for compatibility with sensitive electronics and servers
  • Eight NEMA 5-20R outlets for direct device connection
  • 2U rack/tower form factor with standard 19-inch rack mounting
  • 3-minute runtime at full load, 10-minute runtime at half load
  • Hot-swappable, user-replaceable lead-acid batteries
  • LCD display for real-time status and configuration
  • Multiple management interfaces: dry contact, RS-232, SmartSlot, network card
  • Energy Star certified with RoHS and REACH compliance
  • 3-year limited warranty with 2-year battery warranty
[/custom-highlights][custom-specifications]

Specifications

Specifications
ManufacturerLegrand Group
Manufacturer Part NumberUPX-RLNK-2000R-2
Brand NameMiddle Atlantic
Product LineNEXSYS
Product NameNEXSYS Series 2RU 20 Amp UPS Backup Power System with NEXSYS - 2000VA
Product TypeLine-interactive UPS
Technical Information
AVRYes
Plug/Connector TypeNEMA 5-20P
Receptacle TypeNEMA 5-20R
Receptacle Detail8 x NEMA 5-20R
Dataline ProtectionRJ-45
Cord Length5.9 ft (1.80 m)
Transfer Time10 ms
Power Description
Load Capacity (VA)2 kVA
Load Capacity (Watt)1.80 kW
Input Voltage120 V AC
Input Voltage Range80 V AC - 145 V AC
Input Current20 A
Output Voltage110 V AC,120 V AC,127 V AC
Input Frequency60 Hz
Waveform TypePure Sine Wave
Surge Energy Rating1000 J
Display & Graphics
DisplayLCD
Management
Network ManagementDry Contact,DB-9 RS-232,SmartSlot,Network Card
Interfaces/Ports
Serial PortYes
USBYes
Network (RJ-45)Yes
EPO PortYes
Battery Information
DC System Voltage48 V DC
Battery ChemistryLead Acid
Backup/Run Time (Full Load)3 Minute
Backup/Run Time (Half Load)10 Minute
Hot SwappableYes
Typical Battery Recharge Time8 Hour
Replaceable BatteryYes
Environmental Conditions
Maximum Operating Elevation9842.52 ft (3000000 mm)
Storage Temperature5°F (-15°C) - 113°F (45°C)
Operating Humidity95%
Minimum Operating Temperature32°F (0°C)
Maximum Operating Temperature104°F (40°C)
Sound Emission (A-Weighted)50 dB(A)
Physical Characteristics
Product ColorBlack
Height3.50" (88.90 mm)
Width19" (482.60 mm)
Depth22" (558.80 mm)
Rack Height2U
Form FactorRack/Tower
Weight (Approximate)63.05 lb (28600 g)
Miscellaneous
Package ContentsNEXSYS 2000VA Rack/tower UPS 6' (1.8m) IEC Power Cord Network Card
Energy StarYes
Country of OriginChina
Environmentally FriendlyYes
Environmental ComplianceRegistration, Evaluation, Authorization and Restriction of Chemicals (REACH),Restriction of Hazardous Substances (RoHS)
Warranty
Limited Warranty3 Year
Additional Warranty Information2 Years Battery
[/custom-specifications][custom-user-manual]

User Manual

This section contains official documentation provided by the manufacturer, including product manuals, brochures, and supplementary materials.
[/custom-user-manual][custom-faq]

FAQ

What is the power capacity of this UPS?

This Middle Atlantic NEXSYS Series UPS provides 2000 VA (2 kVA) of apparent power and 1800 watts of real power capacity. It operates on 120 V AC input with 20 A current, delivering output at 110 V AC, 120 V AC, or 127 V AC. The unit includes automatic voltage regulation to handle input fluctuations between 80 V AC and 145 V AC without switching to battery power.

How many devices can I connect to this UPS?

The UPS features eight NEMA 5-20R receptacles, allowing direct connection of up to eight devices with standard NEMA 5-20P plugs. This outlet configuration supports typical rack-mounted equipment like servers, switches, and storage devices without requiring additional power distribution units. The 20 A input current and 1800 W capacity determine the total connected load rather than the outlet count alone.

What is the battery runtime during a power outage?

At full load (1800 watts), the UPS provides approximately 3 minutes of battery runtime. At half load (900 watts), runtime extends to approximately 10 minutes. These runtimes allow sufficient time for connected equipment to perform graceful shutdowns or continue operation through brief outages. The lead-acid batteries typically recharge within 8 hours after being depleted.

Can this UPS be installed in a server rack?

Yes, this UPS is designed for both rack and tower deployment. The 2U height (3.5 inches) fits standard 19-inch server racks, with dimensions of 19 inches wide and 22 inches deep. It includes mounting hardware for rack installation. The rack/tower dual form factor provides flexibility for environments without rack infrastructure, allowing the unit to be placed on the floor or under desks when needed.

What management and monitoring options are available?

The UPS offers multiple management interfaces: dry contact for simple alarm integration, DB-9 RS-232 for legacy system connectivity, a SmartSlot for expansion cards, and support for an optional network card for IP-based management. The front-panel LCD display provides real-time status information including input/output voltage, battery charge level, and load percentage. USB and network (RJ-45) ports enable connection to monitoring software.

Are the batteries user-replaceable?

Yes, the lead-acid batteries are hot-swappable and user-replaceable. This design allows battery replacement without powering down connected equipment, minimizing downtime during maintenance. The batteries typically require replacement every 3-5 years depending on usage patterns and environmental conditions. The UPS includes a 2-year battery warranty in addition to the 3-year limited warranty on the unit itself.

What power capacity is listed for this UPS?

The listed power specification is 2 kVA, which helps position the unit for the right load level and installation role.

What voltage details are listed?

The listed power specification is 120 V AC, which helps position the unit for the right load level and installation role.

[/custom-faq]
Volume Discounts
Qty Price Available
Match Price Request

Found a lower price? Send us the link and we will do our best to match or beat it.

Request received. We will reply within 24 hours.
Fleet Network
Wholesale & B2B
Partner with Us

Looking to buy in bulk? We offer competitive pricing, dedicated support, and custom solutions for businesses of all sizes.

Volume Discounts

Tiered pricing structure designed to maximize your margins as you grow.

Dedicated Account Manager

Direct access to a specialist who understands your business needs.

Fast & Reliable Shipping

Priority processing and discounted shipping rates for bulk orders.

Request a Quote
Thank you!
Your request has been sent successfully.
Middle Atlantic UPX-RLNK-2000R-2 NEXSYS Series 2000VA Line-Interactive UPS - 2U Rack/Tower - 8 Outlets - AVR - Pure Sine Wave - 3-Minute Full-Load
MSRP: $4,484.45
$4,484.45
$2,941.99
Save: $1,542.46 (34.40%)
Out of stock