Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Middle Atlantic UPS-OL2200R Premium Online Series 2200VA/1800W 2U Rack-mountable UPS - 120V AC - 7 Min Full Load Runtime - 5 Hour Recharge
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This double conversion online UPS features a 0 ns transfer time, providing uninterrupted power by continuously converting AC input to DC and back to clean AC output. The pure sine wave output maintains compatibility with active PFC power supplies and sensitive equipment, while the EMI/RFI noise filter and overload protection safeguard connected devices. Input voltage operates from 100 V AC to 125 V AC at 60 Hz, with output adjustable between 100 V AC and 125 V AC to match load requirements.
The battery system comprises six 12V, 9000 mAh sealed lead-acid batteries, delivering a DC system voltage of 72 V DC. Hot-swappable design allows battery replacement without powering down connected equipment, and the typical recharge time is 5 hours. Management interfaces include a serial port and USB HID-compliant port for remote monitoring and control, supporting integration with network management software.
Key Product Advantages
The UPS-OL2200R excels in environments demanding high availability and power quality. Its double conversion topology isolates connected equipment from grid anomalies like sags, surges, and harmonics, ensuring stable operation. The extensive receptacle configuration includes six NEMA 5-20R and one NEMA L5-20R outlets, accommodating a variety of North American plug types for flexible device connectivity.
Advanced Monitoring
The multi-function LCD readout supports 19 types of readouts, 22 function settings, and 5 event logs, providing detailed insights into power conditions and system health.
- Real-time voltage/frequency display
- Battery status and runtime estimation
- Configurable alarm thresholds
Robust Protection
Integrated dataline protection for RJ-11/RJ-45 connections safeguards network and telecom equipment from power surges induced through data lines.
- EMI/RFI noise filtering
- Overload and short-circuit protection
- Automatic voltage regulation
Deployment / Use Cases
Ideal for rack-mounted IT infrastructure, the UPS-OL2200R supports servers, storage arrays, networking gear, and telecommunications systems in data centers and server rooms. Its 7-minute runtime at full load provides sufficient time for graceful shutdowns or transfer to backup generators during extended outages, protecting critical data and preventing hardware damage.
In industrial and commercial settings, this UPS secures process control systems, medical equipment, and security installations where power continuity is non-negotiable. The 2U form factor maximizes rack space efficiency, while the 39.6 lb weight and standard 19-inch width ensure straightforward installation in existing racks. Deployment scenarios include edge computing locations, broadcast facilities, and financial trading floors where uptime directly impacts operational integrity.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Physical Profile
Designed for standard 19-inch racks, the UPS-OL2200R occupies 2U of vertical space with dimensions of 3.46 inches in height, 19 inches in width, and 22.26 inches in depth. The black finish blends with typical rack hardware, and the front-panel LCD and LED indicators provide at-a-glance status without requiring additional monitoring tools. The unit's weight of 39.60 pounds ensures stable mounting, and the included 10-foot power cord simplifies integration into existing power distribution setups.
- Width
- 19" (482.60 mm)
- Depth
- 22.26" (565.40 mm)
- Height
- 3.46" (87.88 mm)
- Weight
- 50 dB(A)
What's in the Box
The package includes the 2 RU Premium Online Series UPS backup power unit (2200VA) and a 10-foot power cord, providing everything needed for immediate deployment into a rack environment.
Highlights
- 2200VA/1800W double conversion online UPS for mission-critical equipment
- 2U rack-mountable design fits standard 19-inch server racks
- Pure sine wave output ensures compatibility with sensitive electronics
- 7-minute runtime at full load, 20 minutes at half load
- Hot-swappable, maintenance-free batteries for easy replacement
- Multi-function LCD with real-time monitoring and event logging
- Six NEMA 5-20R and one NEMA L5-20R outlets for flexible connectivity
- Serial and USB ports for remote management and monitoring
- 0 ns transfer time provides uninterrupted power during outages
- 3-year limited warranty with 2-year battery warranty
Specifications
| Specifications | |
|---|---|
| Manufacturer | Legrand Group |
| Manufacturer Part Number | UPS-OL2200R |
| Brand Name | Middle Atlantic |
| Product Line | Premium Online |
| Product Model | UPS-OL2200R |
| Product Name | 2RU Premium Online Series 20 Amp UPS Backup Power - 2200VA - Black |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | NEMA 5-20P |
| Receptacle Type | NEMA 5-20R,NEMA L5-20R |
| Receptacle Detail | 6 x NEMA 5-20R,1 x NEMA L5-20R |
| Dataline Protection | RJ-11/RJ-45 |
| Overload Protection | Yes |
| Transfer Time | 0 ns |
| EMI/RFI Noise Filter | Yes |
| Application/Usage | Mission Critical Equipment,High-end System |
| Power Description | |
| Load Capacity (VA) | 2.20 kVA |
| Load Capacity (Watt) | 1.80 kW |
| Input Voltage | 120 V AC |
| Input Voltage Range | 100 V AC - 125 V AC |
| Output Voltage | 100 V AC,110 V AC,115 V AC,120 V AC,125 V AC |
| Input Frequency | 60 Hz |
| Output Frequency | 60 Hz |
| Waveform Type | Pure Sine Wave |
| Management | |
| Alarm | Battery,Low Battery,Overload,UPS Fault |
| Controls/Indicators | |
| Status Indicators | LCD Screen Multi-Function LCD Readout that Supports: (19) Types of Read Out, (22) Types of Function Setting, (5) Event Logs LED Indicators Power On (White), Line Mode (Green), Battery Mode (Yellow), Bypass Mode (Yellow), Fault (Red), Replace Battery (Red) |
| Interfaces/Ports | |
| Serial Port | Yes |
| USB (HID Compliant) Port | Yes |
| Battery Information | |
| DC System Voltage | 72 V DC |
| Number of Batteries | 6 |
| Battery Characteristics | Maintenance-free, Sealed |
| Battery Size | 12V |
| Battery Capacity | 9000 mAh |
| Backup/Run Time (Full Load) | 7 Minute |
| Backup/Run Time (Half Load) | 20 Minute |
| Hot Swappable | Yes |
| Typical Battery Recharge Time | 5 Hour |
| Replaceable Battery | Yes |
| Environmental Conditions | |
| Storage Relative Humidity | 0% - 90% |
| Maximum Operating Temperature | 104°F (40°C) |
| Sound Emission (A-Weighted) | 50 dB(A) |
| Thermal Dissipation | 736 BTU/h |
| Physical Characteristics | |
| Product Color | Black |
| Height | 3.46" (87.88 mm) |
| Width | 19" (482.60 mm) |
| Depth | 22.26" (565.40 mm) |
| Rack Height | 2U |
| Form Factor | Rack-mountable |
| Weight (Approximate) | 39.60 lb (17962.26 g) |
| Miscellaneous | |
| Package Contents | 2 RU Premium Online Series UPS Backup Power, 2200VA 10' Power Cord |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 3 Year |
| Additional Warranty Information | Battery shall be warrantied for a period of 2 years |
FAQ
What is the power capacity of the Middle Atlantic UPS-OL2200R?
The UPS-OL2200R offers a load capacity of 2.20 kVA (2200VA) and 1.80 kW (1800W). This capacity supports critical equipment like servers, networking gear, and storage systems, providing sufficient backup power during outages to allow for safe shutdowns or transition to alternate power sources.
How long does the battery last during a power outage?
At full load, the battery provides up to 7 minutes of runtime, while at half load, runtime extends to approximately 20 minutes. These durations offer adequate time for orderly system shutdowns or activation of backup generators, protecting data integrity and hardware from abrupt power loss.
What type of output waveform does this UPS produce?
This UPS delivers a pure sine wave output, which is essential for compatibility with active power factor correction (PFC) power supplies found in modern servers, network equipment, and sensitive electronics. Pure sine wave power ensures stable operation and prevents potential damage or malfunctions that can occur with simulated sine wave outputs.
Is the battery hot-swappable?
Yes, the UPS-OL2200R features hot-swappable batteries, allowing you to replace battery modules without powering down connected equipment. This design minimizes downtime and maintains continuous power protection, which is crucial for environments where uptime is critical, such as data centers or industrial control systems.
What management interfaces are available?
The UPS includes both a serial port and a USB HID-compliant port for management. These interfaces enable remote monitoring, configuration, and integration with network management software, allowing administrators to track power status, receive alerts, and automate shutdown procedures across connected systems.
What is the recharge time for the batteries?
The typical battery recharge time is 5 hours after a complete discharge. This relatively quick recharge ensures the UPS is ready to handle subsequent outages, and the hot-swappable design allows for battery maintenance or replacement without interrupting power to connected devices.
What power capacity is listed for this UPS?
The listed power specification is 2.20 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 120 V AC, which helps position the unit for the right load level and installation role.