Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Minuteman EC3000RT2UNC Ecompass 3000VA Double Conversion Online UPS - 2. 70 kW - 2U Rack/Tower - 6 NEMA Outlets - 120V AC - 3 Minute Runtime
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This double conversion online UPS continuously conditions incoming power, providing isolation from utility line anomalies. The 120 V AC sine wave output ensures stable operation for servers, networking gear, and other critical loads.
With a 3 kVA (3000VA) capacity and 2.70 kW wattage rating, it can support substantial equipment configurations. The 2U rack height and 18.90" width allow standard rack integration, while the tower configuration offers standalone placement flexibility.
This section brings together practical product details such as Receptacle Type, Receptacle Detail, Load Capacity (VA), Load Capacity (Watt), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
These strengths make the product easier to deploy and manage in real environments, especially where reliability, usability, and day-to-day operational continuity matter. Notable benefits include Double Conversion Protection, Flexible Deployment, Management Ready.
Double Conversion Protection
Provides complete isolation from power line disturbances, including surges, sags, and frequency variations, ensuring clean power delivery to connected equipment.
Flexible Deployment
The rack/tower convertible design supports both 19" rack mounting and standalone tower placement, adapting to various IT environments without requiring separate hardware.
Management Ready
Includes SentryHD software and supports an optional SNMP card for remote monitoring and management, enabling proactive power management in networked environments.
Deployment / Use Cases
This UPS is engineered for environments where power quality and uptime are critical. Its 3000VA capacity makes it suitable for protecting small server clusters, network infrastructure, or workstations in offices, retail locations, or light industrial settings.
The 2U rack-mountable form factor is ideal for standard server racks in data closets or server rooms, while the tower configuration works well for under-desk or standalone installations. With six NEMA outlets, it can power multiple devices simultaneously, reducing the need for additional power distribution units.
This section brings together practical product details such as Receptacle Type, Receptacle Detail, Load Capacity (VA), Load Capacity (Watt), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Physical Profile
The EC3000RT2UNC measures 3.50" in height (88.90 mm) and 18.90" in width (480.06 mm), with a 2U rack height specification for standard 19" rack compatibility. At approximately 60.50 pounds (27442.34 g), it's substantial enough for stable rack mounting while remaining manageable for installation.
The rack/tower convertible design includes necessary hardware for both installation methods, with a form factor that balances power density with accessibility for maintenance and cable management.
- Width
- 18.90" (480.06 mm)
- Height
- 3.50" (88.90 mm)
- Weight
- 60.50 lb (27442.34 g)
What's in the Box
The package includes everything needed for immediate deployment of the UPS system.
Highlights
- 3000VA/2.70 kW double conversion online UPS for critical power protection
- 2U rack/tower convertible form factor for flexible deployment options
- Six NEMA 5-15/20R outlets to support multiple connected devices
- 3-minute runtime at full load to handle brief power interruptions
- Pure sine wave output ensures compatibility with sensitive electronics
- Includes SentryHD software for local monitoring and management
- Supports optional SNMP card for remote network management
- 3-year limited warranty for long-term reliability assurance
- Environmentally friendly design and manufacturing
- Made in China with global quality standards
Specifications
| Specifications | |
|---|---|
| Manufacturer | Para Systems, Inc |
| Manufacturer Part Number | EC3000RT2UNC |
| Brand Name | Minuteman |
| Product Line | Ecompass |
| Product Model | EC3000RT2UNC |
| Product Name | Ecompass EC3000RT2UNC 3000VA Tower/Rack Mountable UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Receptacle Type | NEMA 5-15/20R |
| Receptacle Detail | 6 x NEMA 5-15/20R |
| Power Description | |
| Load Capacity (VA) | 3 kVA |
| Load Capacity (Watt) | 2.70 kW |
| Output Voltage | 120 V AC |
| Waveform Type | Sine Wave |
| Battery Information | |
| Backup/Run Time (Full Load) | 3 Minute |
| Physical Characteristics | |
| Height | 3.50" (88.90 mm) |
| Width | 18.90" (480.06 mm) |
| Rack Height | 2U |
| Form Factor | Rack/Tower |
| Weight (Approximate) | 60.50 lb (27442.34 g) |
| Miscellaneous | |
| Package Contents | Ecompass EC3000RT2UNC 3000VA Tower/Rack Mountable UPS Battery SentryHD Software SNMP Card |
| Country of Origin | China |
| Environmentally Friendly | Yes |
| Warranty | |
| Limited Warranty | 3 Year |
FAQ
What is the power capacity of this Minuteman UPS?
The Minuteman EC3000RT2UNC provides 3000VA (3 kVA) of apparent power and 2700 watts (2.70 kW) of real power capacity. This rating indicates it can support equipment drawing up to 2700 watts continuously, making it suitable for small server setups, network equipment, or multiple workstations.
How long will this UPS run at full load during a power outage?
At full 2700-watt load, this UPS provides approximately 3 minutes of runtime. This duration allows for graceful shutdown of connected equipment or bridging brief power interruptions. Runtime increases significantly at lower loads, providing more extended protection for typical usage scenarios.
Can this UPS be mounted in a standard server rack?
Yes, the EC3000RT2UNC is designed for 2U rack mounting in standard 19" server racks. It measures 3.50" in height (88.90 mm) and 18.90" in width (480.06 mm), with all necessary mounting hardware included. The unit also converts to tower configuration for standalone placement where rack mounting isn't available.
What type of power outlets does this UPS have?
This UPS features six NEMA 5-15/20R receptacles, which are standard North American outlets supporting both 5-15 and 5-20 plug configurations. These outlets provide 120V AC power and are suitable for most office and IT equipment, allowing you to connect multiple devices directly to the UPS.
What is double conversion online topology and why is it important?
Double conversion online topology continuously converts incoming AC power to DC, then back to clean AC output. This provides complete isolation from utility power issues like surges, sags, spikes, and frequency variations. It's the highest level of UPS protection, ensuring connected equipment always receives clean, stable power regardless of input quality.
What management capabilities does this UPS include?
The UPS includes SentryHD software for local monitoring and management via USB connection. It also supports an optional SNMP card (included in the package) for network-based monitoring, allowing remote management of power status, configuration, and alerts through standard network management systems.
What power capacity is listed for this UPS?
The listed power specification is 3 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 120 V AC, which helps position the unit for the right load level and installation role.