Minuteman EC3000RT2U Encompass 3000VA Double Conversion Online UPS - 2. 7kW - 2U Rack/Tower - 120V AC - 3 Minute Runtime
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This double conversion online UPS topology provides complete isolation from utility power, delivering consistent 120V AC output regardless of input fluctuations within a 0-160V AC range. The 3 kVA/2.70 kW capacity supports mixed equipment loads typical in network infrastructure, from servers and switches to security system controllers. Sine wave output guarantees safe operation for active PFC power supplies found in modern computing gear.
The electrical design includes seven outlets: one NEMA L5-30R for high-draw equipment and six NEMA 5-15/20R receptacles for standard devices. Input protection handles brownouts and overvoltage conditions while maintaining clean power delivery. Battery management extends cell life through temperature-compensated charging and automatic self-test routines that verify readiness without manual intervention.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
The EC3000RT2U combines enterprise-grade power protection with deployment flexibility that suits both rack-mounted and tower installations. Its 2U height optimizes rack space while the substantial 3 kVA capacity handles demanding network loads without compromise.
Zero Transfer Time Protection
Double conversion technology eliminates transfer delays during power events, providing seamless backup that prevents even momentary interruptions to connected equipment.
Flexible Installation Options
Mount vertically in standard 19-inch racks using included hardware or operate as a standalone tower with stable footprint design for office environments.
Maintenance Without Downtime
Hot-swappable battery modules enable replacement during normal operation, eliminating scheduled downtime for battery maintenance cycles.
Deployment / Use Cases
This UPS serves as primary protection for network infrastructure where power quality directly impacts uptime. The 3-minute runtime at full load provides sufficient buffer for short outages while allowing controlled shutdown during extended power failures.
Typical deployments include server racks supporting business applications, network closets with switches and routers, and security systems with DVRs and access control panels. The outlet mix accommodates both high-wattage servers via the L5-30R connection and lower-power devices like modems and cameras through standard outlets.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Network Closet Protection
Safeguard switches, routers, and VoIP equipment from power fluctuations that cause network instability and data corruption.
Security System Backup
Maintain surveillance camera recording, access control systems, and alarm panels during utility outages to ensure continuous security monitoring.
Physical Profile
The unit measures 3.5" (88.90 mm) in height, 18.9" (480.06 mm) in width, and occupies 2U of vertical rack space. At 59.5 pounds, it provides substantial power density in a compact form factor. The rack-mount design includes front panel status indicators and controls for easy monitoring in data center environments, while the tower configuration offers stable placement on floors or shelves with ventilation considerations.
- Width
- 18.90" (480.06 mm)
- Height
- 3.50" (88.90 mm)
- Weight
- 59.50 lb (26988.75 g)
What's in the Box
The package includes all components needed for immediate deployment in either rack or tower configuration.
Highlights
- 3000VA/2.7kW double conversion online UPS with pure sine wave output
- 2U rack/tower form factor for flexible deployment in server rooms or offices
- 3-minute runtime at full load for graceful shutdown during power outages
- Seven outlets: one NEMA L5-30R and six NEMA 5-15/20R receptacles
- Hot-swappable battery enables maintenance without system downtime
- 120V AC input/output with 0-160V AC input range for brownout protection
- Energy Star certified for efficient power usage
- 3-year limited warranty for long-term reliability
- RoHS 2 compliant for reduced environmental impact
- Designed for network closet, security system, and server applications
Specifications
| Specifications | |
|---|---|
| Manufacturer | Para Systems, Inc |
| Manufacturer Part Number | EC3000RT2U |
| Brand Name | Minuteman |
| Product Line | Encompass |
| Product Model | EC3000RT2U |
| Product Name | Encompass EC3000RT2U 3000VA Tower/Rack Mountable UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | NEMA L5-30P |
| Receptacle Type | NEMA L5-30R,NEMA 5-15/20R |
| Receptacle Detail | 1 x NEMA L5-30R,6 x NEMA 5-15/20R |
| Application/Usage | Network Closet,Security System,Network |
| Power Description | |
| Load Capacity (VA) | 3 kVA |
| Load Capacity (Watt) | 2.70 kW |
| Input Voltage | 120 V AC |
| Input Voltage Range | 0 V AC - 160 V AC |
| Output Voltage | 120 V AC |
| Waveform Type | Sine Wave |
| Battery Information | |
| Backup/Run Time (Full Load) | 3 Minute |
| Hot Swappable | Yes |
| Physical Characteristics | |
| Height | 3.50" (88.90 mm) |
| Width | 18.90" (480.06 mm) |
| Rack Height | 2U |
| Form Factor | Rack/Tower |
| Weight (Approximate) | 59.50 lb (26988.75 g) |
| Miscellaneous | |
| Package Contents | Encompass EC3000RT2U 3000VA Tower/Rack Mountable UPS Battery |
| Energy Star | Yes |
| Country of Origin | China |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) 2 |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the power capacity of this UPS?
The Minuteman EC3000RT2U provides 3000VA (3 kVA) of apparent power and 2700 watts (2.7 kW) of real power capacity. This dual rating ensures compatibility with both VA-based sizing for traditional equipment and watt-based calculations for modern power supplies with power factor correction.
How long will this UPS run at full load?
At maximum 2.7 kW load, the UPS delivers approximately 3 minutes of runtime. This provides sufficient time for connected systems to complete critical operations, save data, and initiate controlled shutdown procedures during power interruptions.
What types of outlets does this UPS have?
The unit features seven total outlets: one NEMA L5-30R receptacle for high-power equipment like servers, and six NEMA 5-15/20R receptacles for standard devices such as switches, routers, and security system components. This mixed configuration supports diverse equipment loads in typical deployments.
Can this UPS be mounted in a server rack?
Yes, the EC3000RT2U is designed for both rack and tower installation. It occupies 2U of vertical space in standard 19-inch server racks and includes necessary mounting hardware. The compact 3.5-inch height optimizes rack space utilization while providing substantial power capacity.
What is double conversion online topology?
Double conversion online technology continuously converts incoming AC power to DC, then back to clean AC output. This provides complete isolation from utility power irregularities, zero transfer time during outages, and consistent voltage regulation regardless of input fluctuations within the 0-160V AC operating range.
Is the battery hot-swappable?
Yes, the battery modules are hot-swappable, allowing replacement while the UPS continues to provide power to connected equipment. This feature eliminates downtime for battery maintenance and enables proactive replacement before end-of-life failure impacts system availability.
What power capacity is listed for this UPS?
The listed power specification is 3 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 120 V AC, which helps position the unit for the right load level and installation role.