Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Minuteman ED10000RTXL Endeavor 8889VA Rack/Tower UPS - 9U Double Conversion Online - 208V Input - 4 Min Full Load Runtime
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This double conversion online UPS maintains consistent power quality by continuously converting incoming AC to DC and back to clean AC, isolating connected equipment from grid anomalies. The 8.89 kVA capacity supports substantial loads, with runtime specifications of 4 minutes at full load and 12 minutes at half load, providing critical time for orderly shutdowns or generator transition.
The unit accepts 208V AC input at 70 Hz and delivers output at 208V, 212V, or 120V AC with a stable 60 Hz frequency. Hardwired connectivity ensures secure power delivery, while the receptacle configuration includes one NEMA L6-20R, one NEMA L6-30R, and eight NEMA 5-15/20R outlets for versatile equipment connection.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
The Endeavor ED10000RTXL combines industrial-grade power protection with flexible deployment options, making it suitable for environments where power reliability is non-negotiable. Its double conversion topology ensures maximum protection against all types of power disturbances, while the substantial battery capacity provides meaningful runtime for critical systems.
Deployment Flexibility
The 9U rack/tower design allows installation in standard server racks or as a standalone tower, adapting to various space constraints and infrastructure requirements.
- 9U rack height
- Tower conversion kit included
- 17.30" width fits standard racks
Advanced Power Management
SNMP manageability enables remote monitoring and control through network management systems, while the included operating system shutdown software automates safe system power-down during extended outages.
- SNMP for network integration
- Serial port for local management
- Automatic shutdown capability
Compliance & Efficiency
Energy Star certification confirms energy-efficient operation, while RoHS 2 compliance ensures environmentally responsible manufacturing with restricted hazardous substances.
- Energy Star certified
- RoHS 2 compliant
- 3-year warranty coverage
Deployment / Use Cases
The ED10000RTXL is engineered for commercial and industrial applications where power quality and uptime are critical. Its 8.89 kVA capacity and multiple voltage outputs make it suitable for protecting server racks, network equipment, industrial controls, and other sensitive electronic systems.
In data center environments, this UPS provides clean power to server racks while the rack-mount design optimizes floor space. For industrial settings, the tower configuration offers standalone protection for control systems, with the hardwired connection ensuring secure power delivery to critical machinery.
Data Center Protection
Protect server racks and network infrastructure with clean, regulated power and sufficient runtime for orderly shutdown or backup generator activation.
Industrial Control Systems
Safeguard PLCs, HMIs, and control equipment from power disturbances that could disrupt manufacturing processes or damage sensitive electronics.
Physical Profile
The ED10000RTXL occupies 9U of rack space with dimensions of 17.30" wide × 15.42" high × 25.90" deep (439.42 × 391.67 × 657.86 mm), fitting standard 19" server racks. At 434 pounds (196.86 kg), this substantial unit requires proper rack reinforcement or stable floor placement for tower deployment. The included rail kit and foot brackets facilitate secure installation in either configuration.
- Width
- 17.30" (439.42 mm)
- Depth
- 25.90" (657.86 mm)
- Height
- 9U
- Weight
- 434 lb (196859.09 g)
What's in the Box
The package includes all necessary components for immediate deployment in rack or tower configurations.
Highlights
- 8.89 kVA double conversion online UPS for maximum power protection
- 9U rack/tower form factor with included conversion hardware
- 208V AC input with 208V, 212V, and 120V AC output options
- 4-minute runtime at full load, 12 minutes at half load
- Hardwired with NEMA L6-20R, L6-30R, and eight NEMA 5-15/20R outlets
- SNMP manageable for remote monitoring and control
- Energy Star certified and RoHS 2 compliant
- 3-year limited warranty for long-term reliability assurance
Specifications
| Specifications | |
|---|---|
| Manufacturer | Para Systems, Inc |
| Manufacturer Part Number | ED10000RTXL |
| Brand Name | Minuteman |
| Product Line | Endeavor |
| Product Model | ED10000RTXL |
| Product Name | Endeavor ED10000RTXL 8889VA Rack/Tower UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | Hardwired |
| Receptacle Type | NEMA L6-20R,NEMA L6-30R,NEMA 5-15/20R |
| Receptacle Detail | 1 x NEMA L6-20R,1 x NEMA L6-30R,8 x NEMA 5-15/20R |
| Overload Protection | Yes |
| Power Description | |
| Load Capacity (VA) | 8.89 kVA |
| Input Voltage | 208 V AC |
| Output Voltage | 208 V AC,212 V AC,120 V AC |
| Input Frequency | 70 Hz |
| Output Frequency | 60 Hz |
| Management | |
| Network Management | SNMP Manageable |
| Interfaces/Ports | |
| Serial Port | Yes |
| Battery Information | |
| Backup/Run Time (Full Load) | 4 Minute |
| Backup/Run Time (Half Load) | 12 Minute |
| Physical Characteristics | |
| Form Factor | Rack/Tower |
| Rack Height | 9U |
| Height | 15.42" (391.67 mm) |
| Width | 17.30" (439.42 mm) |
| Depth | 25.90" (657.86 mm) |
| Weight (Approximate) | 434 lb (196859.09 g) |
| Miscellaneous | |
| Package Contents | Endeavor ED10000RTXL 8889VA Rack/Tower UPS Rail kit Foot Brackets Battery Pack Transformer |
| Software Included | Operating System Shutdown |
| Energy Star | Yes |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) 2 |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the power capacity of the Minuteman ED10000RTXL UPS?
The Minuteman ED10000RTXL has a load capacity of 8.89 kVA (8889 VA), making it suitable for protecting substantial equipment loads in commercial and industrial environments. This double conversion online UPS can support connected devices drawing up to this capacity while providing clean, regulated power output.
How long will this UPS run on battery power?
At full load (8.89 kVA), the ED10000RTXL provides 4 minutes of runtime, while at half load (approximately 4.445 kVA), it delivers 12 minutes of backup power. These runtime specifications allow sufficient time for orderly system shutdowns or transition to backup generators during power outages.
What input and output voltages does this UPS support?
This UPS accepts 208V AC input at 70 Hz and provides output at three voltage options: 208V AC, 212V AC, or 120V AC, all at a stable 60 Hz frequency. The multiple output voltages allow compatibility with various equipment types and voltage requirements within the same protected system.
Can this UPS be installed in a server rack?
Yes, the ED10000RTXL is designed for both rack and tower installations. It occupies 9U of rack space with dimensions of 17.30" wide × 15.42" high × 25.90" deep, fitting standard 19" server racks. The package includes a rail kit for secure rack mounting and foot brackets for tower configuration.
What management capabilities does this UPS offer?
The ED10000RTXL is SNMP manageable, allowing remote monitoring and control through network management systems. It also includes a serial port for local management and comes with operating system shutdown software that automates safe system power-down during extended power outages.
What type of outlets does this UPS have?
This hardwired UPS features a combination of NEMA outlets: one L6-20R, one L6-30R, and eight 5-15/20R receptacles. This configuration provides versatile connectivity options for different equipment types, from high-power devices to standard electronics, with a total of ten protected outlets.
What power capacity is listed for this UPS?
The listed power specification is 8.89 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 208 V AC, which helps position the unit for the right load level and installation role.