Minuteman ED10KRT-3KTF Endeavor 10000VA Rack/Tower UPS - 5U Double Conversion Online - 8. 87 kW - Pure Sine Wave
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This double conversion online UPS continuously converts incoming AC power to DC and back to AC, isolating connected equipment from power anomalies like surges, sags, and frequency variations. The 10 kVA/8.87 kW capacity supports substantial loads, and the pure sine wave output guarantees clean power for critical infrastructure.
Runtime is configurable based on load: at full load, the unit provides 2 minutes of backup, while at half load, runtime extends to 7 minutes. The hot-swappable battery design allows for maintenance without system shutdown, and the replaceable battery ensures long-term serviceability.
This section brings together practical product details such as Plug/Connector Type, Protection Type, Phase, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The Endeavor ED10KRT-3KTF combines high power capacity with operational flexibility, making it a robust choice for protecting mission-critical systems. Its double conversion topology ensures zero transfer time during power failures, while the wide output voltage selection accommodates diverse equipment requirements.
High-Efficiency Operation
With 93% efficiency, this UPS reduces energy waste and heat generation, lowering total cost of ownership and supporting sustainable IT operations.
- ENERGY STAR 2.0 certified
- Reduces cooling demands in server rooms
Flexible Deployment Options
The rack/tower form factor and 5U height allow installation in standard server racks or as a standalone tower, adapting to space constraints and infrastructure layouts.
- Fits 19-inch server racks
- Sturdy construction for tower use
Advanced Management Capabilities
RS-232 and USB ports enable remote monitoring and control, while the EPO port supports emergency shutdown procedures for enhanced safety in data centers.
- Compatible with network management systems
- Integrates with existing power management software
Deployment / Use Cases
This UPS is designed for environments where power quality and uptime are non-negotiable. Its 10 kVA capacity and double conversion technology make it suitable for protecting server racks, network closets, and telecommunications equipment from power disturbances.
In large enterprise or corporate settings, the unit safeguards VoIP systems, security infrastructure, and industrial controls. The hardwired connection and wide input voltage range ensure reliable performance in facilities with unstable utility power, while the hot-swappable batteries simplify maintenance in 24/7 operations.
This section brings together practical product details such as Plug/Connector Type, Protection Type, Phase, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Data Center Server Protection
Provides clean, uninterrupted power to rack-mounted servers and storage arrays, preventing data loss and hardware damage during outages.
Network and Telecommunications
Supports VoIP systems, switches, and routers in telecommunication hubs, ensuring continuous connectivity and service availability.
Physical Profile
The UPS measures 11.95 inches in height and 17.24 inches in width, with a weight of approximately 258.97 pounds. The 5U rack height fits standard server cabinets, and the robust construction supports tower deployment where rack space is unavailable. The unit operates in temperatures up to 104°F and humidities from 0% to 95%, making it suitable for controlled server rooms and industrial environments.
- Width
- 17.24" (437.90 mm)
- Height
- 5U
- Weight
- 258.97 lb (117466.82 g)
What's in the Box
The package includes the Endeavor ED10KRT-3KTF 10000VA Rack/Tower UPS and necessary communication cables for setup and management.
Package contents include Endeavor ED10KRT-3KTF 10000VA Rack/Tower UPS Comm. Cables, Endeavor ED10KRT-3KTF 10000VA Rack/Tower UPS. These included items support setup, installation, and immediate deployment without needing to source the core bundled accessories separately.
Highlights
- 10000VA/8.87 kW double conversion online UPS for critical power protection
- 5U rack/tower form factor fits standard server cabinets or standalone use
- 2-minute full-load runtime and 7-minute half-load runtime
- Hot-swappable and replaceable batteries for easy maintenance
- Pure sine wave output ensures compatibility with sensitive equipment
- 93% efficiency with ENERGY STAR 2.0 certification reduces operational costs
- Wide input voltage range (180 V AC - 280 V AC) for stable operation
- Multiple output voltages (110 V AC - 240 V AC) support diverse devices
- RS-232 and USB ports for remote management and monitoring
- 3-year warranty covering electronics and batteries
Specifications
| Specifications | |
|---|---|
| Manufacturer | Para Systems, Inc |
| Manufacturer Part Number | ED10KRT-3KTF |
| Brand Name | Minuteman |
| Product Line | Endeavor |
| Product Model | ED10KRT-3KTF |
| Product Name | Endeavor ED10KRT-3KTF 10000VA Rack/Tower UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | Hardwired |
| Protection Type | Surge |
| Phase | Single Phase |
| Application/Usage | IT,Telecommunication,Security,Business,Infrastructure,Server,Network,Industrial,Large Enterprise,Corporate,VoIP |
| Efficiency | 93% |
| Power Description | |
| Load Capacity (VA) | 10 kVA |
| Load Capacity (Watt) | 8.87 kW |
| Input Voltage | 120 V AC,230 V AC |
| Input Voltage Range | 180 V AC - 280 V AC |
| Output Voltage | 208 V AC,220 V AC,230 V AC,240 V AC,120 V AC,115 V AC,110 V AC |
| Input Frequency | 40 Hz,70 Hz |
| Output Frequency | 50 Hz,60 Hz |
| Waveform Type | Pure Sine Wave |
| Surge Energy Rating | 3140 J |
| Display & Graphics | |
| Display | LCD |
| Management | |
| Network Management | RS-232 |
| Interfaces/Ports | |
| Serial Port | Yes |
| USB | Yes |
| EPO Port | Yes |
| Battery Information | |
| Battery Characteristics | Hot-swappable |
| Backup/Run Time (Full Load) | 2 Minute |
| Backup/Run Time (Half Load) | 7 Minute |
| Replaceable Battery | Yes |
| Environmental Conditions | |
| Maximum Operating Temperature | 104°F (40°C) |
| Storage Temperature | 5°F (-15°C) - 131°F (55°C) |
| Maximum Operating Elevation | 15000 ft (4572000 mm) |
| Maximum Storage Elevation | 50000 ft (15240000 mm) |
| Operating Humidity | 0% - 95% |
| Storage Relative Humidity | 0% - 95% |
| Physical Characteristics | |
| Form Factor | Rack/Tower |
| Rack Height | 5U |
| Height | 11.95" (303.53 mm) |
| Width | 17.24" (437.90 mm) |
| Weight (Approximate) | 258.97 lb (117466.82 g) |
| Miscellaneous | |
| Package Contents | Endeavor ED10KRT-3KTF 10000VA Rack/Tower UPS Comm. Cables |
| Energy Star | Yes |
| Energy Efficiency Certification | ENERGY STAR 2.0 |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) 2 |
| Warranty | |
| Limited Warranty | 3 Year |
| Additional Warranty Information | 3 Years (Electronics and Batteries) |
User Manual
FAQ
What is the power capacity of this Minuteman UPS?
The Minuteman Endeavor ED10KRT-3KTF has a load capacity of 10 kVA (kilovolt-amperes) and 8.87 kW (kilowatts). This double conversion online UPS can support substantial IT, server, and network equipment loads, providing clean, uninterrupted power during outages or disturbances.
How long does the battery backup last at full load?
At full load, this UPS provides 2 minutes of backup runtime. This duration allows for orderly shutdown of connected equipment or transition to generator power in critical environments like data centers or telecommunications facilities.
Can this UPS be installed in a server rack?
Yes, the Endeavor ED10KRT-3KTF features a rack/tower form factor with a 5U rack height, making it compatible with standard 19-inch server cabinets. It can also be deployed as a standalone tower unit, offering flexibility for various infrastructure layouts.
What type of power output does this UPS provide?
This UPS delivers pure sine wave output, which is essential for sensitive electronic equipment like servers, network gear, and industrial controls. Pure sine wave power mimics utility-grade electricity, ensuring compatibility and preventing damage to devices that require clean power.
Are the batteries hot-swappable in this unit?
Yes, the batteries are hot-swappable, allowing for maintenance or replacement without shutting down the UPS or connected equipment. This feature is critical for 24/7 operations where uptime is paramount, as it enables battery servicing without interrupting power protection.
What management interfaces are available on this UPS?
The UPS includes RS-232 and USB ports for remote monitoring and management. These interfaces allow integration with network management systems, enabling administrators to track power status, configure settings, and receive alerts from a central console.
What power capacity is listed for this UPS?
The listed power specification is 10 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 120 V AC,230 V AC, which helps position the unit for the right load level and installation role.