Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Minuteman ED10KRT-6KTF2 Endeavor 10000VA Rack/Tower UPS - 10 kVA - 8. 73 kW - Pure Sine Wave - 5U - Hot-Swappable Battery
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This UPS employs advanced DSP design and high power factor (0.9pf) technology to maximize power delivery efficiency. The unit accepts 120V or 230V AC input with a wide 180-280V AC input range, automatically adapting to varying utility conditions. Output delivers multiple voltage options including 120V, 208V, 220V, 230V, and 240V AC configurations to match regional power standards.
The pure sine wave output ensures compatibility with power factor corrected (PFC) power supplies found in modern servers, storage arrays, and network switches. A 3140J surge energy rating provides robust protection against transient voltage spikes. The LCD interface offers real-time monitoring of power quality, load levels, battery status, and system events.
This section brings together practical product details such as Plug/Connector Type, Protection Type, Phase, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
The Endeavor ED10KRT-6KTF2 combines enterprise-grade power protection with practical management features for critical infrastructure applications. Automatic internal bypass and Independent Battery Bypass (IBB) ensure continuous operation during maintenance or fault conditions without disrupting connected equipment.
Advanced Battery Management
Hot-swappable batteries enable replacement without system shutdown, while smart fan control optimizes cooling based on load and temperature conditions. The cold start function allows operation from battery power when utility power is unavailable.
- Hot-swappable design
- Smart thermal management
- Cold start capability
Comprehensive Monitoring
Multi-function color LCD touchscreen provides intuitive access to system status, configuration settings, and event logs. RS-232 and USB communication ports enable integration with network management systems and power monitoring software.
- Color LCD touchscreen
- RS-232 serial interface
- USB connectivity
Deployment / Use Cases
This 10000VA UPS is engineered for medium to large-scale deployments where power quality and runtime are critical. The unit supports IT infrastructure, telecommunications systems, security installations, industrial controls, and VoIP platforms across corporate, enterprise, and data center environments.
The rack/tower dual configuration makes it suitable for both dedicated server rooms and office installations. At 5U rack height, it integrates efficiently with standard 19-inch server cabinets while conserving valuable rack space. The 347-pound weight and robust construction ensure stability in both rack-mounted and free-standing applications.
Server Room Protection
Provides clean power to server racks, storage arrays, and network switches with sufficient runtime for graceful shutdown or transfer to backup generators during extended outages.
Telecommunications Infrastructure
Protects VoIP systems, PBX equipment, and communication servers from power disturbances that can disrupt voice and data services across enterprise networks.
Physical Profile
The Endeavor ED10KRT-6KTF2 measures 15.36 inches in height (390.14 mm), 17.24 inches in width (437.90 mm), and occupies 5U of rack space. Weighing approximately 347 pounds (157,455 grams), the unit features a sturdy steel construction suitable for both rack-mount and tower deployments. The form factor accommodates standard 19-inch server racks with front-accessible controls and status indicators for convenient monitoring in dense equipment environments.
- Width
- 17.24" (437.90 mm)
- Height
- 5U
- Weight
- 347.13 lb (157455.52 g)
What's in the Box
The package includes the complete UPS system with all necessary components for immediate deployment in rack or tower configurations.
Highlights
- 10000VA/8.73kW double-conversion online UPS
- Pure sine wave output for PFC-compatible equipment
- 5U rack/tower form factor with dual installation options
- Hot-swappable batteries for maintenance without downtime
- 93% energy efficiency with ENERGY STAR 2.0 certification
- Wide input voltage range (180-280V AC)
- Multiple output voltage configurations
- Color LCD touchscreen with real-time monitoring
- RS-232 and USB communication interfaces
- 3-year warranty covering electronics and batteries
Specifications
| Specifications | |
|---|---|
| Manufacturer | Para Systems, Inc |
| Manufacturer Part Number | ED10KRT-6KTF2 |
| Brand Name | Minuteman |
| Product Line | Endeavor |
| Product Model | ED10KRT-6KTF2 |
| Product Name | Endeavor ED10KRT-6KTF2 10000VA Rack/Tower UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | Hardwired |
| Protection Type | Surge |
| Phase | Single Phase |
| Application/Usage | IT,Telecommunication,Security,Business,Infrastructure,Server,Network,Industrial,Large Enterprise,Corporate,VoIP |
| Efficiency | 93% |
| Power Description | |
| Load Capacity (VA) | 10 kVA |
| Load Capacity (Watt) | 8.73 kW |
| Input Voltage | 120 V AC,230 V AC |
| Input Voltage Range | 180 V AC - 280 V AC |
| Output Voltage | 208 V AC,220 V AC,230 V AC,240 V AC,120 V AC,115 V AC,110 V AC |
| Input Frequency | 40 Hz,70 Hz |
| Output Frequency | 50 Hz,60 Hz |
| Waveform Type | Pure Sine Wave |
| Surge Energy Rating | 3140 J |
| Display & Graphics | |
| Display | LCD |
| Management | |
| Network Management | RS-232 |
| Interfaces/Ports | |
| Serial Port | Yes |
| USB | Yes |
| EPO Port | Yes |
| Battery Information | |
| Battery Characteristics | Hot-swappable |
| Backup/Run Time (Full Load) | 2 Minute |
| Backup/Run Time (Half Load) | 7 Minute |
| Replaceable Battery | Yes |
| Environmental Conditions | |
| Maximum Operating Temperature | 104°F (40°C) |
| Storage Temperature | 5°F (-15°C) - 131°F (55°C) |
| Maximum Operating Elevation | 15000 ft (4572000 mm) |
| Maximum Storage Elevation | 50000 ft (15240000 mm) |
| Operating Humidity | 0% - 95% |
| Storage Relative Humidity | 0% - 95% |
| Physical Characteristics | |
| Form Factor | Rack/Tower |
| Rack Height | 5U |
| Height | 15.36" (390.14 mm) |
| Width | 17.24" (437.90 mm) |
| Weight (Approximate) | 347.13 lb (157455.52 g) |
| Miscellaneous | |
| Package Contents | Endeavor ED10KRT-6KTF2 10000VA Rack/Tower UPS Comm. Cables |
| Energy Star | Yes |
| Energy Efficiency Certification | ENERGY STAR 2.0 |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) 2 |
| Warranty | |
| Limited Warranty | 3 Year |
| Additional Warranty Information | 3 Years (Electronics and Batteries) |
User Manual
FAQ
What is the power capacity of this Minuteman UPS?
The Endeavor ED10KRT-6KTF2 delivers 10,000 volt-amps (10 kVA) with an actual wattage rating of 8.73 kilowatts. This capacity supports medium to large server installations, network equipment racks, or telecommunications systems requiring clean, regulated power with substantial runtime during utility interruptions.
How long does the battery last during a power outage?
At full 10 kVA load, the UPS provides approximately 2 minutes of runtime, allowing for graceful system shutdown or transfer to backup power sources. At half load (5 kVA), runtime extends to approximately 7 minutes. These figures represent typical performance with fresh batteries under specified operating conditions.
Can this UPS be installed in a server rack?
Yes, the unit is designed for both rack-mount and tower deployments. The 5U form factor fits standard 19-inch server cabinets, while the included hardware supports secure rack installation. The 347-pound weight and sturdy construction ensure stability in rack environments, with front-accessible controls for convenient monitoring in data center configurations.
What type of power output does this UPS provide?
This double-conversion online UPS delivers pure sine wave output, which is essential for compatibility with modern power factor corrected (PFC) power supplies found in servers, storage systems, and network equipment. The output can be configured for 120V, 208V, 220V, 230V, or 240V AC operation to match regional power standards and equipment requirements.
Are the batteries replaceable without shutting down connected equipment?
Yes, the Endeavor ED10KRT-6KTF2 features hot-swappable batteries that can be replaced while the UPS continues to provide power to connected equipment. This design eliminates downtime during battery maintenance or replacement cycles, ensuring continuous protection for critical infrastructure without service interruption.
What communication and management options are available?
The UPS includes both RS-232 serial and USB ports for integration with network management systems and power monitoring software. The multi-function color LCD touchscreen provides local access to system status, configuration settings, event logs, and real-time power quality metrics. These interfaces support remote monitoring, alerting, and historical reporting for comprehensive power management.
What power capacity is listed for this UPS?
The listed power specification is 10 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 120 V AC,230 V AC, which helps position the unit for the right load level and installation role.