Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Minuteman ED10KRT-8KTF2 Endeavor 10000VA Rack/Tower UPS - 8. 64kW Double Conversion Online - 5U - Pure Sine Wave
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
Built with true double-conversion online technology, the Endeavor ED10KRT-8KTF2 provides complete isolation from input power anomalies. The DSP design and high power factor (0.9pf) optimize performance, while automatic internal bypass and Independent Battery Bypass (IBB) enhance reliability during maintenance or fault conditions.
The multi-function color LCD touchscreen offers intuitive monitoring and control. Smart fan control adjusts cooling based on load and temperature, and the cold start function allows operation from battery power when AC input is unavailable. Communication options include USB and RS-232 ports for integration with network management systems.
This section brings together practical product details such as Plug/Connector Type, Protection Type, Phase, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
This UPS combines high power capacity with advanced protection features for demanding environments. The double conversion topology ensures clean, stable power output regardless of input conditions, protecting connected equipment from surges, sags, and frequency variations.
Reliable Runtime
Provides 2 minutes of backup at full load and 7 minutes at half load, with hot-swappable batteries for continuous operation during maintenance.
- Hot-swappable battery design
- Replaceable battery system
Advanced Management
Features a color LCD touchscreen for real-time monitoring and supports USB and RS-232 communication for remote management and integration.
- Multi-function color LCD
- USB and RS-232 ports
Robust Protection
Includes automatic internal bypass, Independent Battery Bypass, and pure sine wave output to safeguard sensitive equipment.
- Pure sine wave output
- Automatic internal bypass
Deployment / Use Cases
The Endeavor ED10KRT-8KTF2 is designed for environments requiring uninterrupted power for critical systems. Its 10000VA capacity and rack/tower flexibility make it ideal for data centers, server rooms, network closets, and industrial control systems.
In telecommunications installations, this UPS ensures continuous operation of VoIP systems and network equipment. For security applications, it provides backup power for surveillance systems and access control panels. The wide input voltage range (180-280V AC) and multiple output voltages support global deployment in corporate offices, large enterprises, and infrastructure projects.
This section brings together practical product details such as Plug/Connector Type, Protection Type, Phase, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Data Center Protection
Safeguards servers, storage arrays, and networking equipment with double conversion technology and hot-swappable batteries.
Industrial Applications
Supports control systems, PLCs, and industrial automation with pure sine wave output and robust environmental tolerances.
Physical Profile
The UPS measures 15.36" (390.14 mm) in height and 17.24" (437.90 mm) in width, with a 5U rack height for standard rack compatibility. Weighing approximately 380.19 lb (172451.28 g), the unit is constructed for durability in rack or tower configurations. The form factor supports flexible deployment in server racks or as a standalone tower, with mounting hardware included for rack installation.
- Width
- 17.24" (437.90 mm)
- Height
- 5U
- Weight
- 380.19 lb (172451.28 g)
What's in the Box
The package includes the Endeavor ED10KRT-8KTF2 10000VA Rack/Tower UPS and necessary communication cables for immediate deployment.
Package contents include Endeavor ED10KRT-8KTF2 10000VA Rack/Tower UPS Comm. Cables, Endeavor ED10KRT-8KTF2 10000VA Rack/Tower UPS. These included items support setup, installation, and immediate deployment without needing to source the core bundled accessories separately.
Highlights
- 10000VA / 8.64kW double conversion online UPS
- 5U rack/tower form factor with flexible deployment
- Pure sine wave output for sensitive equipment
- Hot-swappable batteries for maintenance without downtime
- Color LCD touchscreen for intuitive monitoring
- USB and RS-232 communication ports
- 93% efficiency with ENERGY STAR 2.0 certification
- Wide input voltage range: 180-280V AC
- Automatic internal bypass and IBB for reliability
- 3-year warranty covering electronics and batteries
Specifications
| Specifications | |
|---|---|
| Manufacturer | Para Systems, Inc |
| Manufacturer Part Number | ED10KRT-8KTF2 |
| Brand Name | Minuteman |
| Product Line | Endeavor |
| Product Model | ED10KRT-8KTF2 |
| Product Name | Endeavor ED10KRT-8KTF2 10000VA Rack/Tower UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | Hardwired |
| Protection Type | Surge |
| Phase | Single Phase |
| Application/Usage | IT,Telecommunication,Security,Business,Infrastructure,Server,Network,Industrial,Large Enterprise,Corporate,VoIP |
| Efficiency | 93% |
| Power Description | |
| Load Capacity (VA) | 10 kVA |
| Load Capacity (Watt) | 8.64 kW |
| Input Voltage | 120 V AC,230 V AC |
| Input Voltage Range | 180 V AC - 280 V AC |
| Output Voltage | 208 V AC,220 V AC,230 V AC,240 V AC,120 V AC,115 V AC,110 V AC |
| Input Frequency | 40 Hz,70 Hz |
| Output Frequency | 50 Hz,60 Hz |
| Waveform Type | Pure Sine Wave |
| Surge Energy Rating | 3140 J |
| Display & Graphics | |
| Display | LCD |
| Management | |
| Network Management | RS-232 |
| Interfaces/Ports | |
| Serial Port | Yes |
| USB | Yes |
| EPO Port | Yes |
| Battery Information | |
| Battery Characteristics | Hot-swappable |
| Backup/Run Time (Full Load) | 2 Minute |
| Backup/Run Time (Half Load) | 7 Minute |
| Replaceable Battery | Yes |
| Environmental Conditions | |
| Maximum Operating Temperature | 104°F (40°C) |
| Storage Temperature | 5°F (-15°C) - 131°F (55°C) |
| Maximum Operating Elevation | 15000 ft (4572000 mm) |
| Maximum Storage Elevation | 50000 ft (15240000 mm) |
| Operating Humidity | 0% - 95% |
| Storage Relative Humidity | 0% - 95% |
| Physical Characteristics | |
| Form Factor | Rack/Tower |
| Rack Height | 5U |
| Height | 15.36" (390.14 mm) |
| Width | 17.24" (437.90 mm) |
| Weight (Approximate) | 380.19 lb (172451.28 g) |
| Miscellaneous | |
| Package Contents | Endeavor ED10KRT-8KTF2 10000VA Rack/Tower UPS Comm. Cables |
| Energy Star | Yes |
| Energy Efficiency Certification | ENERGY STAR 2.0 |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) 2 |
| Warranty | |
| Limited Warranty | 3 Year |
| Additional Warranty Information | 3 Years (Electronics and Batteries) |
User Manual
FAQ
What is the power capacity of this UPS?
The Minuteman Endeavor ED10KRT-8KTF2 provides 10000VA (10 kVA) and 8.64kW of continuous power capacity. This double conversion online UPS delivers clean, stable power for critical IT and industrial equipment with 93% efficiency.
How long does the battery backup last?
At full load, the UPS provides 2 minutes of backup runtime. At half load, runtime extends to 7 minutes. The hot-swappable battery design allows for battery replacement without shutting down connected equipment.
What input and output voltages does this UPS support?
Input voltage accepts 120V AC and 230V AC, with a wide range of 180-280V AC. Output voltage provides multiple options: 208V AC, 220V AC, 230V AC, 240V AC, 120V AC, 115V AC, and 110V AC, making it suitable for various regional standards.
Can this UPS be rack-mounted?
Yes, the Endeavor ED10KRT-8KTF2 features a 5U rack/tower form factor. It can be installed in standard server racks using included mounting hardware or deployed as a standalone tower, offering flexibility for different environments.
What management options are available?
The UPS includes a multi-function color LCD touchscreen for local monitoring and control. For remote management, it offers USB and RS-232 communication ports, enabling integration with network management systems and monitoring software.
What warranty coverage is provided?
Minuteman provides a 3-year limited warranty covering both electronics and batteries. This comprehensive warranty ensures protection against defects in materials and workmanship for three years from the date of purchase.
What power capacity is listed for this UPS?
The listed power specification is 10 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 120 V AC,230 V AC, which helps position the unit for the right load level and installation role.