Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Minuteman ED10KTF Endeavor 10000VA/10kW Tower UPS - Double Conversion Online - AVR - 120/230V AC Input - 120/208/230/240V AC Output - 3 Min Full Load
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This double conversion online UPS continuously converts incoming AC power to DC and back to AC, providing complete isolation from utility power issues. The unit accepts a wide input voltage range of 110-300V AC and delivers stable output at 120, 208, 230, or 240V AC with pure sine wave quality essential for sensitive electronics.
The battery subsystem comprises 20 sealed, maintenance-free VRLA lead-acid batteries operating at 240V DC. Under full 10 kW load, the system provides 3 minutes of runtime, extending to 9 minutes at half load. A surge energy rating of 880 joules offers additional protection against transient voltage spikes.
This section brings together practical product details such as AVR, Plug/Connector Type, Receptacle Type, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
The Endeavor ED10KTF combines industrial-grade power protection with operational transparency and deployment flexibility. Its double conversion topology ensures zero transfer time during power transitions, while the wide input voltage range accommodates unstable utility power conditions common in industrial and commercial settings.
Reliable Battery System
Twenty maintenance-free VRLA batteries provide scalable runtime with sealed, non-spillable construction for safe installation in equipment rooms and data centers.
- Sealed/Non-spillable design
- Maintenance-free operation
- 240V DC system voltage
Comprehensive Monitoring
The LCD display delivers clear status indicators for AC input, battery condition, UPS faults, and system voltage, enabling proactive maintenance and rapid troubleshooting.
- LCD status display
- Real-time system monitoring
- Fault indication
Environmental Compliance
Manufactured to RoHS 2 standards with environmentally friendly materials, this UPS meets current regulatory requirements for hazardous substance restriction.
- RoHS 2 compliant
- Environmentally friendly
- 104°F operating maximum
Deployment / Use Cases
The ED10KTF's 10 kVA capacity and tower form factor make it ideal for protecting consolidated server racks, network distribution frames, and critical infrastructure in small to medium data centers. Its hardwired connections support permanent installation where plug-and-receptacle configurations would be insufficient for current demands.
This UPS effectively secures telecommunications equipment including VoIP phone systems, distributed antenna systems (DAS), and cellular infrastructure where power continuity directly impacts service availability. Educational institutions, security operations centers, and industrial control systems benefit from the unit's pure sine wave output and voltage regulation for sensitive monitoring and control electronics.
Data Center & Network Protection
Provides backup power for server racks, network switches, and storage systems in equipment closets and small data centers, maintaining operations during utility outages.
Telecommunications Infrastructure
Secures VoIP systems, DAS nodes, and cellular equipment with clean power delivery and sufficient runtime for graceful shutdown or generator transition.
Physical Profile
The tower-form-factor UPS measures 32.5" (825.5 mm) in height and 9.8" (248.92 mm) in width, with an approximate weight of 124.51 kg (274.5 lb). This substantial footprint accommodates the 20-battery array and power electronics while providing stability for floor-mounted deployment. The unit operates in environments up to 104°F (40°C), suitable for most equipment rooms without specialized cooling.
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 32.50" (825.50 mm), 9.80" (248.92 mm), 124.51 kg. This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 9.80" (248.92 mm)
- Height
- 32.50" (825.50 mm)
- Weight
- 124.51 kg
Highlights
- 10000VA/10kW double conversion online UPS with pure sine wave output
- Automatic voltage regulation (AVR) for brownout and overvoltage protection
- Wide input voltage range: 110-300V AC for unstable power conditions
- Multiple output voltages: 120, 208, 230, or 240V AC output selection
- 3-minute runtime at full load, 9-minute runtime at half load
- 20 sealed maintenance-free VRLA lead-acid batteries at 240V DC
- Hardwired terminal block connections for high-current applications
- LCD display with status indicators for AC input, battery, and faults
- RoHS 2 compliant construction with 3-year limited warranty
- Tower form factor for floor-mounted deployment in equipment rooms
Specifications
| Specifications | |
|---|---|
| Manufacturer | Para Systems, Inc |
| Manufacturer Part Number | ED10KTF |
| Brand Name | Minuteman |
| Product Line | Endeavor |
| Product Model | ED10KTF |
| Product Name | Endeavor ED10KTF 10000VA Tower UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| AVR | Yes |
| Plug/Connector Type | Hardwire Terminal Block |
| Receptacle Type | Hardwire Terminal Block |
| Phase | Single Phase |
| Application/Usage | Network,Data Center,Network Closet,Security System,Education,Telephone,VoIP Phone System,Distributed Antenna System (DAS),Cellular System |
| Power Description | |
| Load Capacity (VA) | 10 kVA |
| Load Capacity (Watt) | 10 kW |
| Input Voltage | 120 V AC,230 V AC |
| Input Voltage Range | 110 V AC - 300 V AC |
| Output Voltage | 120 V AC,208 V AC,230 V AC,240 V AC |
| Input Frequency | 60 Hz |
| Output Frequency | 60 Hz |
| Waveform Type | Pure Sine Wave |
| Surge Energy Rating | 880 J |
| Display & Graphics | |
| Display | LCD |
| Controls/Indicators | |
| Status Indicators | LCD Display Status: AC Input Battery UPS Fault |
| Battery Information | |
| DC System Voltage | 240 V DC |
| Number of Batteries | 20 |
| Battery Characteristics | Sealed/Non-spillable/Maintenance-free/VRLA |
| Battery Chemistry | Lead Acid |
| Backup/Run Time (Full Load) | 3 Minute |
| Backup/Run Time (Half Load) | 9 Minute |
| Environmental Conditions | |
| Maximum Operating Temperature | 104°F (40°C) |
| Physical Characteristics | |
| Form Factor | Tower |
| Height | 32.50" (825.50 mm) |
| Width | 9.80" (248.92 mm) |
| Weight (Approximate) | 124.51 kg |
| Miscellaneous | |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) 2 |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the power capacity of the Minuteman ED10KTF UPS?
The Minuteman ED10KTF provides 10 kVA (10,000 VA) and 10 kW of power capacity. This double conversion online UPS can support substantial loads including server racks, network equipment, and telecommunications systems with pure sine wave output quality.
What runtime can I expect from this UPS at full and half load?
At full 10 kW load, the ED10KTF provides 3 minutes of battery runtime. When supporting a 5 kW half load, runtime extends to 9 minutes. These runtimes come from the unit's 20 sealed VRLA lead-acid batteries operating at 240V DC.
What input and output voltages does this UPS support?
The UPS accepts input voltages of 120V AC or 230V AC within a range of 110-300V AC. It delivers output at 120V AC, 208V AC, 230V AC, or 240V AC, providing flexibility for different equipment voltage requirements in North American and international deployments.
Is this a tower or rack-mount UPS unit?
The ED10KTF features a tower form factor designed for floor-mounted installation. With dimensions of 32.5" height and 9.8" width, and a weight of approximately 124.51 kg, it provides a stable footprint for equipment room deployment without requiring rack mounting hardware.
What type of batteries does this UPS use, and are they maintenance-free?
The system uses 20 sealed, non-spillable, maintenance-free VRLA (Valve Regulated Lead Acid) batteries with lead-acid chemistry. These batteries require no watering or regular maintenance, making them suitable for unattended operation in equipment rooms and data centers.
What applications is this UPS designed to protect?
The ED10KTF is engineered for network equipment, data centers, security systems, educational infrastructure, telephone/VoIP systems, distributed antenna systems (DAS), and cellular systems. Its 10 kVA capacity and hardwired connections suit it for protecting consolidated critical loads in commercial and industrial environments.
What power capacity is listed for this UPS?
The listed power specification is 10 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 120 V AC,230 V AC, which helps position the unit for the right load level and installation role.