Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Minuteman ED5000RTXLMB Endeavor 4556VA Rack/Tower UPS - 4U Double Conversion Online - 208V AC Input - 6. 3 Min Full Load Runtime
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This UPS employs true double conversion technology that continuously converts AC input to DC and back to clean AC output, providing complete power conditioning and isolation. The 4.56 kVA capacity supports substantial equipment loads while maintaining efficiency through advanced power electronics.
Runtime performance delivers 6.3 minutes at full load and extends to 12.3 minutes at half load, providing adequate time for graceful shutdowns or generator transfer. The unit accepts 208V AC input at 70 Hz and outputs regulated power at 60 Hz with voltage options of 208V, 212V, or 120V AC to accommodate various equipment requirements.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
The Endeavor ED5000RTXLMB combines robust power protection with deployment flexibility and management capabilities essential for modern IT infrastructure. SNMP management enables remote monitoring and control, while the serial port provides local management options for environments without network connectivity.
True Double Conversion Protection
Complete isolation from input power issues with continuous AC-DC-AC conversion ensures clean, regulated output regardless of utility power quality fluctuations or disturbances.
Flexible Deployment Options
Configure as either a rack-mounted 4U unit or standalone tower with included foot brackets and rail kit, adapting to diverse data center and server room layouts.
Comprehensive Outlet Configuration
Eight NEMA receptacles include one L6-30R, one L6-20R, and six 5-15/20R outlets to support mixed equipment types from servers to networking gear.
Deployment / Use Cases
This UPS serves environments where power quality and uptime are critical, including data centers, server rooms, telecommunications facilities, and industrial control systems. The 208V input configuration makes it particularly suitable for three-phase power distribution systems common in commercial and industrial settings.
The rack/tower flexibility allows installation in standard 19-inch racks or as a standalone unit where rack space is limited. The included maintenance bypass switch enables servicing without disrupting connected equipment, while the isolation step-down transformer provides additional protection for sensitive electronics.
Server Room Power Protection
Ideal for protecting rack-mounted servers, storage arrays, and network switches in data centers and server rooms where 208V power distribution is standard.
Telecommunications Infrastructure
Suitable for VoIP systems, PBX equipment, and telecom racks requiring clean power with multiple voltage outputs and extended runtime for critical communications.
Physical Profile
The 4U rack-mountable design occupies minimal vertical space while providing substantial power capacity. With dimensions of 10.50 inches high, 17.30 inches wide, and 26.20 inches deep, the unit fits standard 19-inch racks while allowing adequate airflow for cooling. The rack/tower convertible design includes both mounting rails for rack installation and foot brackets for tower deployment, offering installation flexibility for various environments.
- Width
- 17.30" (439.42 mm)
- Depth
- 26.20" (665.48 mm)
- Height
- 4U
What's in the Box
The complete package includes all necessary components for immediate deployment and operation.
Highlights
- 4556VA double conversion online UPS with true isolation
- 4U rack/tower convertible form factor with included mounting hardware
- 6.3-minute runtime at full load, 12.3 minutes at half load
- 208V AC input with 208V, 212V, and 120V AC output options
- SNMP manageable with serial port for remote monitoring
- Eight NEMA receptacles: 1×L6-30R, 1×L6-20R, 6×5-15/20R
- Includes maintenance bypass switch and isolation transformer
- Energy Star certified and RoHS 2 compliant
- 3-year limited warranty for peace of mind
Specifications
| Specifications | |
|---|---|
| Manufacturer | Para Systems, Inc |
| Manufacturer Part Number | ED5000RTXLMB |
| Brand Name | Minuteman |
| Product Line | Endeavor |
| Product Model | ED5000RTXLMB |
| Product Name | Endeavor ED5000RTXLMB 4556VA Rack/Tower UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | NEMA L6-30P |
| Receptacle Type | NEMA L6-30R,NEMA L6-20R,NEMA 5-15/20R |
| Receptacle Detail | 1 x NEMA L6-30R,1 x NEMA L6-20R,6 x NEMA 5-15/20R |
| Overload Protection | Yes |
| Power Description | |
| Load Capacity (VA) | 4.56 kVA |
| Input Voltage | 208 V AC |
| Output Voltage | 208 V AC,212 V AC,120 V AC |
| Input Frequency | 70 Hz |
| Output Frequency | 60 Hz |
| Management | |
| Network Management | SNMP Manageable |
| Interfaces/Ports | |
| Serial Port | Yes |
| Battery Information | |
| Backup/Run Time (Full Load) | 6.30 Minute |
| Backup/Run Time (Half Load) | 12.30 Minute |
| Physical Characteristics | |
| Form Factor | Rack/Tower |
| Rack Height | 4U |
| Height | 10.50" (266.70 mm) |
| Width | 17.30" (439.42 mm) |
| Depth | 26.20" (665.48 mm) |
| Miscellaneous | |
| Package Contents | Endeavor ED5000RTXLMB 4556VA Rack/Tower UPS Rail Kit Foot Brackets 1 x Battery Pack Maintenance Bypass Switch Isolation Stepdown Transformer |
| Software Included | SentryHD |
| Energy Star | Yes |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) 2 |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the power capacity of this Minuteman UPS?
The Minuteman Endeavor ED5000RTXLMB provides 4.56 kVA (kilovolt-ampere) load capacity. This substantial power rating supports critical IT equipment including servers, network switches, and storage systems in commercial and data center environments.
How long will this UPS run on battery power?
Runtime varies by load. At full 4.56 kVA load, the UPS provides 6.3 minutes of battery backup. At half load (2.28 kVA), runtime extends to 12.3 minutes. This provides adequate time for graceful shutdowns or transfer to generator power during utility outages.
What input voltage does this UPS require?
This UPS is designed for 208V AC input environments, making it suitable for three-phase power distribution systems common in commercial buildings and data centers. The input frequency is 70 Hz, and the unit converts this to a stable 60 Hz output.
Can this UPS be installed in a standard server rack?
Yes, the Endeavor ED5000RTXLMB is a 4U rack-mountable unit that fits standard 19-inch server racks. The package includes a complete rail kit for rack installation. Alternatively, it can be deployed as a standalone tower using the included foot brackets.
What types of outlets does this UPS provide?
The UPS features eight NEMA receptacles: one L6-30R, one L6-20R, and six 5-15/20R outlets. This mixed configuration supports various equipment types from servers and switches to networking gear and peripheral devices in a single power protection solution.
How can I monitor and manage this UPS remotely?
The UPS supports SNMP (Simple Network Management Protocol) management for remote monitoring and control over your network. It also includes a serial port for local management. The included SentryHD software provides additional monitoring and alerting capabilities for comprehensive power management.
What power capacity is listed for this UPS?
The listed power specification is 4.56 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 208 V AC, which helps position the unit for the right load level and installation role.