Minuteman ED5200RTXL Endeavor 5000VA Rack/Tower UPS - 4U Double Conversion Online - 208V AC Input/Output - 5. 8 Minute Full Load Runtime
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This UPS employs double conversion online technology that continuously converts AC input to DC and back to clean AC output, providing complete isolation from power line disturbances. The unit accepts 208V AC input at 70 Hz and delivers stable 208V or 212V AC output at 60 Hz, with automatic voltage regulation maintaining consistent power quality.
The ED5200RTXL features comprehensive protection with overload protection, serial connectivity for local management, and SNMP capability for network integration. Its power conditioning eliminates sags, surges, spikes, and electrical noise while maintaining sine wave output throughout the backup cycle.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Overload Protection, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Frequency Conversion
Converts 70 Hz input to stable 60 Hz output, ensuring compatibility with North American equipment standards.
Key Product Advantages
The Endeavor ED5200RTXL combines industrial-grade power protection with flexible deployment options for modern data center and server room applications.
For buyers comparing similar models, the strongest advantage is usually the balance between dependable day-to-day operation and a simpler rollout experience. That means less time spent troubleshooting fit, compatibility, or user adoption after installation, which is especially important for shared business environments and repeat purchasing decisions.
Advantages are also easier to justify when they translate into measurable operational value, such as less downtime, more consistent user experience, easier replacement planning, or better alignment with existing accessories and workflows. That practical value tends to matter more than broad marketing language when teams are standardizing purchases.
Deployment / Use Cases
The ED5200RTXL is engineered for environments requiring robust power protection with flexible installation options. Its 4U rack-mount profile fits standard server cabinets while the tower configuration supports standalone deployment where rack space is limited.
This UPS excels in protecting critical loads in small to medium server rooms, network operation centers, and telecommunications installations. The 208V AC compatibility makes it ideal for commercial buildings with three-phase power distribution, while the hardwired connection option supports permanent installation scenarios.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Overload Protection, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Server Room Protection
Safeguards rack-mounted servers, switches, and storage arrays with clean power during outages and disturbances.
Network Infrastructure
Provides backup power for core networking equipment, ensuring continuous connectivity during power events.
Physical Profile
The ED5200RTXL occupies 4U of rack space with dimensions of 7 inches high, 17.30 inches wide, and 26 inches deep. This compact footprint maximizes power density in standard 19-inch server racks while maintaining adequate ventilation for reliable operation. The unit includes both rack-mount rails and foot brackets, allowing quick conversion between rack and tower configurations based on deployment requirements.
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 4U, 17.30" (439.42 mm), 26" (660.40 mm). This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 17.30" (439.42 mm)
- Depth
- 26" (660.40 mm)
- Height
- 4U
What's in the Box
The package includes all necessary components for immediate deployment in either rack or tower configuration.
Package contents include Endeavor ED5200RTXL 5000VA Rack/Tower UPS Rail Kit Foot Brackets, 1 x Battery Pack, SentryHD, Endeavor ED5200RTXL 5000VA Rack/Tower UPS. These included items support setup, installation, and immediate deployment without needing to source the core bundled accessories separately.
Highlights
- 5000VA/5 kVA double conversion online UPS
- Rack/tower convertible 4U form factor
- 5.8-minute runtime at full load (11.3 minutes at half load)
- 208V AC input with 208V/212V AC output
- SNMP manageable for network integration
- Includes SentryHD management software
- Energy Star certified for energy efficiency
- 3-year limited warranty
- RoHS 2 environmental compliance
- Hardwired receptacle with NEMA L6-30P plug
Specifications
| Specifications | |
|---|---|
| Manufacturer | Para Systems, Inc |
| Manufacturer Part Number | ED5200RTXL |
| Brand Name | Minuteman |
| Product Line | Endeavor |
| Product Model | ED5200RTXL |
| Product Name | Endeavor ED5200RTXL 5000VA Rack/Tower UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | NEMA L6-30P |
| Receptacle Type | Hardwired |
| Overload Protection | Yes |
| Power Description | |
| Load Capacity (VA) | 5 kVA |
| Input Voltage | 208 V AC |
| Output Voltage | 208 V AC,212 V AC |
| Input Frequency | 70 Hz |
| Output Frequency | 60 Hz |
| Management | |
| Network Management | SNMP Manageable |
| Interfaces/Ports | |
| Serial Port | Yes |
| Battery Information | |
| Backup/Run Time (Full Load) | 5.80 Minute |
| Backup/Run Time (Half Load) | 11.30 Minute |
| Physical Characteristics | |
| Form Factor | Rack/Tower |
| Rack Height | 4U |
| Height | 7" (177.80 mm) |
| Width | 17.30" (439.42 mm) |
| Depth | 26" (660.40 mm) |
| Miscellaneous | |
| Package Contents | Endeavor ED5200RTXL 5000VA Rack/Tower UPS Rail Kit Foot Brackets 1 x Battery Pack |
| Software Included | SentryHD |
| Energy Star | Yes |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) 2 |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the power capacity of this UPS?
The Minuteman Endeavor ED5200RTXL provides 5000VA (5 kVA) of power capacity. This double conversion online UPS can support substantial server and networking loads, making it suitable for small to medium server rooms and network infrastructure applications.
How long does the battery backup last during a power outage?
At full 5 kVA load, the UPS provides 5.8 minutes of runtime. When operating at half load (2.5 kVA), the runtime extends to 11.3 minutes. This provides adequate time for graceful system shutdown or transfer to generator power in commercial environments.
Can this UPS be installed in both rack and tower configurations?
Yes, the ED5200RTXL is designed for both rack and tower deployment. The package includes a rail kit for 4U rack mounting in standard 19-inch server cabinets, plus foot brackets for standalone tower installation. This flexibility allows deployment in various data center and server room layouts.
What input and output voltages does this UPS support?
The UPS accepts 208V AC input and provides 208V or 212V AC output. This voltage range is common in North American commercial three-phase power systems, making the unit compatible with standard server and networking equipment in business environments.
How can I monitor and manage this UPS remotely?
The ED5200RTXL includes SNMP management capability for network integration, allowing remote monitoring and control via standard network management systems. The package also includes SentryHD software for local management and configuration, providing comprehensive oversight of UPS status and performance.
What type of power protection technology does this UPS use?
This unit employs double conversion online technology, which continuously converts incoming AC power to DC and then back to clean AC output. This provides complete isolation from power line disturbances including sags, surges, spikes, and electrical noise, ensuring consistent power quality to connected equipment.
What power capacity is listed for this UPS?
The listed power specification is 5 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 208 V AC, which helps position the unit for the right load level and installation role.