Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Minuteman ED5KRT-3KTF Endeavor 5000VA/4. 37kW Rack/Tower UPS - 4U Double Conversion Online - 2 Min Full Load Runtime - Hardwired 120/230V AC Input
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
Built on double conversion online topology, the Endeavor ED5KRT-3KTF continuously conditions incoming power, eliminating voltage spikes, sags, and frequency variations before they reach connected equipment. The true sine wave output ensures compatibility with power supplies in servers, networking gear, and telecommunications systems.
The unit features 3140 joules of surge suppression and an integrated circuit breaker for overload protection. Input frequency ranges from 40-70Hz with output stabilized at 50/60Hz, supporting international power standards. Cold start functionality allows battery-powered operation without utility input when needed.
This section brings together practical product details such as Plug/Connector Type, Phase, Efficiency Detail, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The Endeavor ED5KRT-3KTF combines high power capacity with deployment flexibility, making it suitable for data centers, server rooms, and industrial applications where reliable backup power is non-negotiable.
Hot-Swappable Battery Design
Replace batteries without shutting down connected equipment, maintaining continuous uptime during maintenance procedures.
- Field-replaceable battery modules
- No service interruption during replacement
- Simplifies battery refresh cycles
Comprehensive Management Options
Multiple interface options provide flexibility for monitoring and control in diverse IT environments.
- RS-232 for legacy systems
- USB for modern management software
- EPO port for emergency shutdown
Robust Environmental Tolerance
Operates reliably across wide temperature and humidity ranges for deployment in challenging conditions.
- 0-104°F operating temperature
- 0-95% operating humidity
- 15,000 ft maximum operating elevation
Deployment / Use Cases
The 5000VA capacity and rack/tower form factor make this UPS ideal for protecting medium-density server racks, network closets, and telecommunications infrastructure. The hardwired installation suits permanent deployments where outlet-based connections are impractical or insufficient.
With applications spanning IT, telecommunications, security systems, VoIP infrastructure, and industrial controls, the Endeavor ED5KRT-3KTF provides the power conditioning and runtime needed to prevent data loss and equipment damage during utility disturbances.
This section brings together practical product details such as Plug/Connector Type, Phase, Efficiency Detail, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Server Room Protection
Safeguard critical servers and storage arrays with sufficient runtime for graceful shutdowns or continued operation during brief outages.
Network Infrastructure Support
Maintain connectivity for switches, routers, and security appliances through power events that would otherwise disrupt network operations.
Physical Profile
The 4U rack-mountable design measures 10.22"H × 17.24"W × 23.82"D (259.59 × 437.90 × 605.03 mm), fitting standard 19-inch server racks while providing substantial power capacity in a compact footprint. At 210.48 pounds, the unit requires proper rack mounting hardware and consideration of weight distribution in multi-U installations. The rack/tower flexibility allows freestanding deployment where rack space is unavailable.
- Width
- 17.24" (437.90 mm)
- Height
- 10.22" (259.59 mm)
- Weight
- 210.48 lb (95472.12 g)
- Length
- 23.82" (605.03 mm)
What's in the Box
The package includes the complete UPS unit with all necessary communication cables for immediate deployment.
Package contents include Endeavor ED5KRT-3KTF 5000VA Rack/Tower UPS Comm. Cables, Endeavor ED5KRT-3KTF 5000VA Rack/Tower UPS. These included items support setup, installation, and immediate deployment without needing to source the core bundled accessories separately.
Highlights
- 5000VA/4.37kW double conversion online UPS with true sine wave output
- 4U rack/tower form factor for flexible deployment in server rooms and data centers
- 2-minute runtime at full load, 7 minutes at half load for critical equipment protection
- Hardwired 120V/230V AC input with 0-300V AC input voltage range
- Hot-swappable, field-replaceable batteries for maintenance without downtime
- 93% efficiency in AC mode with ENERGY STAR 2.0 certification
- RS-232, USB, and EPO ports for comprehensive management and control
- Wide operating temperature range (32-104°F) and humidity tolerance (0-95%)
- 3140 joules surge suppression with integrated circuit breaker protection
- 3-year limited warranty covering electronics and batteries
Specifications
| Specifications | |
|---|---|
| Manufacturer | Para Systems, Inc |
| Manufacturer Part Number | ED5KRT-3KTF |
| Brand Name | Minuteman |
| Product Line | Endeavor |
| Product Model | ED5KRT-3KTF |
| Product Name | Endeavor ED5KRT-3KTF 5000VA Rack/Tower UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | Hardwired |
| Phase | Single Phase |
| Efficiency Detail | 93% (AC Mode) |
| Application/Usage | IT,Telecommunication,Security,Business,Infrastructure,Server,Network,Industrial,Enterprise Installation,Corporate,VoIP |
| Surge Suppression | Yes |
| Features | Cold Start Function |
| Power Description | |
| Load Capacity (VA) | 5 kVA |
| Load Capacity (Watt) | 4.37 kW |
| Input Voltage | 120 V AC,230 V AC |
| Input Voltage Range | 0 V AC - 300 V AC,156 V AC - 280 V AC |
| Input Current | 32 A |
| Output Voltage | 208 V AC,220 V AC,230 V AC,240 V AC,110 V AC,115 V AC,120 V AC |
| Input Frequency | 40 Hz,70 Hz |
| Output Frequency | 50 Hz,60 Hz |
| Waveform Type | True Sine Wave |
| Surge Energy Rating | 3140 J |
| Circuit Breaker | Yes |
| Display & Graphics | |
| Display | LCD |
| Management | |
| Network Management | RS-232 |
| Interfaces/Ports | |
| Serial Port | Yes |
| USB | Yes |
| EPO Port | Yes |
| Battery Information | |
| Backup/Run Time (Full Load) | 2 Minute |
| Backup/Run Time (Half Load) | 7 Minute |
| Hot Swappable | Yes |
| Replaceable Battery | Yes |
| Environmental Conditions | |
| Maximum Operating Elevation | 15000 ft (4572000 mm) |
| Maximum Storage Elevation | 50000 ft (15240000 mm) |
| Storage Temperature | 5°F (-15°C) - 131°F (55°C) |
| Operating Humidity | 0% - 95% |
| Storage Relative Humidity | 0% - 95% |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Operating Temperature | 104°F (40°C) |
| Physical Characteristics | |
| Height | 10.22" (259.59 mm) |
| Width | 17.24" (437.90 mm) |
| Length | 23.82" (605.03 mm) |
| Rack Height | 4U |
| Form Factor | Rack/Tower |
| Weight (Approximate) | 210.48 lb (95472.12 g) |
| Miscellaneous | |
| Package Contents | Endeavor ED5KRT-3KTF 5000VA Rack/Tower UPS Comm. Cables |
| Energy Star | Yes |
| Energy Efficiency Certification | ENERGY STAR 2.0 |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) 2 |
| Warranty | |
| Limited Warranty | 3 Year |
| Additional Warranty Information | 3 Years (Electronics and Batteries) |
FAQ
What is the power capacity of this Minuteman UPS?
The Endeavor ED5KRT-3KTF provides 5000VA (5 kVA) apparent power and 4370W (4.37 kW) real power capacity. This substantial capacity supports medium-density server racks, network equipment, and telecommunications systems requiring reliable backup power during utility interruptions.
How long will this UPS run at full load during a power outage?
At full connected load, the UPS provides approximately 2 minutes of runtime from its internal batteries. At half load (2185W), runtime extends to approximately 7 minutes. These runtimes allow for graceful shutdowns of connected equipment or continued operation through brief utility disturbances.
What input voltages does this UPS support?
The hardwired UPS accepts 120V AC or 230V AC single-phase input power. The input voltage range extends from 0-300V AC, with the normal operating range between 156-280V AC for 230V input configurations. This flexibility supports deployment in regions with different utility voltage standards.
Can this UPS be mounted in a standard server rack?
Yes, the Endeavor ED5KRT-3KTF occupies 4U (7 inches) of vertical space in a standard 19-inch server rack. The dimensions are 10.22"H × 17.24"W × 23.82"D. The unit also functions as a tower UPS for freestanding deployment where rack mounting isn't available.
What management interfaces are available on this UPS?
Management options include RS-232 serial connectivity for legacy monitoring systems, USB for modern management software integration, and an EPO (Emergency Power Off) port for safety shutdowns. The front-panel LCD display provides real-time status information including load percentage, input/output voltage, and battery status.
Are the batteries hot-swappable in this UPS model?
Yes, the Endeavor ED5KRT-3KTF features hot-swappable, field-replaceable battery modules. This design allows battery replacement without shutting down connected equipment, maintaining continuous uptime during maintenance procedures. The 3-year warranty covers both electronics and batteries.
What power capacity is listed for this UPS?
The listed power specification is 5 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 120 V AC,230 V AC, which helps position the unit for the right load level and installation role.