Minuteman ED5KRT-5KTF Endeavor 5000VA Rack/Tower UPS - 4U Double Conversion Online - 4. 28 kW - 2 Minute Full Load Runtime
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This double conversion online UPS maintains continuous power conditioning through its true sine wave output, compatible with 50/60 Hz systems. The unit accepts 120 V AC or 230 V AC input with a wide voltage range of 0-300 V AC, delivering stable output across 110-240 V AC for global compatibility.
Advanced protection features include 3140 J surge suppression, a built-in circuit breaker, and cold start capability for emergency power-up without utility input. The LCD provides real-time status monitoring, while RS-232, USB, and EPO ports enable comprehensive management and emergency shutdown integration.
This section brings together practical product details such as Plug/Connector Type, Phase, Efficiency Detail, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The Endeavor ED5KRT-5KTF combines robust power protection with practical deployment flexibility. Its double conversion topology ensures complete isolation from utility power anomalies, while the comprehensive connectivity suite supports integration with existing management systems.
High-Efficiency Operation
With 93% efficiency in AC mode and ENERGY STAR 2.0 certification, this UPS minimizes energy waste and reduces operational costs while maintaining premium power protection.
Flexible Deployment Options
The rack/tower design supports both 4U rack installation and standalone tower placement, adapting to diverse data center, server room, and network closet environments.
Maintenance-Friendly Design
Hot-swappable batteries allow replacement without system downtime, while the replaceable battery design extends service life and simplifies maintenance procedures.
Deployment / Use Cases
This UPS serves diverse applications from IT server protection to industrial control systems. The 2-minute runtime at full load provides critical window for graceful shutdowns, while the 7-minute half-load runtime supports extended operation for less demanding loads.
Compatible with IT, telecommunications, security, business infrastructure, server, network, industrial, enterprise installation, corporate, and VoIP applications, the unit adapts to multiple deployment scenarios while maintaining strict power quality standards.
Server Room Protection
Ideal for protecting critical servers, storage arrays, and network infrastructure in enterprise data centers, providing sufficient runtime for orderly shutdowns during extended outages.
Telecommunications Infrastructure
Supports VoIP systems, security installations, and communication equipment with clean sine wave power that prevents data corruption and equipment damage.
Industrial & Corporate Applications
Suitable for manufacturing environments, corporate offices, and facilities requiring reliable backup power for operational continuity and data preservation.
Physical Profile
The 4U rack-mountable design measures 10.22" (259.59 mm) in height, 17.24" (437.90 mm) in width, and 23.82" (605.03 mm) in depth, fitting standard server racks while providing substantial power capacity. At 243.54 lb (110467.89 g), the unit requires proper rack mounting hardware and consideration for floor loading in deployment planning.
The rack/tower form factor includes appropriate mounting hardware for secure installation, while the substantial weight ensures stability in both rack-mounted and standalone configurations. The design accommodates standard data center airflow patterns and accessibility for maintenance procedures.
- Width
- 17.24" (437.90 mm)
- Height
- 10.22" (259.59 mm)
- Weight
- 243.54 lb (110467.89 g)
- Length
- 23.82" (605.03 mm)
What's in the Box
The package includes the complete UPS system with all necessary components for immediate deployment.
Package contents include Endeavor ED5KRT-5KTF 5000VA Rack/Tower UPS Comm. Cables, Endeavor ED5KRT-5KTF 5000VA Rack/Tower UPS. These included items support setup, installation, and immediate deployment without needing to source the core bundled accessories separately.
Highlights
- 5000VA/4.28 kW double conversion online UPS with true sine wave output
- 2-minute runtime at full load, 7-minute runtime at half load for critical shutdown procedures
- Rack/tower design with 4U rack height for flexible deployment in server rooms and data centers
- Hot-swappable and replaceable batteries for maintenance without system downtime
- 93% efficiency in AC mode with ENERGY STAR 2.0 certification for reduced operational costs
- LCD display with RS-232, USB, and EPO ports for comprehensive monitoring and management
- Wide input voltage range (0-300 V AC) and multiple output voltages (110-240 V AC) for global compatibility
- 3140 J surge suppression with circuit breaker protection for connected equipment
- RoHS 2 compliant with 3-year warranty covering electronics and batteries
- Cold start function enables operation without utility power for emergency scenarios
Specifications
| Specifications | |
|---|---|
| Manufacturer | Para Systems, Inc |
| Manufacturer Part Number | ED5KRT-5KTF |
| Brand Name | Minuteman |
| Product Line | Endeavor |
| Product Model | ED5KRT-5KTF |
| Product Name | Endeavor ED5KRT-5KTF 5000VA Rack/Tower UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | Hardwired |
| Phase | Single Phase |
| Efficiency Detail | 93% (AC Mode) |
| Application/Usage | IT,Telecommunication,Security,Business,Infrastructure,Server,Network,Industrial,Enterprise Installation,Corporate,VoIP |
| Surge Suppression | Yes |
| Features | Cold Start Function |
| Power Description | |
| Load Capacity (VA) | 5 kVA |
| Load Capacity (Watt) | 4.28 kW |
| Input Voltage | 120 V AC,230 V AC |
| Input Voltage Range | 0 V AC - 300 V AC,156 V AC - 280 V AC |
| Input Current | 32 A |
| Output Voltage | 208 V AC,220 V AC,230 V AC,240 V AC,110 V AC,115 V AC,120 V AC |
| Input Frequency | 40 Hz,70 Hz |
| Output Frequency | 50 Hz,60 Hz |
| Waveform Type | True Sine Wave |
| Surge Energy Rating | 3140 J |
| Circuit Breaker | Yes |
| Display & Graphics | |
| Display | LCD |
| Management | |
| Network Management | RS-232 |
| Interfaces/Ports | |
| Serial Port | Yes |
| USB | Yes |
| EPO Port | Yes |
| Battery Information | |
| Backup/Run Time (Full Load) | 2 Minute |
| Backup/Run Time (Half Load) | 7 Minute |
| Hot Swappable | Yes |
| Replaceable Battery | Yes |
| Environmental Conditions | |
| Maximum Operating Elevation | 15000 ft (4572000 mm) |
| Maximum Storage Elevation | 50000 ft (15240000 mm) |
| Storage Temperature | 5°F (-15°C) - 131°F (55°C) |
| Operating Humidity | 0% - 95% |
| Storage Relative Humidity | 0% - 95% |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Operating Temperature | 104°F (40°C) |
| Physical Characteristics | |
| Height | 10.22" (259.59 mm) |
| Width | 17.24" (437.90 mm) |
| Length | 23.82" (605.03 mm) |
| Rack Height | 4U |
| Form Factor | Rack/Tower |
| Weight (Approximate) | 243.54 lb (110467.89 g) |
| Miscellaneous | |
| Package Contents | Endeavor ED5KRT-5KTF 5000VA Rack/Tower UPS Comm. Cables |
| Energy Star | Yes |
| Energy Efficiency Certification | ENERGY STAR 2.0 |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) 2 |
| Warranty | |
| Limited Warranty | 3 Year |
| Additional Warranty Information | 3 Years (Electronics and Batteries) |
User Manual
FAQ
What is the power capacity of this Minuteman UPS?
The Endeavor ED5KRT-5KTF provides 5000VA (5 kVA) apparent power and 4280W (4.28 kW) real power capacity. This substantial capacity supports multiple servers, network equipment, and critical infrastructure components during power interruptions.
How long will this UPS run on battery power?
Runtime varies by load: approximately 2 minutes at full load (4.28 kW) and 7 minutes at half load (2.14 kW). These runtimes provide sufficient time for orderly shutdowns of protected equipment or continuation of operations during brief utility outages.
Can this UPS be installed in a server rack?
Yes, the unit features a rack/tower design with 4U rack height compatibility. It includes appropriate mounting hardware for secure installation in standard 19-inch server racks, while also supporting standalone tower deployment where rack space is unavailable.
What management interfaces does this UPS include?
Management capabilities include RS-232 serial connectivity for network management systems, USB for direct computer connection, and an EPO (Emergency Power Off) port for integration with safety systems. The LCD display provides real-time status monitoring of power conditions and battery health.
Are the batteries user-replaceable?
Yes, the batteries are both hot-swappable and replaceable. The hot-swappable design allows battery replacement without shutting down connected equipment, while the user-replaceable configuration simplifies maintenance and extends the overall service life of the UPS system.
What input voltages does this UPS accept?
The unit accepts 120 V AC or 230 V AC input with a wide voltage range of 0-300 V AC. This flexibility accommodates various utility power conditions and makes the UPS suitable for deployment in regions with different electrical standards.
What power capacity is listed for this UPS?
The listed power specification is 5 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 120 V AC,230 V AC, which helps position the unit for the right load level and installation role.