Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Minuteman ED6000RTXLMB Endeavor 5556VA Rack/Tower UPS - 4U Double Conversion Online - 208V AC Input - 5. 40 Min Full Load Runtime
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This double conversion online UPS maintains consistent power quality by converting incoming AC to DC and then back to clean AC output, providing complete isolation from utility power anomalies. The 5.56 kVA capacity supports substantial equipment loads while the 208V AC input accommodates commercial power configurations.
The electrical design includes 70 Hz input frequency conversion to 60 Hz output, ensuring compatibility with North American equipment standards. Overload protection safeguards connected devices, while the serial port enables direct monitoring and management capabilities.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The Endeavor ED6000RTXLMB combines high-capacity power protection with flexible deployment options. The rack/tower convertible design eliminates the need for separate mounting kits, while the comprehensive outlet configuration supports mixed equipment types.
Flexible Power Distribution
Multiple receptacle types including NEMA L6-30R, L6-20R, and six NEMA 5-15/20R outlets allow simultaneous support of high-power servers and standard office equipment.
- 1 × NEMA L6-30R
- 1 × NEMA L6-20R
- 6 × NEMA 5-15/20R
Professional Management
SNMP network management provides remote monitoring and control capabilities, while the included SentryHD software offers detailed power analytics and alerting.
- SNMP Manageable
- SentryHD Software Included
- Serial Port Connectivity
Reliable Power Architecture
Double conversion technology ensures clean, stable output regardless of input power quality, with overload protection and isolation stepdown transformer for added safety.
- Double Conversion Online
- Overload Protection
- Isolation Stepdown Transformer
Deployment / Use Cases
This 5.56 kVA UPS is engineered for commercial and industrial applications where power reliability is non-negotiable. The 4U rack-mount profile fits standard server cabinets while the tower configuration option supports standalone installations.
Typical deployments include protecting server racks in data centers, network equipment in telecom closets, and critical systems in healthcare or financial environments. The 208V AC input makes it suitable for three-phase power distribution systems common in commercial buildings.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Data Center Server Protection
Provides backup power for rack-mounted servers, storage arrays, and networking equipment during utility outages or brownouts.
Network Infrastructure Support
Protects switches, routers, and communication equipment in network closets and telecommunications rooms.
Physical Profile
The 4U rack-mount design occupies standard rack space with dimensions of 10.50 inches high, 17.30 inches wide, and 26.20 inches deep. The rack/tower convertible configuration includes foot brackets for tower deployment and a rail kit for rack installation. The compact footprint optimizes data center real estate while providing substantial power capacity.
- Width
- 17.30" (439.42 mm)
- Depth
- 26.20" (665.48 mm)
- Height
- 4U
What's in the Box
The complete package includes all necessary components for immediate deployment and operation.
Highlights
- 5.56 kVA double conversion online UPS with 208V AC input
- 4U rack/tower convertible form factor for flexible deployment
- 5.40 minutes runtime at full load, 10.70 minutes at half load
- Multiple receptacle types: NEMA L6-30R, L6-20R, and six NEMA 5-15/20R
- SNMP network management with SentryHD software included
- Energy Star certified and RoHS 2 compliant
- Overload protection and isolation stepdown transformer
- 3-year limited warranty for long-term reliability
Specifications
| Specifications | |
|---|---|
| Manufacturer | Para Systems, Inc |
| Manufacturer Part Number | ED6000RTXLMB |
| Brand Name | Minuteman |
| Product Line | Endeavor |
| Product Model | ED6000RTXLMB |
| Product Name | Endeavor ED6000RTXLMB 5556VA Rack/Tower UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | NEMA L6-30P |
| Receptacle Type | NEMA L6-30R,NEMA L6-20R,NEMA 5-15/20R |
| Receptacle Detail | 1 x NEMA L6-30R,1 x NEMA L6-20R,6 x NEMA 5-15/20R |
| Overload Protection | Yes |
| Power Description | |
| Load Capacity (VA) | 5.56 kVA |
| Input Voltage | 208 V AC |
| Output Voltage | 208 V AC,212 V AC,120 V AC |
| Input Frequency | 70 Hz |
| Output Frequency | 60 Hz |
| Management | |
| Network Management | SNMP Manageable |
| Interfaces/Ports | |
| Serial Port | Yes |
| Battery Information | |
| Backup/Run Time (Full Load) | 5.40 Minute |
| Backup/Run Time (Half Load) | 10.70 Minute |
| Physical Characteristics | |
| Form Factor | Rack/Tower |
| Rack Height | 4U |
| Height | 10.50" (266.70 mm) |
| Width | 17.30" (439.42 mm) |
| Depth | 26.20" (665.48 mm) |
| Miscellaneous | |
| Package Contents | Endeavor ED6000RTXLMB 5556VA Rack/Tower UPS Rail Kit Foot Brackets 1 x Battery Pack Maintenance Bypass Switch Isolation Stepdown Transformer |
| Software Included | SentryHD |
| Energy Star | Yes |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) 2 |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the power capacity of this Minuteman UPS?
The Endeavor ED6000RTXLMB provides 5.56 kVA (kilovolt-ampere) of power capacity. This substantial capacity supports multiple servers, networking equipment, and critical systems during power events, making it suitable for rack-mounted deployments in data centers and server rooms.
How long will this UPS run at full load during a power outage?
At full load, this UPS provides 5.40 minutes of runtime. At half load, the runtime extends to 10.70 minutes. These runtime figures allow for orderly shutdown of connected equipment or temporary operation until power is restored or generators come online.
What input voltage does this UPS require?
This UPS requires 208V AC input voltage. This voltage is common in commercial three-phase power systems and makes the unit suitable for data centers, server rooms, and other commercial installations with 208V power distribution.
What types of outlets does this UPS include?
The UPS includes multiple receptacle types: one NEMA L6-30R, one NEMA L6-20R, and six NEMA 5-15/20R outlets. This configuration supports a mix of high-power equipment (servers, switches) and standard office devices (computers, monitors) simultaneously.
Can this UPS be mounted in a standard server rack?
Yes, this UPS features a rack/tower convertible design. It occupies 4U of rack space and includes a rail kit for standard 19-inch server rack installation. The unit also includes foot brackets for standalone tower deployment when rack mounting isn't required.
What management capabilities does this UPS offer?
The UPS supports SNMP network management for remote monitoring and control. It includes a serial port for direct connectivity and comes with SentryHD software for detailed power analytics, alerting, and configuration management across the network.
What power capacity is listed for this UPS?
The listed power specification is 5.56 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 208 V AC, which helps position the unit for the right load level and installation role.