Product Features
Technical Overview
The ED6200RTXL operates on double conversion online topology, continuously converting incoming AC power to DC and back to clean AC output, ensuring complete isolation from utility power anomalies. This technology provides zero transfer time during power transitions and maintains consistent output voltage and frequency regardless of input conditions.
The UPS accepts 208V AC input at 70Hz and delivers regulated 208V AC or 212V AC output at 60Hz, making it compatible with North American three-phase power systems. It features hardwired NEMA L6-30P connector type with built-in overload protection for enhanced safety and reliability.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Overload Protection, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The Endeavor ED6200RTXL combines robust power protection with flexible deployment options and comprehensive management capabilities. Its double conversion technology ensures maximum equipment protection against all nine common power problems, including surges, sags, harmonics, and frequency variations.
Enterprise-Grade Protection
Complete isolation from utility power issues with zero transfer time ensures continuous operation of critical equipment.
- Double conversion topology
- Voltage and frequency regulation
- Overload protection
Flexible Deployment
Configure as either a rack-mounted 4U unit or free-standing tower to match your infrastructure requirements.
- 4U rack height
- Included rail kit
- Foot brackets for tower use
Comprehensive Management
SNMP management capability enables remote monitoring and control through network management systems.
- SNMP manageable
- Serial port connectivity
- SentryHD software included
Deployment / Use Cases
The ED6200RTXL is engineered for environments requiring reliable power protection for critical infrastructure. Its 6000VA capacity and double conversion technology make it suitable for protecting multiple servers, network switches, storage arrays, and telecommunications equipment in data centers, server rooms, and network closets.
The rack/tower flexibility allows deployment in standard 19-inch server racks for space-optimized installations or as a standalone tower in locations without rack infrastructure. The unit's 208V AC compatibility makes it ideal for three-phase power environments commonly found in commercial and industrial facilities.
Data Center Protection
Safeguard server racks and networking equipment with clean, regulated power and sufficient runtime for backup systems to engage.
Telecommunications Infrastructure
Protect voice and data communication equipment from power disturbances that can cause service interruptions and equipment damage.
Physical Profile
The ED6200RTXL measures 7" (177.80 mm) in height, 17.30" (439.42 mm) in width, and 26" (660.40 mm) in depth, occupying 4U of vertical space in standard 19-inch server racks. The compact design maximizes power density while maintaining adequate ventilation for optimal thermal management. The unit includes both rack-mount rails and foot brackets, allowing quick conversion between rack and tower configurations without additional hardware.
- Width
- 17.30" (439.42 mm)
- Depth
- 26" (660.40 mm)
- Height
- 4U
What's in the Box
The ED6200RTXL ships complete with all necessary components for immediate deployment in either rack or tower configuration.
Highlights
- 6000VA double conversion online UPS for maximum power protection
- 4U rack/tower form factor with included mounting hardware
- 5.4 minutes runtime at full load, 10.7 minutes at half load
- 208V AC input with 208V/212V AC output compatibility
- SNMP manageable for remote monitoring and control
- Hardwired NEMA L6-30P connector with overload protection
- Energy Star certified for energy efficiency
- RoHS 2 compliant for environmental safety
- 3-year limited warranty for long-term reliability
- Includes SentryHD management software
Specifications
| Specifications | |
|---|---|
| Manufacturer | Para Systems, Inc |
| Manufacturer Part Number | ED6200RTXL |
| Brand Name | Minuteman |
| Product Line | Endeavor |
| Product Model | ED6200RTXL |
| Product Name | Endeavor ED6200RTXL 6000VA Rack/Tower UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | NEMA L6-30P |
| Receptacle Type | Hardwired |
| Overload Protection | Yes |
| Power Description | |
| Load Capacity (VA) | 6 kVA |
| Input Voltage | 208 V AC |
| Output Voltage | 208 V AC,212 V AC |
| Input Frequency | 70 Hz |
| Output Frequency | 60 Hz |
| Management | |
| Network Management | SNMP Manageable |
| Interfaces/Ports | |
| Serial Port | Yes |
| Battery Information | |
| Backup/Run Time (Full Load) | 5.40 Minute |
| Backup/Run Time (Half Load) | 10.70 Minute |
| Physical Characteristics | |
| Form Factor | Rack/Tower |
| Rack Height | 4U |
| Height | 7" (177.80 mm) |
| Width | 17.30" (439.42 mm) |
| Depth | 26" (660.40 mm) |
| Miscellaneous | |
| Package Contents | Endeavor ED6200RTXL 6000VA Rack/Tower UPS Rail Kit Foot Brackets 1 x Battery Pack |
| Software Included | SentryHD |
| Energy Star | Yes |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) 2 |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the power capacity of the Minuteman ED6200RTXL UPS?
The ED6200RTXL provides 6000VA (6 kVA) of power capacity, making it suitable for protecting multiple servers, networking equipment, or telecommunications infrastructure in commercial and industrial environments.
How long will this UPS run on battery power?
At full load, the ED6200RTXL provides 5.4 minutes of runtime, while at half load it extends to 10.7 minutes. This provides sufficient time for graceful shutdowns or for backup generators to engage during power outages.
What input and output voltages does this UPS support?
The UPS accepts 208V AC input and delivers either 208V AC or 212V AC output, making it compatible with North American three-phase power systems commonly used in commercial and industrial facilities.
Can this UPS be installed in a server rack?
Yes, the ED6200RTXL is designed for both rack and tower deployment. It occupies 4U of vertical space in standard 19-inch server racks and includes a complete rail kit for secure rack mounting, along with foot brackets for tower configuration.
What management capabilities does this UPS offer?
The UPS supports SNMP management for remote monitoring and control through network management systems. It also includes a serial port and comes with SentryHD software for comprehensive power management and monitoring.
What type of power protection technology does this UPS use?
The ED6200RTXL utilizes double conversion online topology, which continuously converts incoming AC power to DC and back to clean AC output. This provides complete isolation from utility power issues and ensures zero transfer time during power transitions.
What power capacity is listed for this UPS?
The listed power specification is 6 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 208 V AC, which helps position the unit for the right load level and installation role.