Minuteman ED8200RTXLMB Endeavor 8000VA Double Conversion Online UPS - 6U Rack/Tower - 208V AC Input/Output - 7. 8 Min Full Load Runtime
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This double conversion online UPS continuously converts incoming AC power to DC, then back to clean AC, providing complete isolation from utility power issues. It accepts 208V AC input at 70 Hz and delivers regulated 208V or 212V AC output at a stable 60 Hz frequency, ensuring compatibility with standard North American three-phase equipment.
The unit features a serial port for direct device communication and supports SNMP management for remote monitoring and control via network infrastructure. Its battery system delivers 7.80 minutes of runtime at full load and extends to 14.20 minutes at half load, providing adequate time for graceful shutdowns or generator transfer.
Power Quality Protection
Double conversion technology eliminates transfer time during outages and provides complete protection against surges, sags, spikes, and frequency variations.
- Zero transfer time
- Voltage regulation
- Frequency stabilization
Key Product Advantages
The Endeavor ED8200RTXLMB combines industrial-grade power protection with deployment flexibility, making it ideal for environments where uptime is non-negotiable. Its dual rack/tower design allows installation in standard 19-inch racks or as a standalone tower, adapting to space constraints without compromising performance.
Management & Monitoring
Includes SentryHD management software for real-time monitoring, configuration, and alerts. SNMP capability enables integration with existing network management systems.
- SentryHD software included
- SNMP manageable
- Serial port for direct connection
Environmental Compliance
Meets Energy Star efficiency standards and complies with RoHS 2 environmental regulations, reducing energy consumption and hazardous materials.
- Energy Star certified
- RoHS 2 compliant
- Environmentally friendly design
Deployment / Use Cases
This 8000VA UPS is engineered for medium to large-scale IT deployments requiring reliable backup power. Its capacity and runtime make it suitable for protecting server racks, network switches, storage arrays, and telecommunications equipment in commercial and industrial settings.
The hardwired configuration is ideal for permanent installations where outlet-based connections are impractical or insufficient. Data centers can deploy multiple units in rack configurations, while smaller server rooms may utilize the tower form factor for easier access and maintenance.
Data Center Protection
Provides backup power for critical servers and networking equipment during utility failures, allowing time for controlled shutdown or generator startup.
- Server rack protection
- Network equipment backup
- Generator bridging
Industrial Applications
Suitable for manufacturing environments, healthcare facilities, and financial institutions where power continuity is essential for operations and compliance.
- Medical equipment support
- Industrial control systems
- Financial transaction processing
Physical Profile
The UPS measures 10.28" (261.11 mm) in height, 17.30" (439.42 mm) in width, and 24.60" (624.84 mm) in depth, occupying 6U of rack space. This compact footprint maximizes power density in rack environments while maintaining adequate ventilation. The included rail kit and foot brackets facilitate secure installation in either rack or tower orientation.
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 6U, 17.30" (439.42 mm), 24.60" (624.84 mm). This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 17.30" (439.42 mm)
- Depth
- 24.60" (624.84 mm)
- Height
- 6U
What's in the Box
The package includes all necessary components for immediate deployment and management.
Highlights
- 8000VA (8 kVA) double conversion online UPS
- 6U rack/tower form factor with flexible deployment options
- 7.80-minute runtime at full load, 14.20 minutes at half load
- 208V AC input with 208V/212V AC output
- SNMP manageable with included SentryHD software
- Hardwired connections for secure permanent installation
- Energy Star certified and RoHS 2 compliant
- Includes rail kit, foot brackets, and maintenance bypass switch
- 3-year limited warranty
Specifications
| Specifications | |
|---|---|
| Manufacturer | Para Systems, Inc |
| Manufacturer Part Number | ED8200RTXLMB |
| Brand Name | Minuteman |
| Product Line | Endeavor |
| Product Model | ED8200RTXLMB |
| Product Name | Endeavor ED8200RTXLMB 8000VA Rack/Tower UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | Hardwired |
| Receptacle Type | Hardwired |
| Overload Protection | Yes |
| Power Description | |
| Load Capacity (VA) | 8 kVA |
| Input Voltage | 208 V AC |
| Output Voltage | 208 V AC,212 V AC |
| Input Frequency | 70 Hz |
| Output Frequency | 60 Hz |
| Management | |
| Network Management | SNMP Manageable |
| Interfaces/Ports | |
| Serial Port | Yes |
| Battery Information | |
| Backup/Run Time (Full Load) | 7.80 Minute |
| Backup/Run Time (Half Load) | 14.20 Minute |
| Physical Characteristics | |
| Form Factor | Rack/Tower |
| Rack Height | 6U |
| Height | 10.28" (261.11 mm) |
| Width | 17.30" (439.42 mm) |
| Depth | 24.60" (624.84 mm) |
| Miscellaneous | |
| Package Contents | Endeavor ED8200RTXLMB 8000VA Rack/Tower UPS Rail Kit Foot Brackets 1 x Battery Pack Maintenance Bypass Switch |
| Software Included | SentryHD |
| Energy Star | Yes |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) 2 |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the power capacity of this Minuteman UPS?
The Minuteman Endeavor ED8200RTXLMB has a load capacity of 8000VA (8 kVA). This rating indicates the maximum apparent power the UPS can deliver to connected equipment, making it suitable for medium to large server racks, network infrastructure, and industrial applications requiring substantial backup power.
How long will this UPS run at full load during a power outage?
At full load, this UPS provides 7.80 minutes of runtime. At half load, runtime extends to 14.20 minutes. These durations allow sufficient time for graceful shutdown of protected equipment or for backup generators to start and stabilize, minimizing disruption to critical operations.
What input and output voltages does this UPS support?
The UPS accepts 208V AC input and delivers either 208V or 212V AC output. This voltage range is standard for North American three-phase power systems, making the unit compatible with commercial and data center equipment designed for 208V operation.
Can this UPS be installed in both rack and tower configurations?
Yes, the Endeavor ED8200RTXLMB supports both rack-mount and tower deployments. It occupies 6U of rack space and includes a rail kit for rack installation along with foot brackets for tower placement. This flexibility allows adaptation to various IT environments and space constraints.
What management capabilities does this UPS offer?
The UPS includes SNMP management for network-based monitoring and control, plus a serial port for direct device communication. SentryHD management software is included, providing real-time monitoring, configuration tools, and alerting capabilities to maintain visibility and control over power status.
What is included in the package with this UPS?
The package contains the Endeavor ED8200RTXLMB 8000VA UPS unit, a rail kit for rack mounting, foot brackets for tower placement, one battery pack, a maintenance bypass switch, and SentryHD management software. These components support immediate deployment in either rack or tower configuration.
What power capacity is listed for this UPS?
The listed power specification is 8 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 208 V AC, which helps position the unit for the right load level and installation role.