Technical Overview
This double conversion online UPS continuously converts incoming AC power to DC and back to clean AC output, providing complete isolation from utility power anomalies. The unit achieves 90% efficiency in AC mode, 96% in Eco mode, and 87% in battery mode, balancing performance with energy conservation.
With a 0.99 input power factor and pure sine wave output, the END1000RT2U-LNC maintains compatibility with sensitive electronic equipment including servers, networking gear, medical devices, and security systems. The unit accepts input frequencies from 40-70Hz and delivers output frequencies from 47-63Hz, accommodating various power grid standards.
This section brings together practical product details such as Transfer Time, Phase, Efficiency Detail, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The END1000RT2U-LNC combines industrial-grade power protection with flexible deployment options, offering both rack-mount and tower configurations in a single unit. The built-in bypass switch allows for maintenance without power interruption, while the cold start function enables operation from battery power when utility power is unavailable.
Advanced Battery Technology
Lithium iron phosphate (LiFePO4) batteries offer longer lifespan, faster recharge times, and better thermal stability compared to traditional lead-acid batteries, with a typical recharge time of just 2 hours.
- 5-year warranty includes batteries
- Single battery configuration
- Maintenance-friendly design
Comprehensive Management
LCD display provides real-time status monitoring, while Smart RS-232/USB and network card options enable remote management and monitoring through enterprise power management software.
- EPO port for emergency shutdown
- Serial and USB connectivity
- Network management ready
Deployment / Use Cases
This UPS is engineered for critical infrastructure applications where power continuity is non-negotiable. The 2U form factor makes it ideal for standard server racks while maintaining sufficient capacity for small to medium server loads, network equipment, or medical devices.
In healthcare settings, the pure sine wave output ensures compatibility with sensitive medical equipment, while the wide operating temperature range (32°F to 104°F) and humidity tolerance (20% to 95%) support deployment in various environmental conditions. For edge computing and telecommunications applications, the unit's compact footprint and dual voltage support enable deployment in distributed locations with varying power infrastructures.
Server Room Protection
Provides 12 minutes of runtime at full load for critical servers, allowing for graceful shutdown or continued operation during brief outages. The 900W capacity supports typical 1U-2U server configurations with room for networking equipment.
Network Infrastructure
Protects switches, routers, and access points in network closets and telecommunications rooms. The wide input voltage range (55V-265V) accommodates varying power quality across different locations.
Physical Profile
Measuring 3.50" (88.90 mm) in height, 17.20" (436.88 mm) in width, and 16.10" (408.94 mm) in depth, this UPS occupies 2U of standard 19" rack space. The 23.80 lb weight facilitates installation in both rack and tower configurations, with mounting hardware included for rack deployment. The compact design maximizes power density while maintaining serviceability through front-accessible components.
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 3.50" (88.90 mm), 17.20" (436.88 mm), 16.10" (408.94 mm), 23.80 lb (10795.50 g). This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 17.20" (436.88 mm)
- Depth
- 16.10" (408.94 mm)
- Height
- 3.50" (88.90 mm)
- Weight
- 23.80 lb (10795.50 g)
Highlights
- 1000VA/900W double conversion online UPS with pure sine wave output
- 12 minutes runtime at full load, 25 minutes at half load
- 2U rack/tower form factor with flexible deployment options
- Lithium iron phosphate (LiFePO4) battery with 2-hour recharge time
- Supports 120V and 230V input voltages with wide input ranges
- LCD display with Smart RS-232/USB and network management capabilities
- Hot-swappable battery for maintenance without downtime
- 5-year product warranty including batteries
- Built-in bypass switch and cold start function
- Operates in temperatures from 32°F to 104°F (0°C to 40°C)
Specifications
| Specifications | |
|---|---|
| Manufacturer | Para Systems, Inc |
| Manufacturer Part Number | END1000RT2U-LNC |
| Brand Name | Minuteman |
| Product Line | Endurance |
| Product Model | END1000RT2U-LNC |
| Product Name | Endurance END1000RT2U-LNC 1000VA Rack/Tower UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Transfer Time | 0 ns |
| Phase | Single Phase |
| Efficiency Detail | 90% (AC Mode),96% (Eco Mode),87% (Battery Mode) |
| Application/Usage | IT Infrastructure,Business,Server,Network,Telecommunication,Equipment,Voice/Data Network,Healthcare,Medical Laboratory,Light Industrial Application,Edge Computing,Medical,Security,Access Control,Education,Government |
| Features | Built-in Bypass Switch,Cold Start Function |
| Power Description | |
| Load Capacity (VA) | 1 kVA |
| Load Capacity (Watt) | 900 W |
| Input Voltage | 120 V AC,230 V AC |
| Input Voltage Range | 160 V AC - 265 V AC,80 V AC - 140 V AC,55 V AC - 160 V AC |
| Output Voltage | 100 V AC,110 V AC,115 V AC,120 V AC,125 V AC,127 V AC |
| Input Frequency | 40 Hz,70 Hz |
| Output Frequency | 47 Hz,53 Hz,57 Hz,63 Hz,50 Hz,60 Hz |
| Waveform Type | Pure Sine Wave |
| Input Power Factor | 0.99 |
| Display & Graphics | |
| Display | LCD |
| Management | |
| Network Management | Smart RS-232/USB,Network Card |
| Interfaces/Ports | |
| Serial Port | Yes |
| USB | Yes |
| EPO Port | Yes |
| Battery Information | |
| Number of Batteries | 1 |
| Battery Chemistry | Lithium Iron Phosphate (LiFePO4) |
| Backup/Run Time (Full Load) | 12 Minute |
| Backup/Run Time (Half Load) | 25 Minute |
| Hot Swappable | Yes |
| Typical Battery Recharge Time | 2 Hour |
| Environmental Conditions | |
| Operating Humidity | 20% - 95% |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Operating Temperature | 104°F (40°C) |
| Physical Characteristics | |
| Height | 3.50" (88.90 mm) |
| Width | 17.20" (436.88 mm) |
| Depth | 16.10" (408.94 mm) |
| Rack Height | 2U |
| Form Factor | Rack/Tower |
| Weight (Approximate) | 23.80 lb (10795.50 g) |
| Warranty | |
| Limited Warranty | 5 Year |
| Additional Warranty Information | 5-year product warranty, including batteries |
User Manual
FAQ
What is the runtime of this UPS at full load?
The Minuteman END1000RT2U-LNC provides 12 minutes of backup runtime at full 900W load. At half load (450W), runtime extends to 25 minutes. These figures are based on the lithium iron phosphate battery technology and double conversion topology that maximizes efficiency during battery operation.
Can this UPS be used in both rack and tower configurations?
Yes, this unit features a rack/tower form factor designed for flexible deployment. It occupies 2U of standard 19" rack space with dimensions of 3.50" H x 17.20" W x 16.10" D, and includes the necessary hardware for rack mounting. The 23.80 lb weight makes it manageable for both rack installation and standalone tower use.
What input voltages does this UPS support?
This UPS accepts both 120V AC and 230V AC input voltages, with wide input ranges of 80-140V AC for 120V operation and 160-265V AC for 230V operation. An additional 55-160V AC range provides compatibility with various power quality conditions. This dual-voltage capability makes the unit suitable for North American and international deployments.
What type of battery technology does this UPS use?
The END1000RT2U-LNC utilizes lithium iron phosphate (LiFePO4) battery chemistry, which offers advantages over traditional lead-acid batteries including longer lifespan, faster recharge times (typically 2 hours), better thermal stability, and reduced maintenance requirements. The single battery configuration is hot-swappable for maintenance without power interruption.
What management and monitoring options are available?
This UPS includes an LCD display for local status monitoring and supports Smart RS-232/USB connectivity for basic management. For network integration, a network card option enables remote monitoring and management through enterprise power management software. The unit also features an EPO (Emergency Power Off) port for integration with building safety systems.
What is the warranty coverage for this UPS?
Minuteman provides a 5-year product warranty that includes coverage for the lithium iron phosphate batteries. This comprehensive warranty reflects the reliability of the double conversion design and advanced battery technology. The warranty covers defects in materials and workmanship under normal operating conditions within the specified temperature and humidity ranges.
What power capacity is listed for this UPS?
The listed power specification is 1 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 120 V AC,230 V AC, which helps position the unit for the right load level and installation role.