Sidebar Sidebar Sidebar
sale
Sold out

Shipping included*

Panduit P30D02G G6 Monitored PDU - 30 Outlets - 18x C13 - 6x C19 - 6x NEMA 5-20R - 8. 6 kW - 230V AC - 3-Phase - Rack-Mount

SKU: P30D02G
(No reviews) Write a Review
MSRP: $2,651.99
$2,651.99
$2,363.99
Save: $288.00 (10.86%)
Warranty Information: 3 Year
Condition: New
Width: 5.08 (cm)
Height: 1.23 (cm)
Depth: 5.33 (cm)

Ask for ETA! 🗨️

Logo cards
B2B Pricing

Business volume discounts

IT Experts

Technical guidance

IT Configuration

Preparation & staging

Canada Stock

QC · ON · AB · BC

Product Features

Description

Product Overview

The Panduit G6 Monitored PDU (P30D02G) delivers reliable three-phase power distribution for enterprise server racks and data center environments. This 30-outlet unit combines high-density connectivity with remote monitoring capabilities, providing IT administrators with real-time visibility into power consumption and electrical parameters.

Designed for vertical rack mounting, the PDU features a compact 2-inch width that maximizes space efficiency in standard 19-inch racks. The black finish and clean cable management support professional installation in commercial data centers, colocation facilities, and enterprise server rooms where power monitoring and load balancing are critical operational requirements.

This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.

Power
8.60 kW
Power Capacity
230 V AC40U
Power Capacity & Electrical
Power Rating8.60 kW
Input Voltage230 V AC
Output Voltage208 V AC
Outlet Configuration
Total Outlets30
Receptacle Types18 x IEC 60320 C13, 6 x IEC 60320 C19, 6 x NEMA 5-20R
Connectivity & Management
Management ProtocolSNMP
Network PortRJ-45
DisplayOnboard Display
Physical Installation
Mount TypeRack-mountable
Rack Height40U
Cord Length10 ft (3.05 m)

Technical Overview

This monitored PDU handles 8.6 kW of continuous power with 230V AC input and 208V AC output, supporting three-phase electrical systems commonly found in commercial power infrastructure. The 30A input current and 60 Hz frequency compatibility ensure stable operation in North American power environments.

Network connectivity via RJ-45 enables SNMP management for integration with existing monitoring systems, while the onboard display provides local visibility of voltage, frequency, and load levels without requiring network access.

This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.

A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.

Input Current30 A
Input Frequency60 Hz
Phase ConfigurationThree Phase
NEMA L21-30P PlugThree-Phase PowerSNMP Management

Key Product Advantages

The G6 Monitored PDU provides data center managers with actionable power intelligence while maintaining high outlet density in a space-efficient form factor. Remote monitoring capabilities transform basic power distribution into a managed infrastructure component.

Comprehensive Outlet Mix

With 18 C13, 6 C19, and 6 NEMA 5-20R receptacles, this PDU supports diverse equipment from servers and switches to networking gear and peripheral devices without requiring additional adapters.

  • 18 IEC C13 outlets for standard server PSUs
  • 6 IEC C19 outlets for high-power equipment
  • 6 NEMA 5-20R outlets for 120V devices

Dual Monitoring Interface

Both local display and remote SNMP access provide flexibility for power management, allowing technicians to check status at the rack while enabling centralized monitoring through network management systems.

  • Onboard LCD for local status checks
  • SNMP for integration with NMS
  • Real-time voltage and load monitoring

Deployment / Use Cases

This monitored PDU is engineered for environments where power visibility and high-density connectivity are operational priorities. The three-phase power handling and extensive outlet configuration make it suitable for fully populated server racks in data centers that require detailed power monitoring for capacity planning and load balancing.

IT teams deploying this PDU gain the ability to track power consumption at the rack level, identify underutilized circuits, and prevent overload conditions before they cause downtime. The vertical mounting orientation and 40U rack height compatibility ensure seamless integration with standard cabinet installations.

Data Center Server Racks

Ideal for fully populated server cabinets where monitoring individual circuit loads helps optimize power distribution and prevent circuit overloads in high-density computing environments.

Colocation Facility Installations

Provides tenants with power visibility while giving facility operators SNMP access for monitoring without physical access to customer cabinets, supporting remote management requirements.

Physical Profile

The vertical rack-mount design occupies minimal horizontal space with a 2-inch width, while the 69-inch height fits standard 40U racks. The slim profile preserves valuable rack real estate for equipment while providing full-length power distribution. The 10-foot power cord offers flexible placement options within the data center, and the black finish maintains a professional appearance in visible installations.

Color
Black
Dimensions
Width
2" (50.80 mm)
Depth
2.10" (53.34 mm)
Height
40U
Length
10 ft (3.05 m)
Dimensions69" H × 2" W × 2.10" D
Weight CapacityRack-mountable

What's in the Box

The package includes everything needed for immediate rack installation and operation.

Package contents include G6 30-Outlets PDU Mounting Hardware, G6 30-Outlets PDU. These included items support setup, installation, and immediate deployment without needing to source the core bundled accessories separately.

G6 30-Outlets PDU Mounting Hardware
G6 30-Outlets PDU
[custom-highlights]

Highlights

  • 30 total outlets with mixed receptacle types for equipment flexibility
  • 8.6 kW power capacity supports high-density server racks
  • Three-phase 230V AC input with 208V AC output
  • SNMP management enables remote power monitoring
  • Onboard display provides local status visibility
  • Vertical rack-mount design with 40U height compatibility
  • NEMA L21-30P plug for three-phase power connections
  • 10-foot power cord for installation flexibility
  • Black finish for professional data center appearance
  • 3-year limited warranty for long-term reliability
[/custom-highlights][custom-specifications]

Specifications

Specifications
ManufacturerPANDUIT CORP
Manufacturer Part NumberP30D02G
Brand NamePanduit
Product SeriesG6
Product NameG6 30-Outlets PDU
Packaged Quantity1
Product TypePDU
Technical Information
PDU TypeMonitored
PhaseThree Phase
Plug/Connector TypeNEMA L21-30P
Receptacle TypeIEC 60320 C13,IEC 60320 C19,NEMA 5-20R
Receptacle Detail18 x IEC 60320 C13,6 x IEC 60320 C19,6 x NEMA 5-20R
FeaturesOnboard Display
Load Capacity (Watt)8.60 kW
Power Description
Input Voltage230 V AC
Output Voltage208 V AC
Power Rating (Watt)8.60 kW
Input Current30 A
Input Frequency60 Hz
Management
ManagementSNMP
Interfaces/Ports
Network (RJ-45)Yes
Physical Characteristics
Product ColorBlack
Mounting OrientationVertical
Mount TypeRack-mountable
Rack Height40U
Cord Length10 ft (3.05 m)
Height69" (1752.60 mm)
Width2" (50.80 mm)
Depth2.10" (53.34 mm)
Environmental Conditions
Minimum Operating Temperature50°F (10°C)
Maximum Operating Temperature140°F (60°C)
Minimum Storage Temperature24.8°F (-4°C)
Maximum Storage Temperature284°F (140°C)
Miscellaneous
Package ContentsG6 30-Outlets PDU Mounting Hardware
Warranty
Limited Warranty3 Year
[/custom-specifications][custom-user-manual]

User Manual

This section contains official documentation provided by the manufacturer, including product manuals, brochures, and supplementary materials.
[/custom-user-manual][custom-faq]

FAQ

What types of equipment can I connect to this PDU's different outlets?

The PDU supports diverse equipment: 18 IEC C13 outlets connect standard server power supplies and networking gear; 6 IEC C19 outlets handle high-power devices like blade chassis and large UPS units; 6 NEMA 5-20R outlets accommodate 120V equipment including monitors, KVM switches, and peripheral devices. This mix eliminates the need for adapters in most rack configurations.

How does the monitoring functionality work on this PDU?

Monitoring occurs through both local and remote interfaces. The onboard display shows real-time voltage, frequency, and load levels at the rack. For network integration, the RJ-45 port supports SNMP management, allowing integration with network monitoring systems to track power metrics centrally and receive alerts for abnormal conditions.

What rack configuration does this PDU support for installation?

This is a vertical-mount PDU designed for standard 19-inch racks with 40U height compatibility. The 2-inch width minimizes space consumption while providing full-length power distribution. Mounting hardware is included for secure installation in server cabinets and data center racks.

What power input does this PDU require for operation?

The PDU requires a three-phase 230V AC power source with a NEMA L21-30P connection. It outputs 208V AC to connected equipment. The 30A input current and 60Hz frequency ensure compatibility with commercial North American power infrastructure commonly found in data centers.

Can I manage this PDU remotely without physical access?

Yes, remote management is enabled through SNMP over the RJ-45 network connection. This allows IT administrators to monitor voltage, frequency, and load levels from a network operations center, configure alerts for threshold violations, and integrate power data with existing infrastructure management platforms.

What environmental conditions can this PDU operate within?

The PDU operates between 50°F and 140°F (10°C to 60°C) and stores between 24.8°F and 284°F (-4°C to 140°C). These ranges accommodate typical data center environments while ensuring reliable performance in controlled climate conditions where rack temperatures remain within specified limits.

What power capacity is listed for this UPS?

The listed power specification is 8.60 kW, which helps position the unit for the right load level and installation role.

What voltage details are listed?

The listed power specification is 230 V AC, which helps position the unit for the right load level and installation role.

[/custom-faq]
Volume Discounts
Qty Price Available
Match Price Request

Found a lower price? Send us the link and we will do our best to match or beat it.

Request received. We will reply within 24 hours.
Fleet Network
Wholesale & B2B
Partner with Us

Looking to buy in bulk? We offer competitive pricing, dedicated support, and custom solutions for businesses of all sizes.

Volume Discounts

Tiered pricing structure designed to maximize your margins as you grow.

Dedicated Account Manager

Direct access to a specialist who understands your business needs.

Fast & Reliable Shipping

Priority processing and discounted shipping rates for bulk orders.

Request a Quote
Thank you!
Your request has been sent successfully.
Panduit P30D02G G6 Monitored PDU - 30 Outlets - 18x C13 - 6x C19 - 6x NEMA 5-20R - 8. 6 kW - 230V AC - 3-Phase - Rack-Mount
MSRP: $2,651.99
$2,651.99
$2,363.99
Save: $288.00 (10.86%)
Out of stock