Panduit P42G20G G6 42-Outlet Monitored Switched PDU - 17. 3 kW - 230V AC Input - 208V AC Output - 21 x C13/C15 & 21 x C13/C15/C19/C21 Outlets - 0U
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This monitored and switched PDU operates with 230V AC input voltage and delivers 208V AC output voltage across its 42 outlets. The three-phase power distribution supports 50A input current at 60Hz frequency, providing stable power delivery for high-density server deployments.
The receptacle configuration includes 21 IEC 60320 C13/C15 outlets and 21 mixed C13/C15/C19/C21 outlets, offering flexibility for various equipment power connections. The IEC 60309 3P+E 9H 60A plug ensures secure connection to three-phase power sources.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The G6 series PDU provides data center managers with comprehensive power monitoring and control capabilities that enhance operational efficiency and prevent overload conditions. The combination of high outlet density and intelligent management features makes this unit ideal for modern data center power distribution.
Intelligent Power Management
SNMP connectivity enables remote monitoring of power consumption, outlet status, and environmental sensors. The onboard display provides local visibility into critical power metrics without requiring network access.
- Remote monitoring via SNMP
- Local status display
- Outlet-level control capabilities
High-Density Configuration
With 42 outlets in a 0U form factor, this PDU maximizes power distribution capacity without consuming valuable rack space. The mixed receptacle types accommodate diverse equipment requirements.
- 42 total outlets
- Mixed C13/C15/C19/C21 types
- Space-efficient 0U design
Deployment / Use Cases
This PDU is engineered specifically for data center environments where reliable power distribution and monitoring are critical. The 17.3 kW capacity supports high-density server racks, network equipment cabinets, and storage arrays in enterprise and colocation facilities.
The vertical 0U mounting design makes it ideal for installation in standard 19-inch server racks alongside equipment. The compact profile allows for deployment in space-constrained environments while providing extensive outlet coverage for multiple devices.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Data Center Server Racks
Provide power to high-density server deployments with intelligent monitoring to prevent circuit overload and optimize power utilization across multiple devices.
Network Equipment Cabinets
Distribute power to switches, routers, and other networking gear while maintaining visibility into power consumption and outlet status through SNMP management.
Physical Profile
The PDU features a vertical rack-mountable design with dimensions of 72" height × 2.20" width × 3" depth (1828.80 × 55.88 × 76.20 mm). The 0U rack height configuration preserves valuable rack space for equipment while the 15 lb weight ensures manageable installation. The black metal construction provides durability in data center environments, and the 10-foot power cord offers flexible placement options within racks.
- Width
- 2.20" (55.88 mm)
- Depth
- 3" (76.20 mm)
- Height
- 0U
- Weight
- 15 lb (6803.89 g)
- Length
- 10 ft (3.05 m)
What's in the Box
The package includes the G6 42-Outlets PDU unit along with all necessary mounting hardware for secure rack installation.
Package contents include G6 42-Outlets PDU Mounting Hardware, G6 42-Outlets PDU. These included items support setup, installation, and immediate deployment without needing to source the core bundled accessories separately.
Highlights
- 42 total outlets with mixed C13/C15/C19/C21 configurations
- 17.3 kW power capacity for high-density deployments
- SNMP management with onboard display for monitoring
- 0U vertical rack-mountable design saves space
- Three-phase 230V AC input to 208V AC output
- 50A input current at 60Hz frequency
- Black metal construction for durability
- 10-foot power cord for flexible placement
- Operating temperature range: 50°F to 140°F (10°C to 60°C)
- 3-year limited warranty
Specifications
| Specifications | |
|---|---|
| Manufacturer | PANDUIT CORP |
| Manufacturer Part Number | P42G20G |
| Brand Name | Panduit |
| Product Series | G6 |
| Product Name | G6 42-Outlets PDU |
| Packaged Quantity | 1 |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Monitored,Switched |
| Phase | Three Phase |
| Plug/Connector Type | IEC 60309 3P+E 9H 60A |
| Receptacle Type | IEC 60320 C13/C15,IEC 60320 C13/C15/C19/C21 |
| Receptacle Detail | 21 x IEC 60320 C13/C15,21 x IEC 60320 C13/C15/C19/C21 |
| Features | Onboard Display |
| Load Capacity (Watt) | 17.30 kW |
| Power Description | |
| Input Voltage | 230 V AC |
| Output Voltage | 208 V AC |
| Power Rating (Watt) | 17.30 kW |
| Input Current | 50 A |
| Input Frequency | 60 Hz |
| Management | |
| Management | SNMP |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Color Family | Black |
| Product Color | Black |
| Product Material | Metal |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Rack Height | 0U |
| Cord Length | 10 ft (3.05 m) |
| Height | 72" (1828.80 mm) |
| Width | 2.20" (55.88 mm) |
| Depth | 3" (76.20 mm) |
| Weight (Approximate) | 15 lb (6803.89 g) |
| Environmental Conditions | |
| Minimum Operating Temperature | 50°F (10°C) |
| Maximum Operating Temperature | 140°F (60°C) |
| Minimum Storage Temperature | 24.8°F (-4°C) |
| Maximum Storage Temperature | 284°F (140°C) |
| Miscellaneous | |
| Package Contents | G6 42-Outlets PDU Mounting Hardware |
| Application/Usage | Data Center |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the power capacity of this PDU?
The Panduit P42G20G PDU has a 17.3 kW power rating, providing substantial capacity for high-density server racks and network equipment in data center environments. This three-phase unit can handle significant power loads while maintaining stable distribution across all 42 outlets.
How many outlets does this PDU have and what types?
This PDU features 42 total outlets with a mixed configuration: 21 IEC 60320 C13/C15 outlets and 21 mixed C13/C15/C19/C21 outlets. This combination provides flexibility for connecting various server, storage, and networking equipment with different power connector requirements.
What management capabilities does this PDU offer?
The PDU includes SNMP management for remote monitoring of power consumption, outlet status, and environmental conditions. It also features an onboard display for local visibility without network access, allowing administrators to monitor critical power metrics directly at the rack.
How is this PDU mounted in a rack?
This PDU is designed for vertical 0U rack mounting, meaning it installs vertically in standard 19-inch server racks without consuming any rack units of space. The compact 2.2-inch width allows it to fit alongside equipment while providing power distribution throughout the rack height.
What are the input and output voltage specifications?
The PDU accepts 230V AC three-phase input and delivers 208V AC output voltage. It operates at 60Hz frequency with 50A input current, making it suitable for standard North American three-phase power distribution in data center environments.
What is included in the package with this PDU?
The package contains the G6 42-Outlets PDU unit along with all necessary mounting hardware for secure installation in server racks. The PDU comes ready for deployment with its 10-foot power cord attached for immediate use in data center environments.
What power capacity is listed for this UPS?
The listed power specification is 17.30 kW, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 230 V AC, which helps position the unit for the right load level and installation role.