Panduit P36E34M-BU1A SmartZone G5 Intelligent Monitored 36-Outlet PDU - 8. 6 kVA - 415V AC Input - 30x C13 & 6x C19 Outlets - NEMA L21-30P - 0U
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This monitored PDU operates with three-phase power distribution, accepting 415V AC input through a NEMA L21-30P connector and delivering 208V AC output across all outlets. The 30A input current supports the full 8.6 kVA capacity, making it suitable for demanding server environments.
Network connectivity via RJ-45 enables remote monitoring of power consumption, outlet status, and environmental conditions. The vertical mounting orientation and 0U rack height allow installation in standard 19-inch racks without consuming valuable equipment space.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The SmartZone G5 PDU combines robust power distribution with intelligent management features. The three-phase design ensures balanced power delivery, while the monitored capabilities enable data center operators to optimize energy usage and identify potential issues before they impact operations.
These strengths make the product easier to deploy and manage in real environments, especially where reliability, usability, and day-to-day operational continuity matter. Notable benefits include Intelligent Power Monitoring, High-Density Outlet Configuration.
Intelligent Power Monitoring
Network-enabled monitoring provides real-time visibility into power usage, outlet status, and environmental metrics for proactive infrastructure management.
- Remote monitoring capabilities
- Real-time power consumption data
- Outlet-level status reporting
High-Density Outlet Configuration
Thirty C13 and six C19 outlets support mixed IT equipment deployments in space-constrained rack environments.
- 36 total outlets
- Mixed C13/C19 configuration
- Optimized for server racks
Deployment / Use Cases
This PDU is designed for environments where reliable power distribution and monitoring are essential. The 0U vertical mounting makes it particularly valuable in fully populated server racks where horizontal PDU space is unavailable.
The combination of C13 and C19 outlets supports mixed equipment deployments, from 1U servers to larger networking devices and storage arrays. The three-phase power distribution ensures efficient operation in facilities with three-phase electrical infrastructure.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Data Center Server Racks
Ideal for high-density server deployments requiring multiple power connections and remote monitoring capabilities in enterprise data centers.
Network Equipment Closets
Suitable for telecommunications and networking environments where space optimization and power monitoring are critical for uptime.
Physical Profile
The PDU features a vertical mounting design with 0U rack height, measuring 68.90 inches in length to fit standard rack depths. With a compact 2.05-inch width and 2.10-inch depth, it installs neatly in rack side channels without interfering with equipment mounting.
The vertical orientation and RoHS-compliant construction ensure reliable operation in data center environments while meeting environmental standards. The unit's dimensions allow installation in both shallow and deep rack configurations commonly found in server rooms and data centers.
- Width
- 2.05" (51.99 mm)
- Depth
- 2.10" (53.34 mm)
- Height
- 0U
- Length
- 68.90" (1750.01 mm)
Highlights
- 36 total outlets: 30 IEC 60320 C13 and 6 IEC 60320 C19
- 8.6 kVA power capacity with three-phase distribution
- 415V AC input voltage with 208V AC output
- Intelligent monitored PDU with network connectivity
- 0U vertical rack-mountable design
- NEMA L21-30P input connector
- 30A input current rating
- RoHS compliant construction
- Three-year limited warranty
- Vertical mounting orientation for space optimization
Specifications
| Specifications | |
|---|---|
| Manufacturer | PANDUIT CORP |
| Manufacturer Part Number | P36E34M-BU1A |
| Brand Name | Panduit |
| Product Line | SmartZone |
| Product Series | MS |
| Product Name | SmartZone G5 Intelligent 36-Outlets PDU |
| Packaged Quantity | 1 |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Monitored |
| Phase | Three Phase |
| Plug/Connector Type | NEMA L21-30P |
| Receptacle Type | IEC 60320 C13,IEC 60320 C19 |
| Receptacle Detail | 30 x IEC 60320 C13,6 x IEC 60320 C19 |
| Power Description | |
| Input Voltage | 415 V AC |
| Output Voltage | 208 V AC |
| Power Rating (VA) | 8.60 VA |
| Power Rating (Watt) | 8.60 kW |
| Input Current | 30 A |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Rack Height | 0U |
| Width | 2.05" (51.99 mm) |
| Depth | 2.10" (53.34 mm) |
| Length | 68.90" (1750.01 mm) |
| Miscellaneous | |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 3 Year |
FAQ
What is the power capacity of this PDU?
This Panduit SmartZone G5 PDU has a power capacity of 8.6 kVA (8,600 VA) with a corresponding wattage rating of 8.6 kW. It operates with three-phase power distribution, accepting 415V AC input and delivering 208V AC output across all outlets to support high-density server and networking equipment.
How many outlets does this PDU have and what types?
The PDU features 36 total outlets: 30 IEC 60320 C13 outlets and 6 IEC 60320 C19 outlets. This mixed configuration accommodates various IT equipment types, from standard servers and networking devices to equipment requiring higher-current C19 connections in data center environments.
What type of input connector does this PDU use?
This PDU uses a NEMA L21-30P input connector, which is a three-phase, 30-amp locking plug commonly used in commercial and data center electrical installations. This connector type ensures secure power connection and is designed for three-phase 415V AC input systems.
How is this PDU mounted in a rack?
The PDU is designed for 0U vertical mounting in standard 19-inch equipment racks. It mounts vertically in rack side channels without consuming horizontal rack space (U space), making it ideal for fully populated server racks where horizontal PDU mounting space is limited or unavailable.
What monitoring capabilities does this intelligent PDU offer?
As a monitored PDU, it provides network connectivity via RJ-45 for remote monitoring of power consumption, outlet status, and environmental conditions. This enables data center operators to track energy usage, identify potential issues, and manage power distribution proactively through network management systems.
What are the physical dimensions of this PDU?
The PDU measures 68.90 inches in length to fit standard rack depths, with a width of 2.05 inches and depth of 2.10 inches. These compact dimensions allow installation in rack side channels while the vertical orientation optimizes space utilization in server racks and network cabinets.
What power capacity is listed for this UPS?
The listed power specification is 8.60 VA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 415 V AC, which helps position the unit for the right load level and installation role.