Altronix Dual Input Access Power Controller 8 PTC Protected Outputs Board - LED Indicator - Access Control (ACMS8CB)

Have questions?

  • Canadian distributor

    Proud Canadian business since 2007

  • IT experts available

    Consulting & Technicial services

  • Pre-configuration services

    From VoiP phone to Clustered servers

  • Delivering across Canada

    Shipping UPS Fedex & Purolator

Write a Review
MSRP: $310.00
$310.00
$162.31
You save $147.69
SKU: ACMS8CB
UPC: 782239956425
Availability: Stock In Canada - Ship UPS & Purolator
Weight: 1.25 LBS
Shipping: Calculated at Checkout
Adding to cart… The item has been added

    Marketing Information:

    Altronix ACMS8CB is UL listed sub-assemblies designed to be used in Altronix wall and rack mount enclosures. Input power to ACMS8CB is to be derived from eFlow series power supplies. Dual input design allows power to be steered from two (2) independent low voltage 5 to 24 VDC power sources into eight (8) independently controlled PTC protected outputs. Outputs are activated by an open collector sink, normally open (NO), normally closed (NC) dry trigger input, or wet input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. ACMS8CB will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs. The spade connectors allow you to daisy chain power to multiple ACMS8CB module. This feature allows you to distribute the power over more outputs for larger systems.

    Device Supported: Rack Mount Enclosure,Wall Mount Enclosure,Electric Strike,Access Control Device,Magnetic Lock,Magnetic Door Holder

    Features: LED Indicator

    Height: 1.25" (31.75 mm)

    Width: 4.13" (104.78 mm)

    Length: 7.65" (194.31 mm)

    Weight (Approximate): 317.5 g

    Package Contents:

    • Dual Input Access Power Controller 8 PTC Protected Outputs Board
    • Mounting Hardware

    Additional Information:

    • Input
      • Two (2) independent low voltage inputs.
      • 1) Input: 12 or 24VDC from eFlow series Altronix Power supply.
      • 2) Input: 12 or 24 VDC from eFlow series Altronix power supply or either 5 or 12 VDC from VR6 Regulator.
      • Voltage Range
      • 16A total input.
      • Main PTC Rating 9A.
      • Current Consumption:
      • 0.6A @ 12V, 0.3A @ 24V with all relays energized.
    • Trigger Inputs
      • Eight (8) individually controlled trigger inputs:
      • a) Normally open (NO) inputs.
      • b) Normally closed (NC) inputs.
      • c) Open collector sink inputs.
      • d) Wet Input (5VDC - 24VDC) with 10K resistor.
      • e) Any combination of the above.
    • Outputs
    • Fuse protected outputs rated @ 2.5A per output, non power-limited. Total output 20A max.
    • Do not exceed the individual power supply ratings.
    • Eight (8) selectable 5VDC - 24VDC independently controlled outputs or eight (8) indepently controlled Form "C" relay outputs:
    • a) Fail-Safe and/or Fail-Secure power outputs.
    • b) Form "C" Relays. 28VAC or VDC @ 2.5A Rated.
    • c) Auxiliary power outputs (unswitched).
    • d) Any combination of the above.
    • Any of the eight (8) fuse protected power outputs are selectable to follow power Input 1 or Input 2.
    • Individual outputs may be set to OFF position for servicing.
    • Output Ratings
    • PTCs are rated 2A each.
    • Total output current is determined by the power supply(ies), not to exceed a maximum of 10A for each input.
    • Fire Alarm Disconnect
    • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
      • Fire Alarm disconnect input options:
      • a) Normally open [NO] or normally closed [NC] dry contact input. Polarity reversal input from FACP signaling circuit.
    • FACP output relay [NC] contact or provides 10k resistance with [EOL JMP] intact.
    • LED Indicators
    • Red LEDs indicate outputs are triggered.
    • Blue LED indicates FACP disconnect is triggered.
      • Individual voltage LEDs
      • Green: 12VDC
      • Red: 24VDC.
    • Temperature
    • Operating 0ºC to 49ºC (32ºF to 120ºF).
    • Storage -20ºC to 70ºC (-4ºF to 158ºF).
    • Relative Humidity 93% +/-5%.
    • BTU/Hr. (approx.): 4 BTU/Hr.

    Application/Usage: Access Control

    Country of Origin: United States

    Environmentally Friendly: Yes

    Environmental Compliance: Restriction of Hazardous Substances (RoHS)

    Limited Warranty: Lifetime

[custom-highlights][/custom-highlights]

[custom-specifications]

Specifications
ManufacturerAltronix Corporation
Manufacturer Part NumberACMS8CB
Manufacturer Website Addresshttp://www.altronix.com
Brand NameAltronix
Product NameDual Input Access Power Controller 8 PTC Protected Outputs Board
Product TypeDual Input Access Power Controller Board
Technical Information
Device SupportedRack Mount Enclosure,Wall Mount Enclosure,Electric Strike,Access Control Device,Magnetic Lock,Magnetic Door Holder
FeaturesLED Indicator
Physical Characteristics
Height1.25" (31.75 mm)
Width4.13" (104.78 mm)
Length7.65" (194.31 mm)
Weight (Approximate)317.5 g
Miscellaneous
Package Contents
  • Dual Input Access Power Controller 8 PTC Protected Outputs Board
  • Mounting Hardware
Additional Information
  • Input
    • Two (2) independent low voltage inputs.
    • 1) Input: 12 or 24VDC from eFlow series Altronix Power supply.
    • 2) Input: 12 or 24 VDC from eFlow series Altronix power supply or either 5 or 12 VDC from VR6 Regulator.
    • Voltage Range
    • 16A total input.
    • Main PTC Rating 9A.
    • Current Consumption:
    • 0.6A @ 12V, 0.3A @ 24V with all relays energized.
  • Trigger Inputs
    • Eight (8) individually controlled trigger inputs:
    • a) Normally open (NO) inputs.
    • b) Normally closed (NC) inputs.
    • c) Open collector sink inputs.
    • d) Wet Input (5VDC - 24VDC) with 10K resistor.
    • e) Any combination of the above.
  • Outputs
  • Fuse protected outputs rated @ 2.5A per output, non power-limited. Total output 20A max.
  • Do not exceed the individual power supply ratings.
  • Eight (8) selectable 5VDC - 24VDC independently controlled outputs or eight (8) indepently controlled Form "C" relay outputs:
  • a) Fail-Safe and/or Fail-Secure power outputs.
  • b) Form "C" Relays. 28VAC or VDC @ 2.5A Rated.
  • c) Auxiliary power outputs (unswitched).
  • d) Any combination of the above.
  • Any of the eight (8) fuse protected power outputs are selectable to follow power Input 1 or Input 2.
  • Individual outputs may be set to OFF position for servicing.
  • Output Ratings
  • PTCs are rated 2A each.
  • Total output current is determined by the power supply(ies), not to exceed a maximum of 10A for each input.
  • Fire Alarm Disconnect
  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
    • Fire Alarm disconnect input options:
    • a) Normally open [NO] or normally closed [NC] dry contact input. Polarity reversal input from FACP signaling circuit.
  • FACP output relay [NC] contact or provides 10k resistance with [EOL JMP] intact.
  • LED Indicators
  • Red LEDs indicate outputs are triggered.
  • Blue LED indicates FACP disconnect is triggered.
    • Individual voltage LEDs
    • Green: 12VDC
    • Red: 24VDC.
  • Temperature
  • Operating 0ºC to 49ºC (32ºF to 120ºF).
  • Storage -20ºC to 70ºC (-4ºF to 158ºF).
  • Relative Humidity 93% +/-5%.
  • BTU/Hr. (approx.): 4 BTU/Hr.
Application/UsageAccess Control
Country of OriginUnited States
Environmentally FriendlyYes
Environmental ComplianceRestriction of Hazardous Substances (RoHS)
Warranty
Limited WarrantyLifetime

[/custom-specifications]

[custom-options]

 

[/custom-options]

Warranty Infomartion

Lifetime