    Marketing Information: Double-Conversion UPS Protects Equipment Against Damage, Downtime and Data Loss
    This on-line double-conversion UPS system maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC. Constant on-line operation isolates sensitive equipment from power problems on the AC line. The SmartOnline® SU3000XLCD provides the highest level of power protection and battery backup for education, healthcare, military, government and other mission-critical IT applications where space is limited, but premium power reliability is essential.

    Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages
    The field-replaceable, hot-swappable VRLA battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Zero transfer time between on-line and battery modes maintains continuous operation of connected equipment without interruption or rebooting. Extra runtime is available by connecting up to four optional extended battery modules (BP96V, sold separately).

    Optional Network Management Card Allows Remote Access 24/7
    The WEBCARDLXE network interface (sold separately) enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options.

    NEMA Outlets Protect Your Connected Components
    One L5-30R and four 5-20R outlets provide connected equipment with pure sine wave AC output and allow you to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. The 5-20R outlets are grouped into two load banks that let you shed non-critical loads to extend runtime for critical loads.

    Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform Better
    This UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform better and last longer.

    Clear LCD Interface Keeps You Informed at a Glance
    The menu-driven front-panel LCD provides detailed alarms and notifications to help diagnose any issues. It provides system status, event logs, battery and power module status, usage analytics, serial number, firmware update info and more. Audible alarms can be disabled through the front menu when the UPS goes to battery power.

    Advanced Communications Ports Allow for Automatic Saves and Shutdowns
    RS-232 and USB ports connect to a device for a variety of communication options (cables are included). A dry-contact relay port can be programmed through the LCD to provide reliable communications to automation and industrial components. The RPO/ROO port permits emergency shutdown or remote restart of all connected equipment.

    More from the Manufacturer

    Plug/Connector Type: NEMA 5-15P

    Receptacle Type: NEMA 5-20R,NEMA L5-30R

    Receptacle Detail: 4 x NEMA 5-20R,1 x NEMA L5-30R

    Overload Protection: Yes

    Transfer Time: 0 ns

    Phase: Single Phase

    Application/Usage: IT Equipment,Mission Critical Equipment,Government,Healthcare,Education,Military

    Load Capacity (VA): 3 kVA

    Load Capacity (Watt): 2.70 kW

    Input Voltage: 120 V AC

    Output Voltage: 100 V AC,110 V AC,120 V AC

    Output Frequency: 60 Hz

    Waveform Type: Pure Sine Wave

    Surge Energy Rating: 190 J

    Input Power Factor: 0.99

    Output Power Factor: 0.9

    Display: LCD

    Network Management: SNMP

    Alarm: Remote Shutdown,UPS StartUp,Power Failure,Overload,UPS Fault,Low Battery

    Status Indicators: Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options

    Serial Port: Yes

    USB: Yes

    DC System Voltage: 96 V DC

    Battery Characteristics: Valve-regulated

    Battery Chemistry: Lead Acid

    Backup/Run Time (Full Load): 5.70 Minute

    Backup/Run Time (Half Load): 16.70 Minute

    Hot Swappable: Yes

    Typical Battery Recharge Time: 3 Hour

    Replaceable Battery: Yes

    Maximum Operating Elevation: 9842.52 ft (3000000 mm)

    Storage Temperature: 32°F (0°C) - 104°F (40°C)

    Minimum Operating Temperature: 32°F (0°C)

    Maximum Operating Temperature: 104°F (40°C)

    Sound Emission: 52 dB

    Height: 13.63" (346.20 mm)

    Width: 8.43" (214.12 mm)

    Depth: 16.23" (412.24 mm)

    Form Factor: Tower

    Weight (Approximate): 33.40 kg

    Package Contents:

  • SmartOnline SU3000XLCD 3000VA Tower UPS
  • USB cable
  • DB9 cable
  • Quick Start Guide
  • Software Included: PowerAlert Software

    Country of Origin: China

    Environmentally Friendly: Yes

    Environmental Compliance: Registration, Evaluation, Authorization and Restriction of Chemicals (REACH),Restriction of Hazardous Substances (RoHS)

    Limited Warranty: 2 Year

[custom-highlights]
  • Updated design for 2023
  • Protects equipment against blackouts, brownouts, transient surges and line noise
  • Keeps equipment running during outages to allow time for file saves and safe shutdown
  • Zero transfer time between on-line and battery modes for uninterrupted operation
  • Optional WEBCARDLXE network card enables full remote access and control
  • Menu-driven LCD keeps you up to date with status info and other vital analytics
[/custom-highlights]

[custom-specifications]

Specifications
ManufacturerTripp Lite by Eaton
Manufacturer Part NumberSU3000XLCD
Manufacturer Website Addresshttps://tripplite.eaton.com/
Brand NameTripp Lite series
Product LineSmartOnline
Product ModelSU3000XLCD
Product NameSmartOnline SU3000XLCD 3000VA Tower UPS
Product TypeDouble Conversion Online UPS
Technical Information
Plug/Connector TypeNEMA 5-15P
Receptacle TypeNEMA 5-20R,NEMA L5-30R
Receptacle Detail4 x NEMA 5-20R,1 x NEMA L5-30R
Overload ProtectionYes
Transfer Time0 ns
PhaseSingle Phase
Application/UsageIT Equipment,Mission Critical Equipment,Government,Healthcare,Education,Military
Power Description
Load Capacity (VA)3 kVA
Load Capacity (Watt)2.70 kW
Input Voltage120 V AC
Output Voltage100 V AC,110 V AC,120 V AC
Output Frequency60 Hz
Waveform TypePure Sine Wave
Surge Energy Rating190 J
Input Power Factor0.99
Output Power Factor0.9
Display & Graphics
DisplayLCD
Management
Network ManagementSNMP
AlarmRemote Shutdown,UPS StartUp,Power Failure,Overload,UPS Fault,Low Battery
Controls/Indicators
Status IndicatorsFront panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options
Interfaces/Ports
Serial PortYes
USBYes
Battery Information
DC System Voltage96 V DC
Battery CharacteristicsValve-regulated
Battery ChemistryLead Acid
Backup/Run Time (Full Load)5.70 Minute
Backup/Run Time (Half Load)16.70 Minute
Hot SwappableYes
Typical Battery Recharge Time3 Hour
Replaceable BatteryYes
Environmental Conditions
Maximum Operating Elevation9842.52 ft (3000000 mm)
Storage Temperature32°F (0°C) - 104°F (40°C)
Minimum Operating Temperature32°F (0°C)
Maximum Operating Temperature104°F (40°C)
Sound Emission52 dB
Physical Characteristics
Height13.63" (346.20 mm)
Width8.43" (214.12 mm)
Depth16.23" (412.24 mm)
Form FactorTower
Weight (Approximate)33.40 kg
Miscellaneous
Package Contents
  • SmartOnline SU3000XLCD 3000VA Tower UPS
  • USB cable
  • DB9 cable
  • Quick Start Guide
  • Software IncludedPowerAlert Software
    Country of OriginChina
    Environmentally FriendlyYes
    Environmental ComplianceRegistration, Evaluation, Authorization and Restriction of Chemicals (REACH),Restriction of Hazardous Substances (RoHS)
    Warranty
    Limited Warranty2 Year