Raritan PX3-5464V 20-Outlet PDU - 5 kVA - 230V AC - NEMA L6-30P - 16x C13 & 4x C19 - 0U Rack-Mountable
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This power distribution unit operates at 230 volts AC with a 5 kVA power rating, translating to substantial capacity for demanding IT loads. The 30-amp input current ensures efficient power delivery without voltage drop across connected devices. The unit maintains consistent power distribution across all 20 outlets, supporting both standard and high-power equipment configurations.
The outlet configuration includes 16 IEC 60320 C13 receptacles for typical server and network gear, plus 4 IEC 60320 C19 receptacles for higher-power devices requiring up to 16A per outlet. This balanced mix allows for flexible equipment deployment while maximizing rack power utilization.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The PX3-5464V delivers efficient power distribution with zero rack space consumption, making it ideal for maximizing equipment density in constrained environments. The 5 kVA capacity supports substantial IT loads while maintaining stable power delivery across all connected devices.
Space-Efficient Design
The 0U vertical mounting requires no horizontal rack space, allowing for maximum equipment density while maintaining proper power distribution throughout the rack.
- Zero rack units consumed
- Vertical installation
- Preserves horizontal space for equipment
Balanced Outlet Configuration
With 16 C13 and 4 C19 outlets, the PDU accommodates both standard and high-power equipment, providing flexibility for diverse IT deployments.
- 16 standard C13 outlets
- 4 high-power C19 outlets
- Supports mixed equipment types
Robust Power Delivery
The 5 kVA capacity and 30A input current ensure stable power distribution even under heavy loads, reducing the risk of voltage fluctuations affecting sensitive equipment.
- 5 kVA total capacity
- 30A input current
- 230V AC operation
Deployment / Use Cases
This PDU is specifically designed for rack-mounted IT environments where space optimization and reliable power distribution are critical. The 0U vertical mounting makes it ideal for high-density server racks, network cabinets, and storage arrays where every rack unit matters.
Common deployment scenarios include data center server racks supporting multiple 1U and 2U servers, network equipment cabinets with switches and routers, and storage arrays with both controllers and drive enclosures. The outlet mix accommodates everything from standard servers and switches to higher-power storage controllers and networking gear.
Data Center Server Racks
Provides power distribution for multiple servers in high-density configurations while consuming zero horizontal rack space.
- High-density server deployments
- Zero space consumption
- Stable power for critical servers
Network Equipment Cabinets
Distributes power to switches, routers, and other networking gear with the outlet mix to support various equipment types.
- Mixed networking equipment
- Reliable power for network infrastructure
- Space-efficient installation
Highlights
- 5 kVA power capacity for substantial IT loads
- 20 total outlets with 16 C13 and 4 C19 configuration
- 230V AC input voltage with 30A current rating
- 0U rack-mountable design saves horizontal space
- NEMA L6-30P input connector for high-power applications
- Vertical mounting in standard 19-inch racks
- Manufactured by Raritan under Legrand Group
- Ideal for data centers and server room deployments
Specifications
| Specifications | |
|---|---|
| Manufacturer | Legrand Group |
| Manufacturer Part Number | PX3-5464V |
| Brand Name | Raritan |
| Product Name | 20-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| Plug/Connector Type | NEMA L6-30P |
| Receptacle Type | IEC 60320 C13,IEC 60320 C19 |
| Receptacle Detail | 16 x IEC 60320 C13,4 x IEC 60320 C19 |
| Power Description | |
| Input Voltage | 230 V AC |
| Power Rating (VA) | 5 kVA |
| Input Current | 30 A |
| Physical Characteristics | |
| Mount Type | Rack-mountable |
| Rack Height | 0U |
| Miscellaneous | |
| Country of Origin | Taiwan |
User Manual
FAQ
What is the power capacity of this PDU?
The Raritan PX3-5464V has a 5 kVA power capacity, providing substantial power distribution for multiple servers, networking equipment, and storage devices in rack-mounted environments. This capacity supports demanding IT loads while maintaining stable voltage delivery across all connected equipment.
How many outlets does this PDU have and what types?
This power distribution unit features 20 total outlets: 16 IEC 60320 C13 receptacles for standard equipment and 4 IEC 60320 C19 receptacles for higher-power devices. This configuration accommodates a mix of server, networking, and storage equipment with different power requirements in the same rack.
What input voltage and current does this PDU require?
The PDU operates at 230 volts AC with a 30-amp input current. This high-current capacity ensures efficient power delivery without voltage drop, making it suitable for environments with substantial power requirements and multiple connected devices drawing significant current.
How does the 0U rack mounting work?
The 0U designation means this PDU mounts vertically in standard 19-inch racks without consuming any horizontal rack units. This space-efficient installation preserves all horizontal space for servers, switches, and other equipment while still providing full power distribution capabilities throughout the rack.
What type of input connector does this PDU use?
This unit features a NEMA L6-30P input connector, which is designed for 30-amp, 230-volt applications. This connector type is commonly used in data center and server room environments where higher power capacity is required for multiple pieces of equipment in a single rack.
Where is this PDU typically deployed?
The PX3-5464V is designed for rack-mounted IT environments including data centers, server rooms, network cabinets, and colocation facilities. Its space-efficient 0U design makes it particularly valuable in high-density deployments where maximizing equipment per rack is a priority.
What power capacity is listed for this UPS?
The listed power specification is 5 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 230 V AC, which helps position the unit for the right load level and installation role.