Raritan PX3-5870V-C5 Monitored 30-Outlet PDU - 5 kVA - 230 V AC - NEMA L6-30P - 24x C13 - 6x C19 - Vertical 0U Rack
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This PDU features a NEMA L6-30P plug connector designed for 230 V AC power sources, with an output voltage of 208 V AC to match typical rack equipment requirements. The 30 A input current supports the full 5 kVA capacity, ensuring reliable power delivery under load.
Network connectivity via RJ-45 enables remote monitoring and management through standard IP networks, allowing administrators to track power metrics and control outlets without physical access. The unit is TAA compliant for government procurement and meets RoHS environmental standards.
This section brings together practical product details such as PDU Type, Plug/Connector Type, Receptacle Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The vertical 0U mounting orientation eliminates the need for horizontal rack space, making it ideal for full-height rack deployments where every U of space is critical. Remote outlet switching adds operational flexibility, allowing power cycling of individual devices for maintenance or troubleshooting.
These strengths make the product easier to deploy and manage in real environments, especially where reliability, usability, and day-to-day operational continuity matter. Notable benefits include Active Power Monitoring, High-Density Outlet Layout.
Active Power Monitoring
Real-time metering of voltage, current, and power consumption helps optimize energy usage and identify potential circuit issues before they cause downtime.
High-Density Outlet Layout
With 24 C13 and 6 C19 outlets, this PDU accommodates a mix of server, switch, and storage power cables in a single vertical unit.
Deployment / Use Cases
This PDU is suited for environments where power visibility and control are priorities, such as colocation facilities, enterprise data centers, and managed service provider racks. The monitored functionality supports capacity planning and helps maintain power quality across critical infrastructure.
The vertical form factor and 0U rack height make it compatible with standard 19-inch racks without consuming horizontal space, allowing for clean cable management along the rack side.
This section brings together practical product details such as PDU Type, Plug/Connector Type, Receptacle Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Data Center Racks
Deploy in server racks to distribute power to blade servers, network switches, and storage arrays while monitoring energy consumption across the rack.
Network Closets
Install in telecom or network closets to power PoE switches, routers, and security appliances with circuit protection and remote management capabilities.
Physical Profile
Designed for vertical mounting on rack sides, the PDU measures 70.10 inches in height, 2.10 inches in width, and 2.60 inches in depth. This slim profile fits seamlessly into rack channels without interfering with equipment installation or airflow. The all-metal construction ensures durability in rack environments, and the vertical orientation facilitates organized power cable routing.
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 0U, 2.10" (53.34 mm), 2.60" (66.04 mm). This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 2.10" (53.34 mm)
- Depth
- 2.60" (66.04 mm)
- Height
- 0U
Highlights
- 5 kVA power capacity with 230 V AC input and 208 V AC output
- 30 total outlets: 24 IEC C13 and 6 IEC C19 for versatile device connectivity
- Vertical 0U rack mounting saves horizontal space in standard 19-inch racks
- Active metering enables real-time monitoring of voltage, current, and power
- Remote outlet switching via RJ-45 network interface for management
- Overload and overcurrent protection safeguards connected equipment
- TAA compliant for government and educational procurement
- RoHS compliant and backed by a 2-year limited warranty
Specifications
| Specifications | |
|---|---|
| Manufacturer | Legrand Group |
| Manufacturer Part Number | PX3-5870V-C5 |
| Brand Name | Raritan |
| Product Series | PX3 |
| Product Name | PX3 30-Outlet PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Monitored |
| Plug/Connector Type | NEMA L6-30P (2P3W) |
| Receptacle Type | IEC 60320 C13,IEC 60320 C19 |
| Receptacle Detail | 24 x IEC 60320 C13,6 x IEC 60320 C19 |
| Protection Type | Overload Protection,Overcurrent Protection |
| Power Description | |
| Input Voltage | 230 V AC |
| Output Voltage | 208 V AC |
| Power Rating (VA) | 5 kVA |
| Input Current | 30 A |
| Management | |
| Remote Outlet Switching | Yes |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Rack Height | 0U |
| Height | 70.10" (1780.54 mm) |
| Width | 2.10" (53.34 mm) |
| Depth | 2.60" (66.04 mm) |
| Miscellaneous | |
| Country of Origin | Taiwan |
| TAA Compliant | Yes |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What is the power capacity of this PDU?
The Raritan PX3-5870V-C5 delivers 5 kVA of power capacity with a 230 V AC input voltage and 208 V AC output. This capacity supports high-density rack deployments by providing sufficient power for multiple servers, switches, and storage devices simultaneously.
How many outlets does this PDU have and what types?
This PDU features 30 total outlets: 24 IEC 60320 C13 outlets and 6 IEC 60320 C19 outlets. The C13 outlets are standard for most IT equipment, while the C19 outlets support higher-power devices like servers and UPS units, offering flexibility for mixed environments.
What does 'monitored PDU' mean?
A monitored PDU provides active metering of power metrics such as voltage, current, and power consumption. This allows IT staff to monitor energy usage in real time, optimize power distribution, and receive alerts for potential issues, enhancing overall power management and circuit protection.
How is this PDU mounted in a rack?
This PDU is designed for vertical mounting with a 0U rack height, meaning it mounts on the side of a standard 19-inch rack without consuming horizontal rack units. The vertical orientation saves space and facilitates organized cable management along the rack side.
What input plug type does this PDU use?
The PDU uses a NEMA L6-30P (2P3W) plug connector, which is designed for 230 V AC power sources. This plug type is common in commercial and data center environments for delivering high-power capacity to rack equipment.
Can I remotely control outlets on this PDU?
Yes, this PDU supports remote outlet switching via its RJ-45 network interface. This allows administrators to power cycle individual outlets remotely for maintenance or troubleshooting, improving operational efficiency without physical access to the rack.
What power capacity is listed for this UPS?
The listed power specification is 5 kVA, which helps position the unit for the right load level and installation role.
How many outlets are available?
The product includes Yes, which helps buyers understand how many connected devices it can support in its intended deployment.