Raritan PX3-4039V-E2 32-Outlet PDU - Metered-by-Outlet - 5 kVA - NEMA L14-30P Input - 20x C13 - 6x C19 - 6x NEMA 5-20R Outlets - Rack-Mountable
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This single-phase PDU operates at 208 V AC with an input range of 190-208 V AC and delivers output voltage from 100-208 V AC. The 30 A input current supports the full 5 kVA capacity, while 60 Hz frequency ensures compatibility with North American power systems. Overload protection and branch circuit safeguards prevent damage from electrical faults.
Network connectivity via RJ-45 enables remote monitoring capabilities, though remote outlet switching is not supported. The metered-by-outlet functionality allows administrators to track power consumption per device, facilitating capacity planning and energy management. SecureLock receptacles prevent accidental disconnection of critical equipment.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The PX3-4039V-E2 provides granular power monitoring that helps optimize energy usage and identify inefficient devices. Per-outlet metering delivers actionable data for capacity management and cost allocation in multi-tenant or departmental environments.
Mixed Outlet Compatibility
With 20 IEC C13, 6 IEC C19, and 6 NEMA 5-20R receptacles, this PDU supports diverse equipment from servers and switches to monitors and peripherals without requiring adapters.
- C13 for standard IT equipment
- C19 for high-power devices
- NEMA 5-20R for office electronics
Rack-Optimized Design
The vertical form factor occupies minimal rack space while providing extensive outlet capacity. The 70.1-inch height maximizes outlet density in full-height racks.
- 2.1" width fits standard racks
- Black powder coat finish
- Secure mounting hardware
Visual Load Monitoring
The integrated LCD display shows real-time power metrics without requiring network connectivity, providing immediate visibility during hands-on maintenance.
- Local load verification
- No software required
- Instant status checking
Deployment / Use Cases
This PDU is ideal for data center cabinets requiring detailed power monitoring for billing or capacity management. The metered-by-outlet capability makes it suitable for colocation facilities, cloud providers, or enterprises that need to track power usage by customer, department, or specific equipment.
Server rooms with mixed equipment benefit from the outlet variety, allowing direct connection of servers, storage arrays, networking gear, and support equipment. The 5 kVA capacity supports moderate-density racks with multiple 1U-2U servers and associated infrastructure.
Data Center Power Monitoring
Deploy in racks where per-device power tracking is required for capacity planning, chargeback systems, or efficiency optimization initiatives.
Mixed-Equipment Server Cabinets
Use in environments with diverse power requirements, combining servers (C13/C19) with monitors, KVM switches, or other peripherals (NEMA 5-20R).
Physical Profile
The vertical rack-mountable design measures 70.10" height × 2.10" width × 2.80" depth (1780.54 × 53.34 × 71.12 mm), optimizing outlet density in standard 19-inch racks. At 7.60 kg, the unit provides substantial construction without excessive weight. The 9.8-foot power cord offers flexibility in rack placement relative to power sources.
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 70.10" (1780.54 mm), 2.10" (53.34 mm), 2.80" (71.12 mm), 7.60 kg. This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 2.10" (53.34 mm)
- Depth
- 2.80" (71.12 mm)
- Height
- 70.10" (1780.54 mm)
- Weight
- 7.60 kg
- Length
- 9.8 ft
Highlights
- 32 total outlets with mixed IEC and NEMA configurations
- Metered-by-outlet monitoring for individual device power tracking
- 5 kVA capacity with 208 V AC input and 30 A current
- NEMA L14-30P (3P4W) plug for three-phase power connection
- Rack-mountable vertical design with black powder coat finish
- LCD display for local power monitoring without network
- Overload protection and branch circuit safeguards
- Network RJ-45 port for remote monitoring capabilities
- SecureLock receptacles prevent accidental disconnection
- 2-year limited warranty with RoHS environmental compliance
Specifications
| Specifications | |
|---|---|
| Manufacturer | Legrand Group |
| Manufacturer Part Number | PX3-4039V-E2 |
| Brand Name | Raritan |
| Product Series | PX3 |
| Product Model | PX3-4039V-E2 |
| Product Name | PX3-4039V-E2 32-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Metered-by-Outlet |
| Phase | Single Phase |
| Plug/Connector Type | NEMA L14-30P (3P4W) |
| Receptacle Type | IEC 60320 C13,IEC 60320 C19,NEMA 5-20R |
| Receptacle Detail | 20 x IEC 60320 C13,6 x IEC 60320 C19,6 x NEMA 5-20R |
| Protection Type | Overload Protection,Branch Circuit |
| Locking Receptacles | SecureLock |
| Features | LCD Display,Onboard Display |
| Load Capacity (VA) | 5 W |
| Power Description | |
| Input Voltage | 208 V AC |
| Input Voltage Range | 190 V AC - 208 V AC |
| Output Voltage | 208 V AC |
| Output Voltage Range | 100 V AC - 208 V AC |
| Power Rating (VA) | 5 kVA |
| Input Current | 30 A |
| Input Frequency | 60 Hz |
| Management | |
| Remote Outlet Switching | No |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Product Color | Black Powder Coat |
| Mount Type | Rack-mountable |
| Cord Length | 9.8 ft |
| Height | 70.10" (1780.54 mm) |
| Width | 2.10" (53.34 mm) |
| Depth | 2.80" (71.12 mm) |
| Weight (Approximate) | 7.60 kg |
| Environmental Conditions | |
| Maximum Operating Temperature | 140°F (60°C) |
| Maximum Operating Humidity | 85% |
| Miscellaneous | |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What does 'metered-by-outlet' mean on this PDU?
Metered-by-outlet means this PDU can monitor and display power consumption individually for each of its 32 outlets. This allows you to see exactly how much power specific devices are drawing, enabling precise capacity management, identifying inefficient equipment, and facilitating accurate power billing in multi-tenant environments.
What types of equipment can I connect to the different outlet types?
The 20 IEC C13 outlets are standard for servers, switches, and most IT equipment. The 6 IEC C19 outlets support higher-power devices like blade servers or UPS systems. The 6 NEMA 5-20R outlets accommodate monitors, printers, or other office electronics with standard North American plugs. This mix eliminates the need for adapters in racks with diverse equipment.
What power input does this PDU require?
This PDU uses a NEMA L14-30P plug that connects to 208 V AC three-phase power sources. It operates with an input voltage range of 190-208 V AC at 60 Hz frequency, drawing up to 30 A current to deliver its full 5 kVA capacity. Ensure your facility has compatible three-phase power available.
Can I remotely control individual outlets on this PDU?
No, this PDU does not support remote outlet switching. The RJ-45 network port enables remote monitoring of power metrics, but you cannot remotely turn outlets on or off. For remote control capabilities, you would need a switched PDU model instead of this metered-by-outlet version.
How is this PDU mounted in a rack?
This is a vertical rack-mountable PDU designed for installation in standard 19-inch racks. With dimensions of 70.10" height × 2.10" width × 2.80" depth, it occupies minimal horizontal space while providing extensive vertical outlet placement. The unit includes appropriate mounting hardware for secure installation in server cabinets.
What protection features does this PDU include?
The PDU provides overload protection to prevent damage from excessive current draw and branch circuit protection for added safety. SecureLock receptacles ensure power cords remain securely connected, preventing accidental disconnections that could disrupt critical equipment. These features help maintain uptime in server environments.
What power capacity is listed for this UPS?
The listed power specification is 5 W, which helps position the unit for the right load level and installation role.
How many outlets are available?
The product includes No, which helps buyers understand how many connected devices it can support in its intended deployment.