Sidebar Sidebar Sidebar

Shipping included*

Raritan PX3-5901U-V2 Managed PDU - 17. 3 kVA - 415 V - 42x C13 & 6x C19 Outlets - NEMA L22-30P - 3-Phase - Remote Switching

SKU: PX3-5901U-V2
(No reviews) Write a Review
MSRP: $4,942.51
$4,942.51
$4,553.99
Save: $388.52 (7.86%)
Warranty Information: 2 Year
Condition: New
Width: 8.89 (cm)
Height: 1.23 (cm)
Depth: 6.60 (cm)

Ask for ETA! 🗨️

Logo cards
B2B Pricing

Business volume discounts

IT Experts

Technical guidance

IT Configuration

Preparation & staging

Canada Stock

QC · ON · AB · BC

Product Features

Description

Product Overview

The Raritan PX3-5901U-V2 is a managed power distribution unit designed for high-density data center and server room environments. It delivers 17.3 kVA of three-phase power at 415 V, supporting demanding IT infrastructure with reliable, monitored power distribution.

This PDU features 42 IEC 60320 C13 outlets and 6 IEC 60320 C19 outlets, accommodating a mix of standard and high-power equipment. The NEMA L22-30P plug ensures compatibility with three-phase power sources, while built-in overload protection safeguards connected devices.

This section brings together practical product details such as Phase, Plug/Connector Type, Receptacle Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.

In practical terms, this overview should help a buyer understand what the product is, the type of environment it suits, and the core reasons it may be chosen over a more generic alternative. That context is especially useful for business purchasing, where fit, consistency, and ease of use usually matter as much as individual specifications.

Power
17.30 kVA
Power Capacity
Outlets: Yes415 V
Power Capacity & Electrical
Power Rating17.30 kVA
Input Voltage415 V
Input Current30 A
Outlet Configuration
C13 Outlets42 x IEC 60320 C13
C19 Outlets6 x IEC 60320 C19
Plug TypeNEMA L22-30P (4P5W)
Management & Monitoring
Remote Outlet SwitchingYes
Network InterfaceRJ-45
Environmental SensorsDifferential Pressure, Temperature, Water, Air Flow, Humidity, Contact Closure
Physical & Warranty
Dimensions70.10" H x 3.50" W x 2.60" D
PhaseThree Phase
Warranty2 Year Limited

Technical Overview

Engineered for three-phase power systems, the PX3-5901U-V2 operates at 415 V with a 30 A input current, delivering 17.30 kVA of capacity. The output matches the input voltage at 415 V AC, ensuring stable power distribution across all outlets.

Network connectivity via RJ-45 enables remote management and monitoring, while integrated environmental sensors track differential pressure, temperature, water, air flow, humidity, and contact closure events. This comprehensive monitoring supports proactive infrastructure management.

This section brings together practical product details such as Phase, Plug/Connector Type, Receptacle Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.

A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.

Power Capacity17.30 kVA
Input Voltage415 V
Input Current30 A
Outlet Count48 Total
Three-Phase PowerRemote ManagementEnvironmental MonitoringOverload Protection

Key Product Advantages

These strengths make the product easier to deploy and manage in real environments, especially where reliability, usability, and day-to-day operational continuity matter. Notable benefits include High-Density Outlet Configuration, Advanced Remote Management, Robust Protection Features.

High-Density Outlet Configuration

With 42 C13 and 6 C19 outlets, this PDU supports a large number of servers, switches, and storage devices in a single unit, optimizing rack space and reducing cable clutter.

Advanced Remote Management

Remote outlet switching allows individual outlet control for power cycling or scheduled shutdowns, while environmental sensors provide real-time monitoring of rack conditions.

Robust Protection Features

Overload protection prevents circuit overloading, and the three-phase design with NEMA L22-30P connection ensures reliable power delivery for critical equipment.

Deployment / Use Cases

The PX3-5901U-V2 is ideal for data centers, server rooms, and network closets where high-power density and remote management are essential. Its 17.3 kVA capacity and 48 outlets make it suitable for racks filled with servers, storage arrays, and networking gear.

Use this PDU in environments requiring precise power monitoring and control, such as colocation facilities, enterprise data centers, or broadcast studios. The environmental sensors add value for facilities monitoring temperature, humidity, and water detection near critical infrastructure.

This section brings together practical product details such as Phase, Plug/Connector Type, Receptacle Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.

Ports NEMA L22-30P (4P5W)

Physical Profile

Designed for vertical mounting in standard 19-inch racks, the PDU measures 70.10 inches in height, 3.50 inches in width, and 2.60 inches in depth. Its slim profile maximizes usable rack space while providing full-length power distribution.

The compact depth allows installation in shallow racks or tight spaces, and the vertical orientation simplifies cable management for organized power distribution across multiple equipment tiers.

Dimensions
Width
3.50" (88.90 mm)
Depth
2.60" (66.04 mm)
Height
70.10" (1780.54 mm)
[custom-highlights]

Highlights

  • 17.30 kVA three-phase power capacity at 415 V
  • 42 IEC 60320 C13 outlets and 6 IEC 60320 C19 outlets
  • NEMA L22-30P (4P5W) plug for three-phase connections
  • Remote outlet switching via network management
  • Environmental sensors for temperature, humidity, water, and air flow
  • Overload protection for connected equipment safety
  • RJ-45 network interface for remote monitoring
  • 2-year limited warranty for reliable performance
[/custom-highlights][custom-specifications]

Specifications

Specifications
ManufacturerLegrand Group
Manufacturer Part NumberPX3-5901U-V2
Brand NameRaritan
Product SeriesPX3
Product ModelPX3-5901U-V2
Product NamePX3-5901U-V2 (42) IEC320 C13, (6) IEC320 C19 PDU
Product TypePDU
Technical Information
PhaseThree Phase
Plug/Connector TypeNEMA L22-30P (4P5W)
Receptacle TypeIEC 60320 C13,IEC 60320 C19
Receptacle Detail42 x IEC 60320 C13,6 x IEC 60320 C19
Protection TypeOverload Protection
Environmental SensorsDifferential Pressure,Temperature,Water,Air Flow,Humidity,Contact Closure
Power Description
Input Voltage415 V
Output Voltage415 V AC
Power Rating (VA)17.30 kVA
Input Current30 A
Management
Remote Outlet SwitchingYes
Interfaces/Ports
Network (RJ-45)Yes
Physical Characteristics
Height70.10" (1780.54 mm)
Width3.50" (88.90 mm)
Depth2.60" (66.04 mm)
Warranty
Limited Warranty2 Year
[/custom-specifications][custom-user-manual]

User Manual

This section contains official documentation provided by the manufacturer, including product manuals, brochures, and supplementary materials.
[/custom-user-manual][custom-faq]

FAQ

What is the power capacity of this PDU?

The Raritan PX3-5901U-V2 delivers 17.30 kVA of power capacity, operating at 415 V with a 30 A input current. This three-phase configuration supports high-density server and networking equipment in data center environments.

How many outlets does this PDU have and what types?

This PDU features 48 total outlets: 42 IEC 60320 C13 outlets for standard equipment and 6 IEC 60320 C19 outlets for high-power devices. This mix accommodates servers, switches, storage, and other rack-mounted gear.

What type of power plug does this PDU use?

The PDU uses a NEMA L22-30P (4P5W) plug, designed for three-phase power connections. This plug type is common in data centers and commercial environments with three-phase electrical infrastructure.

Can I control individual outlets remotely?

Yes, the PDU supports remote outlet switching via its RJ-45 network interface. This allows administrators to power cycle specific outlets, schedule shutdowns, or manage power distribution without physical access to the rack.

What environmental monitoring features are included?

Integrated sensors monitor differential pressure, temperature, water, air flow, humidity, and contact closure events. These sensors help track rack conditions, detect leaks, and ensure optimal operating environments for connected equipment.

What are the physical dimensions of this PDU?

The PDU measures 70.10 inches in height, 3.50 inches in width, and 2.60 inches in depth. Its vertical design fits standard 19-inch racks, providing full-length power distribution while minimizing footprint.

What power capacity is listed for this UPS?

The listed power specification is 17.30 kVA, which helps position the unit for the right load level and installation role.

How many outlets are available?

The product includes Yes, which helps buyers understand how many connected devices it can support in its intended deployment.

[/custom-faq]
Volume Discounts
Qty Price Available
Match Price Request

Found a lower price? Send us the link and we will do our best to match or beat it.

Request received. We will reply within 24 hours.
Fleet Network
Wholesale & B2B
Partner with Us

Looking to buy in bulk? We offer competitive pricing, dedicated support, and custom solutions for businesses of all sizes.

Volume Discounts

Tiered pricing structure designed to maximize your margins as you grow.

Dedicated Account Manager

Direct access to a specialist who understands your business needs.

Fast & Reliable Shipping

Priority processing and discounted shipping rates for bulk orders.

Request a Quote
Thank you!
Your request has been sent successfully.
Raritan PX3-5901U-V2 Managed PDU - 17. 3 kVA - 415 V - 42x C13 & 6x C19 Outlets - NEMA L22-30P - 3-Phase - Remote Switching
MSRP: $4,942.51
$4,942.51
$4,553.99
Save: $388.52 (7.86%)
Out of stock