Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
APC by Schneider Electric GVSBPSU20K60H Galaxy VS Bypass Panel - Wall-Mountable White Panel for 3-Phase 20-60kW UPS Systems
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This bypass panel serves as a specialized electrical component within a UPS power protection system, providing a manual or automatic transfer path that routes utility power directly to the load when the UPS requires isolation. The panel incorporates safety-rated switching mechanisms and clear labeling to ensure proper operation during maintenance events.
Built to Schneider Electric's industrial standards, the panel features durable materials and precise engineering for long-term reliability in demanding environments. The design prioritizes electrical safety and operational clarity, with all connections and controls accessible for qualified personnel.
This section brings together practical product details such as Product Color, Form Factor, Height, Compatibility, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
The Galaxy VS Bypass Panel delivers essential functionality for maintaining UPS systems without compromising power continuity to critical loads. Its dedicated design eliminates the need for makeshift bypass solutions, reducing risk and ensuring compliance with electrical safety standards.
Maintenance Safety
Enables safe isolation of UPS systems for servicing, testing, or replacement while keeping connected equipment powered through direct utility feed.
- Reduces downtime during maintenance
- Minimizes risk to personnel and equipment
- Provides clear operational status indicators
System Compatibility
Specifically engineered for APC Galaxy VS UPS systems with 3-phase connections in the 20-60kW power range, ensuring proper electrical ratings and physical integration.
- Matches UPS electrical specifications
- Simplifies installation and wiring
- Maintains system warranty compliance
Installation Flexibility
Wall-mountable design with compact dimensions allows installation in various locations near the UPS system, optimizing space utilization in equipment rooms.
- Saves floor space
- Facilitates service access
- Integrates with existing rack or wall layouts
Deployment / Use Cases
This bypass panel is essential for any facility running APC Galaxy VS UPS systems where maintenance must occur without power interruption to critical loads. It serves as a permanent part of the power protection infrastructure, ready for use whenever UPS servicing is required.
Typical deployments include data centers hosting servers and network equipment, manufacturing facilities with process control systems, healthcare environments with medical equipment, and financial institutions with trading floors or data processing centers. Any application where even brief power interruption during UPS maintenance could cause operational disruption or data loss benefits from this integrated bypass solution.
Data Center Maintenance
Allows UPS firmware updates, battery replacement, or component repairs while servers and networking gear remain powered, preventing service interruptions during maintenance windows.
Industrial Process Continuity
Enables UPS servicing in manufacturing or process control environments where equipment shutdowns could disrupt production lines or compromise product quality.
Physical Profile
The panel features a clean white finish suitable for technical environments, with dimensions optimized for wall mounting near compatible UPS systems. The 25 kg weight indicates substantial construction with robust internal components, while the 8.66" depth provides a relatively slim profile that minimizes protrusion from the wall surface.
- Width
- 21.65" (550 mm)
- Depth
- 8.66" (220 mm)
- Height
- 23.62" (600 mm)
- Weight
- 25 kg
Highlights
- Compatible with APC Galaxy VS UPS systems (3-phase 20-60kW)
- Wall-mountable white panel with compact footprint
- Enables safe UPS maintenance without load interruption
- Dimensions: 23.62"H × 21.65"W × 8.66"D (600×550×220 mm)
- Weight: 25 kg for stable installation
- Designed for data center and industrial applications
- Provides manual/automatic transfer capability
- Integrates with existing power infrastructure
Specifications
| Specifications | |
|---|---|
| Manufacturer | Schneider Electric SA |
| Manufacturer Part Number | GVSBPSU20K60H |
| Brand Name | Schneider Electric |
| Product Name | Galaxy VS Bypass Panel |
| Product Type | Bypass Panel |
| Physical Characteristics | |
| Product Color | White |
| Form Factor | Wall-mountable |
| Height | 23.62" (600 mm) |
| Width | 21.65" (550 mm) |
| Depth | 8.66" (220 mm) |
| Weight (Approximate) | 25 kg |
| Miscellaneous | |
| Compatibility | APC Galaxy VS UPS Systems With 3-Phase Connection 20-60kW |
FAQ
What UPS systems is this bypass panel compatible with?
This bypass panel is specifically designed for APC Galaxy VS UPS systems with 3-phase electrical connections in the 20-60kW power range. It matches the electrical specifications and physical interface requirements of these UPS models to ensure safe and proper operation during maintenance bypass procedures.
How does this panel facilitate UPS maintenance?
The bypass panel provides a controlled electrical path that allows utility power to feed directly to connected equipment while the UPS is isolated for servicing. This enables technicians to safely perform firmware updates, battery replacements, component repairs, or system testing without interrupting power to critical loads that depend on continuous operation.
What are the physical dimensions and mounting options?
The panel measures 23.62 inches in height, 21.65 inches in width, and 8.66 inches in depth (600×550×220 mm), with an approximate weight of 25 kg. It is designed for wall mounting, which saves floor space and allows flexible installation near the compatible UPS system in equipment rooms or data centers.
What applications typically use this bypass panel?
This panel is deployed in environments where UPS maintenance must occur without power interruption, including data centers with servers and network equipment, manufacturing facilities with process control systems, healthcare settings with medical devices, and financial institutions with critical computing infrastructure. Any application requiring continuous power during UPS servicing benefits from this integrated solution.
What safety features does this bypass panel provide?
The panel incorporates safety-rated switching mechanisms, clear operational status indicators, and proper labeling to ensure safe use by qualified personnel. It eliminates the need for makeshift bypass solutions, reducing electrical risk during maintenance procedures while maintaining compliance with relevant electrical safety standards for industrial power equipment.
Does this panel require professional installation?
Yes, installation should be performed by qualified electrical personnel familiar with UPS systems and local electrical codes. The panel interfaces with 3-phase power systems in the 20-60kW range, requiring proper wiring, grounding, and integration with the existing UPS and electrical distribution infrastructure to ensure safe and reliable operation.