Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Server Technology C2WG24VT-2CBA1MC1 PRO2 Switched PDU - 24 Outlets - 18x C13 - 6x C19 - NEMA L6-30P - 230V AC - 5 kW - Rack-Mountable
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This switched PDU operates with 230V AC input voltage and delivers 208V AC output, handling up to 30A input current at 60Hz frequency. The NEMA L6-30P plug connector provides secure three-phase power connection, while the P-Lock compatible receptacles ensure power cords remain securely connected in vibration-prone environments.
The management subsystem supports HTTP/HTTPS with TLSv1.2 encryption, SSHv2, Telnet, SNMPv2c and v3 with GET, SET, and Traps functionality, IPv4 and IPv6 networking, LDAPv3/LDAPS for directory services, TACACS+ and RADIUS for authentication, plus FTP/SFTP, RS-232 serial, DHCP, and SMTP protocols for comprehensive integration.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The PRO2 PDU delivers enterprise-grade power distribution with intelligent monitoring and control features that optimize data center operations. Its comprehensive sensing capabilities provide visibility into power consumption at multiple levels, enabling proactive capacity planning and preventing overload situations.
Advanced Power Sensing
PIPS® (Per Inlet Power Sensing) and POPS® (Per Outlet Power Sensing) monitor current, voltage, power, apparent power, crest factor, power factor, and energy consumption at both inlet and individual outlet levels.
- Real-time load monitoring
- Phase-level current display
- Energy consumption tracking
Network Resilience
Hot-swap network card capability ensures network access continuity during power events, with backup power provided by linked units in multi-PDU configurations.
- Redundant network paths
- Star multi-linking support
- Primary expansion backup
Environmental Monitoring
Supports two external 10-foot temperature/humidity probes per unit, with SNMP-based alerts and email notifications for environmental condition changes.
- Dual probe support
- Proactive alerting
- Remote monitoring
Deployment / Use Cases
This switched PDU is designed for deployment in data centers, server rooms, and network closets where reliable power distribution with monitoring and control capabilities is essential. The rack-mountable form factor and compact 1.75-inch width make it ideal for high-density cabinet installations where space optimization is critical.
The unit supports IT equipment power distribution in environments requiring individual outlet control for server reboots, power sequencing, or energy management. The branch circuit protection with UL 489 rated magnetic-hydraulic circuit breakers or UL 248 fuses ensures compliance with UL and IEC 62368-1 safety requirements for branch circuit protection in commercial installations.
Data Center Power Management
Enables precise power control and monitoring for server racks, with remote outlet switching for equipment reboots and power cycling without physical access to the data center floor.
High-Density Cabinet Deployment
The slim 1.75-inch width and 64-inch height allow installation in standard 19-inch racks alongside other equipment, maximizing usable space in constrained cabinet environments.
Physical Profile
The PRO2 PDU features a rack-optimized design measuring 64 inches in height, 1.75 inches in width, and 3.50 inches in depth, engineered for vertical mounting in standard 19-inch server racks and cabinets. The unit includes standard button mounts for secure installation, with provisions for custom mounting brackets to accommodate specific rack configurations or mounting requirements.
- Width
- 1.75" (44.45 mm)
- Depth
- 3.50" (88.90 mm)
- Height
- 64" (1625.60 mm)
What's in the Box
The package includes the PRO2 24-Outlets PDU unit with standard button mounts for rack installation.
Package contents include PRO2 24-Outlets PDU Standard Button Mounts, PRO2 24-Outlets PDU. These included items support setup, installation, and immediate deployment without needing to source the core bundled accessories separately.
Highlights
- 24-outlet configuration with 18 C13 and 6 C19 receptacles for versatile equipment connectivity
- Switched PDU with remote outlet control for individual outlet power cycling
- 5 kW power capacity with 230V AC input and 208V AC output
- Comprehensive network management via HTTP/HTTPS, SSH, Telnet, SNMP, and multiple protocols
- Per-inlet and per-outlet power sensing (PIPS® and POPS®) for detailed power monitoring
- Branch circuit protection with UL 489 circuit breakers or UL 248 fuses
- Rack-mountable design with 64" height and 1.75" width for high-density installations
- Temperature and humidity monitoring with external probe support
- Hot-swap network card capability for network resilience during power events
- Two-year limited warranty from Server Technology
Specifications
| Specifications | |
|---|---|
| Manufacturer | Legrand Group |
| Manufacturer Part Number | C2WG24VT-2CBA1MC1 |
| Brand Name | Server Technology |
| Product Series | PRO2 |
| Product Name | PRO2 24-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Switched |
| Phase | Three Phase |
| Plug/Connector Type | NEMA L6-30P |
| Receptacle Type | IEC 60320 C13,IEC 60320 C19 |
| Receptacle Detail | 18 x IEC 60320 C13,6 x IEC 60320 C19 |
| Protection Type | Branch Circuit,Circuit Protection,Circuit Breaker,Fuse |
| Locking Receptacles | P-Lock |
| Features | LED Display |
| Power Description | |
| Input Voltage | 230 V AC |
| Output Voltage | 208 V AC |
| Power Rating (Watt) | 5 kW |
| Input Current | 30 A |
| Input Frequency | 60 Hz |
| Management | |
| Management | HTTP/HTTPS TLSv1.2 SSHv2 Telnet SNMPv2c SNMPv3 (GET, SET, Traps) IPv4 IPv6 LDAPv3/LDAPS TACACS+ RADIUS FTP/SFTP RS-232 serial DHCP SMTP |
| Remote Outlet Switching | Yes |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Mount Type | Rack-mountable,Cabinet-mountable |
| Height | 64" (1625.60 mm) |
| Width | 1.75" (44.45 mm) |
| Depth | 3.50" (88.90 mm) |
| Environmental Conditions | |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Operating Temperature | 140°F (60°C) |
| Minimum Storage Temperature | -40°F (-40°C) |
| Maximum Storage Temperature | 185°F (85°C) |
| Minimum Operating Humidity | 8% |
| Maximum Operating Humidity | 90% |
| Miscellaneous | |
| Package Contents | PRO2 24-Outlets PDU Standard Button Mounts |
| Application/Usage | IT Equipment,Server Rack/Cabinet |
| Warranty | |
| Limited Warranty | 2 Year |
FAQ
What is the power capacity of this Server Technology PDU?
This PRO2 PDU has a 5 kW power rating, with 230V AC input voltage and 208V AC output voltage. It handles 30A input current at 60Hz frequency, making it suitable for powering multiple servers and networking equipment in data center environments.
How many outlets does this PDU have and what types are they?
The PDU features 24 total outlets: 18 IEC 60320 C13 receptacles and 6 IEC 60320 C19 receptacles. This configuration supports a mix of standard server power cords (C13) and higher-power equipment requiring C19 connections, providing flexibility for diverse IT equipment deployments.
What management capabilities does this switched PDU offer?
The PDU supports comprehensive network management through HTTP/HTTPS with TLSv1.2, SSHv2, Telnet, SNMPv2c and v3, IPv4/IPv6, LDAPv3/LDAPS, TACACS+, RADIUS, FTP/SFTP, RS-232 serial, DHCP, and SMTP. Remote outlet switching allows individual outlet control for equipment reboots or power management.
Is this PDU rack-mountable and what are its dimensions?
Yes, this PDU is designed for rack or cabinet mounting with dimensions of 64 inches height, 1.75 inches width, and 3.50 inches depth. The slim 1.75-inch width allows installation in high-density server racks alongside other equipment, and it includes standard button mounts for secure attachment.
What type of power monitoring features are included?
The PDU includes PIPS® (Per Inlet Power Sensing) and POPS® (Per Outlet Power Sensing) that monitor current, voltage, power, apparent power, crest factor, power factor, and energy consumption. It also features branch current monitoring with alerts for high usage and an auto-flip LED display showing current per phase for load balancing.
What safety certifications and protection does this PDU have?
This PDU meets UL and IEC 62368-1 requirements for branch circuit protection through UL 489 rated magnetic-hydraulic circuit breakers or UL 248 fuses. It has been tested for reliable operation in 60°C data center environments and features high-retention P-Lock compatible receptacles for secure power cord connections.
What power capacity is listed for this UPS?
The listed power specification is 5 kW, which helps position the unit for the right load level and installation role.
How many outlets are available?
The product includes Yes, which helps buyers understand how many connected devices it can support in its intended deployment.