Server Technology C2W36TE-2CAF2M99 PRO2 Switched PDU - 36 Outlets - 18 x C13 & 18 x CX - 5 kW - 230V AC - NEMA L6-30P - Rack-Mountable
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This PRO2 PDU operates on a three-phase electrical system with a 30A input current at 60 Hz frequency. The load capacity and power rating are both 5 kW, providing consistent power distribution across all 36 outlets. Input and output voltages are 230V AC and 208V AC respectively, suitable for many server and networking devices in commercial IT setups.
Network management is comprehensive, supporting HTTP/HTTPS with TLSv1.2, SSHv2, Telnet, SNMPv2c and v3 (including GET, SET, and Traps), IPv4 and IPv6, LDAPv3/LDAPS, TACACS+, RADIUS, and FTP/SFTP protocols. This allows integration into existing network management systems for monitoring and control. The unit also features an LED display for real-time current per phase viewing, aiding in load balancing and overload prevention.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
The PRO2 PDU offers advanced monitoring and control features that enhance reliability and operational efficiency in data centers. Its switched outlet capability allows administrators to remotely power cycle equipment, reducing downtime and enabling efficient power management. The inclusion of CX hybrid receptacles provides flexibility for current and future power cord standards, accommodating both C14 and C20 plugs without adapter needs.
Advanced Monitoring
Per-Inlet Power Sensing (PIPS) meets ANSI C12.1 for billing-grade accuracy, monitoring voltage, active power, apparent power, power factor, and energy. Branch current monitoring tracks usage at each breaker branch, sending SNMP alerts and emails to prevent circuit trips.
- Billing-grade accuracy
- Real-time branch monitoring
- SNMP and email alerts
Environmental Sensors
Primary and link units each support two external 10-foot temperature/humidity probes. This enables SNMP-based alerts and email notifications for environmental conditions, helping maintain optimal operating environments for sensitive IT equipment.
- External T/H probes
- SNMP alerts
- Email notifications
Deployment / Use Cases
This PDU is designed for deployment in server racks and IT equipment cabinets within data centers, server rooms, and network closets. Its 36-outlet configuration and 5 kW capacity make it suitable for high-density environments where multiple servers, switches, and storage devices require reliable, managed power distribution.
Common use cases include enterprise data centers needing remote power management for server reboots, colocation facilities requiring detailed power monitoring for billing or capacity planning, and IT departments managing server cabinets with mixed equipment using both C13 and C20 power cords. The rack-mountable design with button mounts ensures secure installation in standard 19-inch cabinet rails.
Physical Profile
The PDU features a compact vertical design measuring 70 inches in height, 2.20 inches in width, and 2.50 inches in depth (1778 mm x 55.88 mm x 63.50 mm). This slim profile maximizes space efficiency in server racks while providing full front-access to all 36 outlets. Mounting options include standard button mounts for secure rack installation, with provisions for custom mounting brackets if needed.
- Width
- 2.20" (55.88 mm)
- Depth
- 2.50" (63.50 mm)
- Height
- 70" (1778 mm)
What's in the Box
The package includes the PRO2 36-Outlets PDU unit along with standard button mounts for rack installation.
Package contents include PRO2 36-Outlets PDU Standard Button Mounts, PRO2 36-Outlets PDU. These included items support setup, installation, and immediate deployment without needing to source the core bundled accessories separately.
Highlights
- 36 total outlets: 18 IEC 60320 C13 and 18 CX hybrid receptacles
- 5 kW power rating with 230V AC input and 208V AC output
- Switched PDU with remote outlet control for individual or group power cycling
- Comprehensive network management via HTTP/HTTPS, SSH, Telnet, SNMP, and more
- Branch circuit protection with fuses and UL489-rated circuit breakers
- Per-Inlet Power Sensing (PIPS) with billing-grade accuracy
- Temperature and humidity monitoring with external probe support
- Auto-flip LED display for three-phase current monitoring
- Rack-mountable design with button mounts for 19-inch cabinets
- 2-year limited warranty
Specifications
| Specifications | |
|---|---|
| Manufacturer | Legrand Group |
| Manufacturer Part Number | C2W36TE-2CAF2M99 |
| Brand Name | Server Technology |
| Product Series | PRO2 |
| Product Name | PRO2 36-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Switched |
| Phase | Three Phase |
| Plug/Connector Type | NEMA L6-30P |
| Receptacle Type | IEC 60320 C13,CX |
| Receptacle Detail | 18 x IEC 60320 C13,18 x CX |
| Protection Type | Branch Circuit,Circuit Protection,Fuse |
| Features | LED Display |
| Load Capacity (Watt) | 5 kW |
| Power Description | |
| Input Voltage | 230 V AC |
| Output Voltage | 208 V AC |
| Power Rating (Watt) | 5 kW |
| Input Current | 30 A |
| Input Frequency | 60 Hz |
| Management | |
| Management | HTTP/HTTPS TLSv1.2 SSHv2 Telnet SNMPv2c v3 (GET, SET, Traps) IPv4 and IPv6 LDAPv3/LDAPS TACACS+ RADIUS FTP/SFTP |
| Remote Outlet Switching | Yes |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Mount Type | Rack-mountable,Cabinet-mountable,Button Mount |
| Height | 70" (1778 mm) |
| Width | 2.20" (55.88 mm) |
| Depth | 2.50" (63.50 mm) |
| Environmental Conditions | |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Operating Temperature | 140°F (60°C) |
| Minimum Storage Temperature | -40°F (-40°C) |
| Maximum Storage Temperature | 185°F (85°C) |
| Minimum Operating Humidity | 8% |
| Maximum Operating Humidity | 90% |
| Miscellaneous | |
| Package Contents | PRO2 36-Outlets PDU Standard Button Mounts |
| Application/Usage | IT Equipment,Server Rack/Cabinet |
| Warranty | |
| Limited Warranty | 2 Year |
FAQ
What is the power capacity of this Server Technology PDU?
This PRO2 PDU has a 5 kW power rating and load capacity. It operates with a three-phase 230V AC input that steps down to 208V AC output, supporting up to 30A input current at 60 Hz frequency for powering IT equipment in server racks and cabinets.
How many outlets does this PDU have and what types are they?
The unit provides 36 total outlets: 18 are standard IEC 60320 C13 receptacles and 18 are CX hybrid receptacles. The CX outlets are UL-tested hybrids that accommodate both C14 and C20 plugs, offering flexibility for current and future power cord standards without needing adapters.
What management capabilities does this switched PDU offer?
This switched PDU supports extensive network management protocols including HTTP/HTTPS with TLSv1.2, SSHv2, Telnet, SNMPv2c and v3, IPv4 and IPv6, LDAPv3/LDAPS, TACACS+, RADIUS, and FTP/SFTP. Remote outlet switching allows individual or group outlet power cycling for server reboots and power management.
What protection features are included in this power distribution unit?
The PDU includes branch circuit protection using UL489-rated magnetic-hydraulic circuit breakers or UL248 fuses, meeting UL and IEC 60950-1 requirements. It also features branch current monitoring that provides SNMP alerts and emails on high usage to prevent circuit trips, plus Per-Inlet Power Sensing for accurate power measurement.
How is this PDU mounted in a server rack?
The unit is designed for rack mounting with standard button mounts included in the package. It has a vertical profile measuring 70 inches tall by 2.20 inches wide by 2.50 inches deep, fitting standard 19-inch server cabinet rails. The design also supports cabinet mounting and includes provisions for custom mounting brackets if needed.
What environmental monitoring capabilities does this PDU support?
Primary and link units each support two external 10-foot temperature and humidity probes. This enables SNMP-based alerts and email notifications for environmental conditions, helping maintain optimal operating environments for sensitive IT equipment in data centers and server rooms.
What power capacity is listed for this UPS?
The listed power specification is 5 kW, which helps position the unit for the right load level and installation role.
How many outlets are available?
The product includes Yes, which helps buyers understand how many connected devices it can support in its intended deployment.