Server Technology C2S39TS-2CBA2S444 PRO2 Monitored Rack PDU - 39 Outlets - 27x C13 - 12x CX - 5 kW - 230V AC - NEMA L6-30P
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This monitored PDU provides detailed power metrics through its network management interface, enabling real-time monitoring of voltage, current, and load distribution across all three phases. The unit features comprehensive circuit protection including double-pole breakers and overload protection to safeguard connected equipment.
Network connectivity is established via an RJ-45 port that supports multiple management protocols including HTTP/HTTPS with TLS 1.2 encryption, SNMPv2c for integration with network monitoring systems, SSHv2 for secure command-line access, and Telnet for legacy compatibility. The management system also supports IPv4 and IPv6 addressing, LDAPv3/LDAPS for directory services integration, and TACACS+/RADIUS for authentication.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The PRO2 series monitored PDU delivers enterprise-grade power management with granular visibility into power consumption at the outlet level. Remote monitoring capabilities allow IT administrators to track power usage trends, identify potential overload conditions before they cause downtime, and optimize power distribution across the rack.
Comprehensive Protection
Features circuit protection with double-pole breakers and overload protection to prevent damage to connected equipment during power anomalies or excessive load conditions.
- Double-pole circuit protection
- Overload protection
- Three-phase monitoring
Advanced Management
Supports multiple management protocols including SNMP for integration with existing monitoring systems, SSH for secure administration, and HTTPS for encrypted web access.
- SNMPv2c integration
- SSHv2 secure access
- HTTPS with TLS 1.2
Deployment / Use Cases
This monitored PDU is engineered for data center environments where precise power management and equipment protection are critical. The three-phase design and 5 kW capacity make it suitable for high-density server racks, networking equipment cabinets, and storage arrays in enterprise data centers.
The unit's slim 1.75-inch width allows for efficient use of rack space while providing 39 outlets to power multiple servers, switches, and storage devices from a single power source. Network management capabilities enable integration with data center infrastructure management (DCIM) systems for centralized monitoring of power metrics across the facility.
Data Center Server Racks
Ideal for high-density server deployments where multiple servers, switches, and storage devices require reliable, monitored power distribution with overload protection.
Network Equipment Cabinets
Suitable for telecommunications and networking environments where equipment protection and power monitoring are essential for maintaining network availability.
Physical Profile
Designed for standard 19-inch rack mounting, this PDU features a slim profile that maximizes usable rack space. The unit measures 69 inches in height to provide full vertical coverage in standard server racks, with a depth of 2.25 inches that fits comfortably in most cabinet configurations. The compact 1.75-inch width ensures minimal interference with cable management systems while providing ample outlet spacing for power cord connections.
- Width
- 1.75" (44.45 mm)
- Depth
- 2.25" (57.15 mm)
- Height
- 69" (1752.60 mm)
What's in the Box
The package includes the PRO2 C2S39TS-2CBA2S444 39-outlet PDU along with necessary button mounts for secure rack installation.
Package contents include PRO2 C2S39TS-2CBA2S444 39-Outlets PDU Button Mounts, PRO2 C2S39TS-2CBA2S444 39-Outlets PDU. These included items support setup, installation, and immediate deployment without needing to source the core bundled accessories separately.
Highlights
- Monitored three-phase PDU with 5 kW power capacity
- 39 total outlets: 27 IEC C13 and 12 CX receptacles
- 230V AC input with NEMA L6-30P plug
- Network management via RJ-45 with multiple protocols
- Comprehensive circuit and overload protection
- Rack-mountable design with slim 1.75-inch width
- Real-time monitoring of voltage, current, and load
- 2-year limited warranty for reliable operation
Specifications
| Specifications | |
|---|---|
| Manufacturer | Legrand Group |
| Manufacturer Part Number | C2S39TS-2CBA2S444 |
| Brand Name | Server Technology |
| Product Series | PRO2 |
| Product Model | C2S39TS-2CBA2S444 |
| Product Name | PRO2 C2S39TS-2CBA2S444 39-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Monitored |
| Phase | Three Phase |
| Plug/Connector Type | NEMA L6-30P |
| Receptacle Type | IEC 60320 C13,CX |
| Receptacle Detail | 27 x IEC 60320 C13,12 x CX |
| Protection Type | Circuit Protection,Double Pole,Overload Protection |
| Power Description | |
| Input Voltage | 230 V AC |
| Power Rating (Watt) | 5 kW |
| Input Current | 30 A |
| Management | |
| Management | HTTP/HTTPS TLSv1.2 SSHv2 Telnet SNMPv2c IPv4 IPv6 LDAPv3/LDAPS TACACS+ RADIUS FTP/SFTP v3: GET SET Traps |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Mount Type | Rack-mountable,Cabinet-mountable |
| Height | 69" (1752.60 mm) |
| Width | 1.75" (44.45 mm) |
| Depth | 2.25" (57.15 mm) |
| Miscellaneous | |
| Package Contents | PRO2 C2S39TS-2CBA2S444 39-Outlets PDU Button Mounts |
| Warranty | |
| Limited Warranty | 2 Year |
FAQ
What type of power input does this PDU require?
This PDU requires a three-phase 230V AC power source with a NEMA L6-30P input plug. The unit is rated for 30A input current and delivers 5 kW of total power capacity, making it suitable for data center environments with three-phase power distribution.
How many outlets does this PDU have and what types are they?
The PDU features 39 total outlets consisting of 27 IEC 60320 C13 receptacles and 12 CX receptacles. This combination supports a wide range of server, networking, and storage equipment with standard power cords while providing flexibility for different device types in rack deployments.
What management capabilities does this monitored PDU offer?
This monitored PDU provides network management through an RJ-45 interface supporting multiple protocols including HTTP/HTTPS with TLS 1.2 encryption, SNMPv2c for integration with monitoring systems, SSHv2 for secure command-line access, and Telnet. It also supports IPv4 and IPv6 addressing, enabling remote monitoring of voltage, current, and load metrics across all three phases.
What protection features are included with this PDU?
The PDU includes comprehensive circuit protection with double-pole breakers and overload protection. These features help prevent damage to connected equipment during power anomalies or excessive load conditions, ensuring reliable operation of critical IT infrastructure in data center environments.
How is this PDU mounted in a rack?
This PDU is designed for standard 19-inch rack mounting and includes button mounts for secure installation. With dimensions of 69 inches high, 1.75 inches wide, and 2.25 inches deep, it provides full vertical coverage in server racks while maintaining a slim profile that maximizes usable space for equipment.
What warranty coverage does this Server Technology PDU include?
The PRO2 C2S39TS-2CBA2S444 PDU comes with a 2-year limited warranty. This coverage ensures reliable operation and protection against manufacturing defects, providing confidence for deployment in critical data center power distribution applications.