Server Technology C4W36RA-DQBD2FE1 PRO4 x 36-Outlet Switched PDU - 17. 3 kW - 230V AC Input - 12x C13 & 24x CX Outlets - Rack-Mountable
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This PDU integrates a multi-color LCD for local status display and supports comprehensive network management via HTTP/HTTPS, SNMPv2c/v3, SSHv2, Telnet, and IPv6. Environmental sensors monitor temperature, humidity, water, contact closure, air flow, and differential pressure, providing early warning for rack conditions.
The IEC 60309 3P+G 9Hr 60A input connector ensures secure high-current connection, while branch circuit protection and circuit breakers safeguard against overloads. RamLock locking outlets prevent accidental disconnections in vibration-prone environments.
This section brings together practical product details such as PDU Type, Plug/Connector Type, Receptacle Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The PRO4X PDU transforms basic power distribution into a managed infrastructure component. Administrators gain visibility into power consumption patterns, set thresholds for alerts, and respond to issues proactively through the network interface.
These strengths make the product easier to deploy and manage in real environments, especially where reliability, usability, and day-to-day operational continuity matter. Notable benefits include Intelligent Power Control, Comprehensive Monitoring.
Intelligent Power Control
Remote outlet switching allows power cycling of individual devices, reducing downtime and enabling scheduled maintenance without physical intervention.
- Load balancing via network management
- Digital current meter prevents overloads
Comprehensive Monitoring
Built-in sensors track environmental factors like temperature and humidity, while the LCD and network interfaces provide real-time power metrics and alerts.
- Multi-protocol support (SNMP, HTTP, SSH)
- Granular outlet-level power data
Deployment / Use Cases
Deploy this switched PDU in environments where power reliability and management are critical. The 36-outlet capacity supports fully populated racks, while the slim 2.2" width conserves valuable rack space.
Use cases extend to telecommunications cabinets, broadcast facilities, and laboratory setups where equipment must remain powered and monitored continuously. The environmental sensors add value for climate-sensitive installations.
This section brings together practical product details such as PDU Type, Plug/Connector Type, Receptacle Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
High-Density Data Centers
Ideal for server racks with multiple blade servers, storage arrays, and networking switches requiring numerous power connections and centralized management.
Remote Site Management
Enables IT teams to monitor and control power for equipment in colocation facilities or branch offices without on-site visits, reducing operational costs.
Physical Profile
Rack-mountable with a vertical form factor measuring 70" high, 2.20" wide, and 2.50" deep, this PDU fits standard 19" rack enclosures without protruding. The compact depth allows installation in shallow cabinets, while the height accommodates full-height rack deployment.
The durable construction and locking receptacles ensure reliable operation in vibration-prone environments. The multi-color LCD is positioned for easy viewing during maintenance.
- Width
- 2.20" (55.88 mm)
- Depth
- 2.50" (63.50 mm)
- Height
- 70" (1778 mm)
Highlights
- 36 total outlets: 12 IEC C13 and 24 CX receptacles
- 17.3 kW power rating with 230V AC input and 208V AC output
- Switched PDU with remote outlet control and monitoring
- Network management via HTTP/HTTPS, SNMP, SSH, Telnet, IPv4/IPv6
- Environmental sensors for temperature, humidity, water, air flow
- Multi-color LCD for local status display
- RamLock locking outlets prevent accidental disconnection
- Rack-mountable design: 70"H x 2.20"W x 2.50"D
- IEC 60309 3P+G 9Hr 60A input connector
- 2-year limited warranty
Specifications
| Specifications | |
|---|---|
| Manufacturer | Legrand Group |
| Manufacturer Part Number | C4W36RA-DQBD2FE1 |
| Brand Name | Server Technology |
| Product Series | PRO4X |
| Product Name | PRO4X 36-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Switched |
| Plug/Connector Type | IEC 60309 3P+G 9Hr 60A |
| Receptacle Type | IEC 60320 C13,CX |
| Receptacle Detail | 12 x IEC 60320 C13,24 x CX |
| Protection Type | Branch Circuit,Circuit Protection,Circuit Breaker |
| Locking Receptacles | RamLock Locking Outlet |
| Environmental Sensors | Temperature,Humidity,Water,Contact Closure,Air Flow,Differential Pressure |
| Features | Multi-color LCD |
| Power Description | |
| Input Voltage | 230 V AC |
| Output Voltage | 208 V AC |
| Power Rating (Watt) | 17.30 kW |
| Input Current | 60 A |
| Management | |
| Management | HTTP/HTTPS TLSv1.2 SSHv2 Telnet SNMPv2c v3 (GET, SET, Traps) IPv4 IPv6 LDAPv3/LDAPS TACACS+ RADIUS FTP/SFTP RS-232 |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Mount Type | Rack-mountable |
| Height | 70" (1778 mm) |
| Width | 2.20" (55.88 mm) |
| Depth | 2.50" (63.50 mm) |
| Warranty | |
| Limited Warranty | 2 Year |
FAQ
What is the total power capacity of this PDU?
This Server Technology PRO4X PDU has a power rating of 17.30 kW (17,300 watts). It accepts 230V AC input and delivers 208V AC output with a maximum input current of 60 amps, making it suitable for high-density rack deployments with multiple servers and networking equipment.
How many outlets does this PDU have and what types?
The PDU provides 36 total outlets: 12 are IEC 60320 C13 receptacles (common for server and network gear power cords) and 24 are CX receptacles. This mixed configuration supports a variety of equipment in a single rack, reducing the need for additional power strips or adapters.
What management features does this switched PDU offer?
It supports comprehensive network management including HTTP/HTTPS with TLSv1.2, SNMPv2c and v3 for monitoring and traps, SSHv2 and Telnet for secure command-line access, IPv4 and IPv6 networking, plus LDAPv3/LDAPS, TACACS+, and RADIUS for authentication. The multi-color LCD provides local status, and environmental sensors monitor rack conditions.
Is this PDU rack-mountable and what are its dimensions?
Yes, it is designed for rack mounting with dimensions of 70 inches (1778 mm) in height, 2.20 inches (55.88 mm) in width, and 2.50 inches (63.50 mm) in depth. This vertical form factor fits standard 19-inch rack enclosures and has a slim profile to conserve space.
What type of input connector does this PDU use?
It uses an IEC 60309 3P+G 9Hr 60A connector, which is a high-current, three-phase plus ground plug type rated for 60 amps. This industrial-grade connector ensures secure power delivery for the PDU's 17.3 kW capacity in data center environments.
What protection features are included?
The PDU includes branch circuit protection and circuit breakers to prevent overloads. It also has RamLock locking outlets that secure power cords in place, reducing the risk of accidental disconnections. Environmental sensors add protection by monitoring conditions like temperature and humidity.
What power capacity is listed for this UPS?
The listed power specification is 17.30 kW, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 230 V AC, which helps position the unit for the right load level and installation role.