Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Server Technology C4S36RA-DQBD2FE1 Pro4X Smart Monitored PDU - 36 Outlets - 12x IEC 60309 C13 - 24x CX - 230V AC - 17. 3 kW - Rack-Mountable
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This three-phase PDU features IEC 60309 3P+G input connectivity and delivers power through a combination of 12 IEC 60309 C13 outlets and 24 CX outlets, providing flexibility for various equipment configurations. The 60A input current capacity supports demanding power requirements in modern server environments.
Built with overcurrent protection, branch circuit protection, and fuse protection, the PDU safeguards connected equipment from electrical faults. The HDOT Cx RamLock locking receptacles ensure secure connections that won't accidentally disconnect, which is critical for maintaining uptime in production environments.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The Pro4X Smart PDU combines high power capacity with intelligent monitoring features that transform basic power distribution into a manageable infrastructure component. Unlike basic PDUs that simply distribute power, this monitored unit provides visibility into power consumption patterns and alerts administrators to potential issues before they impact operations.
Intelligent Power Monitoring
Real-time monitoring capabilities allow IT staff to track power usage at the outlet level, identify underutilized or overloaded circuits, and make data-driven decisions about power allocation.
- Prevents overloads before they occur
- Enables power usage optimization
- Provides actionable power consumption data
Secure Connection Design
HDOT Cx RamLock locking receptacles ensure power cords remain securely connected, eliminating accidental disconnections that can cause downtime in critical server environments.
- Prevents accidental disconnection
- Maintains uptime for critical systems
- Secure locking mechanism
Deployment / Use Cases
This PDU is ideally suited for data centers, server rooms, and network closets where reliable power distribution and monitoring are essential. The 36-outlet configuration supports dense server deployments, while the 17.3 kW capacity handles power requirements for modern high-density computing equipment.
The vertical rack-mount design makes it particularly valuable in space-constrained environments where horizontal PDUs would consume valuable rack space. The monitored capabilities provide the visibility needed for capacity planning, power budgeting, and identifying inefficient power usage patterns across the infrastructure.
Data Center Power Distribution
Deploy in server racks to distribute power to multiple servers, switches, and storage devices while monitoring consumption to prevent circuit overloads and optimize power allocation.
High-Density Server Environments
Support blade servers and high-density computing equipment with the 17.3 kW power capacity and 36-outlet configuration that accommodates multiple power supplies per device.
Physical Profile
Designed for vertical rack mounting, this PDU measures 70" (1778 mm) in height, 2.20" (55.88 mm) in width, and 3.07" (77.98 mm) in depth. The slim profile minimizes the space occupied in server racks while providing full-length access to all 36 outlets. The vertical orientation places outlets along the entire height of the rack, making them easily accessible for cable management and equipment servicing.
- Width
- 2.20" (55.88 mm)
- Depth
- 3.07" (77.98 mm)
- Height
- 70" (1778 mm)
Highlights
- 36 total outlets with 12 IEC 60309 C13 and 24 CX receptacles
- 17.3 kW power capacity with 230V AC input and 60A current
- Monitored PDU type with real-time power consumption tracking
- Three-phase power distribution with IEC 60309 3P+G input
- Vertical rack-mountable design for space-efficient installation
- Overcurrent, branch circuit, and fuse protection for equipment safety
- HDOT Cx RamLock locking receptacles prevent accidental disconnection
- 2-year limited warranty for reliable long-term operation
Specifications
| Specifications | |
|---|---|
| Manufacturer | Legrand Group |
| Manufacturer Part Number | C4S36RA-DQBD2FE1 |
| Brand Name | Server Technology |
| Product Series | Pro4X Smart |
| Product Name | Pro4X Smart 36-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Monitored |
| Phase | Three Phase |
| Plug/Connector Type | IEC 60309 3P+G |
| Receptacle Type | IEC 60320 C13,CX |
| Receptacle Detail | 12 x IEC 60309 C13,24 x CX |
| Protection Type | Overcurrent Protection,Branch Circuit,Fuse,Double Pole |
| Locking Receptacles | HDOT Cx RamLock |
| Power Description | |
| Input Voltage | 230 V AC |
| Power Rating (Watt) | 17.30 kW |
| Input Current | 60 A |
| Physical Characteristics | |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Form Factor | Rack |
| Height | 70" (1778 mm) |
| Width | 2.20" (55.88 mm) |
| Depth | 3.07" (77.98 mm) |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What is the power capacity of this Server Technology PDU?
This Pro4X Smart PDU delivers 17.30 kW of power capacity with a 230V AC input voltage and 60A input current. This substantial capacity supports demanding server and networking equipment in data center environments, allowing for high-density deployments without overloading the power distribution infrastructure.
How many outlets does this PDU have and what types are they?
The PDU features 36 total outlets consisting of 12 IEC 60309 C13 outlets and 24 CX outlets. This mixed configuration provides flexibility for connecting various types of equipment, from servers and switches to storage devices and other rack-mounted hardware that use different power connector types.
What does 'monitored' mean for this PDU?
As a monitored PDU, this unit provides real-time power monitoring capabilities that track power consumption at the outlet level. This allows IT administrators to identify potential overloads before they occur, optimize power allocation, and receive alerts about abnormal power usage patterns that could indicate equipment issues or inefficient configurations.
How is this PDU mounted in a server rack?
This PDU is designed for vertical rack mounting with a form factor specifically for rack installation. It mounts vertically along the side or rear of server racks, measuring 70" in height to fit standard rack heights. The vertical orientation maximizes outlet accessibility while minimizing the space occupied in the rack compared to horizontal PDUs.
What protection features does this PDU include?
The PDU incorporates multiple protection mechanisms including overcurrent protection, branch circuit protection, fuse protection, and double pole protection. These features safeguard connected equipment from electrical faults, surges, and other power anomalies that could damage sensitive server and networking hardware in data center environments.
What type of input connector does this PDU use?
This PDU uses an IEC 60309 3P+G input connector, which is a three-phase connector with ground. This industrial-grade connector type is commonly used in data center power distribution for its reliability and secure connection, supporting the three-phase power delivery that this 17.3 kW capacity PDU requires for optimal performance.
What power capacity is listed for this UPS?
The listed power specification is 17.30 kW, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 230 V AC, which helps position the unit for the right load level and installation role.