Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This CAT6a patch cable delivers 10 Gbit/s data transfer rates over distances up to 100 meters, complying with ANSI/TIA-568-B.2-10 and ANSI/TIA-568.2-D standards. The shielded twisted pair (STP) construction with individual pair shielding minimizes near-end crosstalk (NEXT) and protects against electromagnetic interference (EMI/RFI), ensuring signal integrity in electrically noisy environments.
The 50-micron gold-plated contacts maintain corrosion-resistant connections, while the snagless boot design prevents accidental disconnection. The cable's 26 AWG copper gauge supports IEEE 802.3bt PoE standards, delivering up to 100W power alongside data transmission without overheating concerns.
This section brings together practical product details such as Cable Type, Cable Characteristic, Cable Length, Color Family, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
This CAT6a cable combines high-speed performance with robust construction for reliable network infrastructure. The shielding and quality materials ensure consistent connectivity in commercial and industrial settings where interference and physical wear are concerns.
Interference Protection
Full shielding with EMI/RFI protection maintains signal clarity in environments with electrical noise, while minimized near-end crosstalk ensures data integrity at 10GbE speeds.
- STP construction
- EMI/RFI protection
- Minimized NEXT
Durability Features
The snagless boot prevents accidental disconnection, while gold-plated connectors resist corrosion. The stranded copper conductors and flexible jacket withstand repeated bending without damage.
- Snagless boot design
- Gold-plated contacts
- Stranded conductors
Power over Ethernet Ready
UL-rated wiring (E132276-A) and 26 AWG conductors support IEEE 802.3bt PoE standards, delivering up to 100W for powering devices like VoIP phones and security cameras directly through the network cable.
- IEEE 802.3bt compliant
- 100W PoE support
- UL rated wiring
Deployment / Use Cases
This shielded CAT6a patch cable is ideal for connecting network equipment in office environments, data centers, and commercial installations where 10GbE performance and reliability are essential. The 15-foot length provides flexibility for connecting devices within server racks, between workstations and wall outlets, or in patch panel configurations.
The PoE capability makes this cable particularly valuable for powering network devices without separate power supplies. Install it between switches and PoE-enabled endpoints like VoIP phones, wireless access points, security cameras, or IoT devices. The blue color allows for easy cable management and identification in complex network setups.
Data Center & Server Room
Connect servers, switches, and storage devices with 10GbE performance. The shielding protects against interference in dense server environments, while the snagless boots prevent accidental disconnections during maintenance.
Office Network Infrastructure
Link workstations, printers, and network equipment with reliable CAT6a performance. The PoE support powers VoIP phones and wireless access points directly from network switches, reducing cable clutter and installation complexity.
Highlights
- 15-foot CAT6a Ethernet patch cable supporting 10GbE data transfer rates
- Shielded twisted pair (STP) construction with EMI/RFI protection for reliable performance
- Gold-plated RJ45 connectors with snagless boots for durable, corrosion-resistant connections
- Supports Power over Ethernet (PoE) up to 100W for VoIP phones and security devices
- 26 AWG stranded copper conductors with UL-rated wiring (E132276-A)
- Blue CMG jacket for easy identification and plenum-rated installation
- Compliant with ANSI/TIA-568-B.2-10 and ANSI/TIA-568.2-D standards
- ETL verified and individually tested for quality assurance
- Lifetime limited warranty for long-term reliability
- RoHS, REACH, and WEEE compliant for environmental responsibility
Specifications
| Specifications | |
|---|---|
| Manufacturer | StarTech.com |
| Manufacturer Part Number | C6ASPAT15BL |
| Brand Name | StarTech.com |
| Product Name | Cat6a Ethernet Patch Cable - Shielded (STP) - 15 ft., Blue |
| Packaged Quantity | 1 Each |
| Product Type | Network Cable |
| Technical Information | |
| Cable Type | Category 6a |
| Cable Characteristic | Patch Cable |
| Cable Length | 15 ft (4.57 m) |
| Connector Type on First End | RJ-45 Network - Male |
| Connector Gender on First End | Male |
| Connector on First End Details | 1 x RJ-45 Network - Male |
| Connector Type on Second End | RJ-45 Network - Male |
| Connector Gender on Second End | Male |
| Connector on Second End Details | 1 x RJ-45 Network - Male |
| Connector Plating | Gold |
| Shielding | Yes |
| Jacket Type | CMG |
| Device Supported | Docking Station,Network Device,Notebook,Desktop Computer,Hub,Switch,Router,Print Server,Patch Panel,PoE-enabled Device,VoIP Device |
| American Wire Gauge | 26 AWG |
| Data Transfer Rate | 10 Gbit/s |
| Boot Type | Snagless |
| Features | Molded,EMI/RF Protection,Booted,Strain Relief,Corrosion Resistant,Noise Protection,Stranded,Damage Resistant,Minimized Near-End Crosstalk (NEXT),Rust Resistant,Flexible,Break Resistant,PoE |
| Physical Characteristics | |
| Color Family | Blue |
| Product Color | Blue |
| Miscellaneous | |
| Environmentally Friendly | Yes |
| Environmental Certification | EU RoHS |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) 2,Registration, Evaluation, Authorization and Restriction of Chemicals (REACH),Waste Electrical and Electronic Equipment Directive (WEEE) |
| Country of Origin | China |
| Warranty | |
| Limited Warranty | Lifetime |
User Manual
FAQ
What is the maximum data transfer speed of this CAT6a cable?
This StarTech.com CAT6a Ethernet cable supports data transfer rates up to 10 Gbit/s (10GbE) over distances up to 100 meters. It maintains this high-speed performance while minimizing near-end crosstalk through its shielded construction and compliance with ANSI/TIA-568 standards.
Does this cable support Power over Ethernet (PoE)?
Yes, this cable fully supports Power over Ethernet up to 100W. The 26 AWG stranded copper conductors and UL-rated wiring (E132276-A) are designed to handle IEEE 802.3bt PoE standards, making it suitable for powering devices like VoIP phones, security cameras, and wireless access points directly through the network connection.
What are the benefits of the snagless boot design?
The snagless boots on both RJ45 connectors prevent the retention clips from catching on other cables or equipment during installation and removal. This design reduces the risk of accidental disconnections and connector damage in crowded wiring environments like server racks and patch panels, while still providing strain relief for the cable connections.
Is this cable shielded, and why does that matter?
Yes, this is a shielded twisted pair (STP) cable with full shielding around all four pairs. The shielding protects against electromagnetic interference (EMI) and radio frequency interference (RFI), which is particularly important in environments with electrical noise or when running cables near power sources. This ensures consistent 10GbE performance and data integrity.
What devices are compatible with this Ethernet cable?
This CAT6a patch cable is compatible with any device featuring an RJ45 Ethernet port, including computers, switches, routers, printers, docking stations, patch panels, and PoE-enabled devices like VoIP phones and security systems. It supports multi-speed connections from 10Base-T to 10GbE networks.
What does the CMG jacket rating mean for installation?
The CMG (communications multipurpose general) jacket indicates this cable meets standards for installation in commercial buildings, including plenum spaces where air circulates for heating and cooling systems. The blue color provides easy visual identification for cable management, and the jacket material is flexible yet durable for long-term use in various installation environments.