Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Tripp Lite by Eaton PDU3MV6L2120B 3-Phase Metered PDU - 5. 70 kW - 230V AC - NEMA L21-20P Input - 27 Outlets - 6 L6-20R - 21 5-15/20R - Vertical
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
Power Distribution Architecture
This PDU accepts a 3-phase NEMA L21-20P input at 230V AC and delivers both 208V AC and 120V AC outputs. The 5.70 kW power rating supports high-density equipment loads, with the metered functionality offering visibility into each phase's current draw for balanced power allocation.
- 3-phase 230V AC input via NEMA L21-20P connector
- Outputs: 208V AC on L6-20R outlets, 120V AC on 5-15/20R outlets
- 5.70 kW total power capacity
Outlet Configuration and Connectivity
With 27 total outlets, this PDU accommodates diverse equipment needs. Six NEMA L6-20R outlets provide 208V power for servers and networking gear, while twenty-one NEMA 5-15/20R outlets deliver 120V power for monitors, peripherals, and other standard devices.
- 6 x NEMA L6-20R outlets (208V)
- 21 x NEMA 5-15/20R outlets (120V)
- 6 ft. / 1.8m input line cord included
Key Product Advantages
This PDU combines high power capacity with intelligent monitoring in a space-saving vertical form factor. The built-in current meters deliver per-phase visibility that helps prevent overloads and optimize power usage, while the extensive outlet mix supports both high-voltage and standard equipment in the same rack.
Intelligent Power Monitoring
The integrated current meters display real-time input current for each phase, allowing administrators to monitor load distribution and identify potential imbalances before they cause issues. This metered capability supports efficient capacity planning and reduces the risk of unexpected downtime.
- Per-phase current monitoring via built-in meters
- Proactive load management and overload prevention
- Supports balanced power distribution across phases
Space-Optimized Rack Design
The 0U vertical mounting orientation conserves valuable rack U-space for equipment while providing full-length power distribution. The slim 1.93" width and tool-less button-mount brackets enable quick installation without consuming rack depth, and cord retention brackets keep power cables organized and secure.
- 0U vertical mounting saves rack U-space
- Tool-less button-mount installation
- Cord retention brackets included for cable management
- 70" height fits standard rack enclosures
Deployment / Use Cases
This 3-phase metered PDU is designed for commercial and government IT environments where reliable, monitored power distribution is critical. The TAA compliance makes it suitable for GSA Schedule purchases and federal deployments, while the RoHS environmental compliance aligns with sustainable IT initiatives.
Ideal applications include data center server racks, network closets, telecommunications installations, and laboratory environments requiring both 208V and 120V power distribution with monitoring capabilities. The vertical form factor works particularly well in full-height racks where maximizing equipment density is a priority.
Data Center Server Racks
Provides monitored 3-phase power distribution for high-density server deployments, with the outlet mix supporting both server power supplies (208V) and management console equipment (120V) in the same enclosure.
Government and Education IT
TAA compliance enables procurement through GSA Schedule contracts, making this PDU suitable for federal, state, and educational institutions requiring compliant power distribution solutions.
Physical Profile
The PDU features a vertical rack-mountable design with dimensions of 70" H x 1.93" W x 2.20" D (1778 x 49.02 x 55.88 mm), fitting standard 19" rack enclosures without consuming U-space. The slim profile and 12.57 lb (5700 g) weight facilitate installation in both front and rear rack positions, while the tool-less mounting brackets simplify deployment in various rack environments.
- Width
- 1.93" (49.02 mm)
- Depth
- 2.20" (55.88 mm)
- Height
- 70" (1778 mm)
- Weight
- 12.57 lb (5700 g)
What's in the Box
The package includes the 3-Phase Metered PDU unit, cord retention brackets, rack mounting brackets, and a user manual for installation and operation guidance.
Package contents include 3-Phase Metered PDU Cord Retention Brackets Rack Mounting Brackets User Manual, 3-Phase Metered PDU. These included items support setup, installation, and immediate deployment without needing to source the core bundled accessories separately.
Highlights
- 5.70 kW 3-phase metered PDU with 230V AC input
- 27 total outlets: 6 NEMA L6-20R (208V) and 21 NEMA 5-15/20R (120V)
- Built-in current meters display per-phase input current
- Vertical 0U rack-mountable design saves rack U-space
- Tool-less button-mount installation with included brackets
- NEMA L21-20P input connector with 6 ft. line cord
- TAA Compliant for GSA Schedule purchases
- RoHS environmental compliance
- 2-year limited warranty
- Made in Taiwan with quality construction
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | PDU3MV6L2120B |
| Brand Name | Tripp Lite series |
| Product Series | Metered |
| Product Model | PDU3MV6L2120B |
| Product Name | 3-Phase Metered PDU |
| Product Type | PDU |
| Technical Information | |
| Plug/Connector Type | NEMA L21-20P |
| Receptacle Type | NEMA L6-20R,NEMA 5-15/20R |
| Receptacle Detail | 6 x NEMA L6-20R,21 x NEMA 5-15/20R |
| Power Description | |
| Input Voltage | 230 V AC |
| Output Voltage | 120 V AC,208 V AC |
| Power Rating (Watt) | 5.70 kW |
| Physical Characteristics | |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Height | 70" (1778 mm) |
| Width | 1.93" (49.02 mm) |
| Depth | 2.20" (55.88 mm) |
| Weight (Approximate) | 12.57 lb (5700 g) |
| Miscellaneous | |
| Package Contents | 3-Phase Metered PDU Cord Retention Brackets Rack Mounting Brackets User Manual |
| Country of Origin | Taiwan |
| TAA Compliant | Yes |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What is the power capacity of this PDU?
This Tripp Lite by Eaton PDU delivers 5.70 kW of power capacity with a 230V AC 3-phase input. It distributes this power across 27 outlets, supporting both 208V and 120V equipment simultaneously for comprehensive rack power distribution.
How many outlets does this PDU have and what types are they?
The PDU features 27 total outlets: six NEMA L6-20R outlets providing 208V AC power for servers and networking equipment, and twenty-one NEMA 5-15/20R outlets delivering 120V AC power for monitors, peripherals, and other standard devices.
What does 'metered' mean for this PDU?
Metered refers to the built-in current meters that display real-time input current for each of the three power phases. This allows administrators to monitor load distribution, identify potential imbalances, and prevent circuit overloads through proactive power management.
How is this PDU mounted in a rack?
This PDU uses a vertical 0U rack-mountable design that installs along the side of a standard 19" rack without consuming valuable U-space. It includes tool-less button-mount brackets for easy installation and cord retention brackets to secure power cables and maintain organized cable management.
What is TAA compliance and why does it matter?
TAA (Trade Agreements Act) compliance means this product meets federal acquisition regulations for government purchases, making it eligible for GSA Schedule contracts. This is important for federal agencies, educational institutions, and other organizations requiring compliant IT equipment for government-funded projects.
What warranty comes with this PDU?
Tripp Lite by Eaton provides a 2-year limited warranty for this 3-phase metered PDU. The warranty covers defects in materials and workmanship, offering reliable protection for your power distribution investment in data center and server room environments.
What power capacity is listed for this UPS?
The listed power specification is 5.70 kW, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 230 V AC, which helps position the unit for the right load level and installation role.