Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
The LR604 employs multi-stage protection circuitry to safeguard connected equipment. EMI/RFI filtering reduces electrical noise that can cause data corruption and equipment malfunction. The surge suppression stage absorbs transient spikes up to 340 joules.
Voltage correction circuitry automatically adjusts under- and overvoltages within the 189V-247V range, maintaining stable output power. The unit monitors power conditions continuously and provides visual feedback through front-panel LEDs for line status, protection status, and ground status.
This section brings together practical product details such as Protection Type, Plug/Connector Type, Receptacle Type, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The LR604 combines multiple protection technologies in a single compact unit, eliminating the need for separate surge protectors, voltage regulators, and noise filters. This integrated approach simplifies installation while providing comprehensive equipment protection.
These strengths make the product easier to deploy and manage in real environments, especially where reliability, usability, and day-to-day operational continuity matter. Notable benefits include Multi-Stage Protection, Visual Monitoring.
Multi-Stage Protection
Simultaneously filters EMI/RFI noise, suppresses surge transients, and corrects voltage fluctuations for complete power conditioning.
- 340J surge energy rating
- EMI/RFI noise filtering
- Automatic voltage correction
Visual Monitoring
Front-panel LEDs provide immediate status feedback for line condition, protection status, and grounding integrity.
- Line status indicator
- Protection status LED
- Ground status monitor
Deployment / Use Cases
The LR604 is ideal for protecting sensitive electronics in environments with unstable power quality or electrical noise interference. Its 600W capacity supports multiple devices while maintaining clean, regulated power output.
Common applications include computer workstations, networking equipment, audio/video systems, and laboratory instruments. The compact tower design works well on desktops, while the standard IEC connectors ensure compatibility with most electronic equipment.
This section brings together practical product details such as Protection Type, Plug/Connector Type, Receptacle Type, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Office & IT Environments
Protect computers, monitors, routers, and modems from power anomalies that can cause data loss, hardware damage, or system crashes.
Home Theater & Audio Systems
Eliminate electrical noise that can introduce hum, static, or visual artifacts in audio and video equipment for cleaner signal quality.
Physical Profile
The LR604 features a compact tower design measuring 5.5 inches wide, 5.25 inches high, and 4.8 inches deep. This footprint fits easily on desktops or in equipment racks without consuming excessive space. The unit includes a 6-foot power cord with IEC C14 connector for flexible placement options.
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 5.25" (133.35 mm), 5.50" (139.70 mm), 4.80" (121.92 mm). This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 5.50" (139.70 mm)
- Depth
- 4.80" (121.92 mm)
- Height
- 5.25" (133.35 mm)
- Length
- 6 ft (1.83 m)
What's in the Box
The package includes everything needed for immediate installation and operation.
Highlights
- 600W/600VA load capacity for multiple connected devices
- EMI/RFI filtering eliminates electrical noise interference
- 340-joule surge protection against voltage spikes
- Automatic voltage correction (189V-247V range)
- Three IEC C13 outlets for flexible connectivity
- Front-panel diagnostic LEDs for power status monitoring
- Compact tower design with 6-foot power cord
- RoHS compliant and TAA compliant
- 2-year limited warranty for peace of mind
- Ideal for computers, networking gear, and AV equipment
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | LR604 |
| Brand Name | Tripp Lite series |
| Product Model | LR604 |
| Product Name | LR604 600W 230V Power Conditioner |
| Product Type | Line Conditioner |
| Technical Information | |
| Protection Type | EMI / RFI,AC Noise,AC Surge,Over Voltage,Under Voltage |
| Plug/Connector Type | IEC 60320 C14 |
| Receptacle Type | IEC 320 EN 60320 C13 |
| Receptacles Detail | 3 x IEC 320 EN 60320 C13 |
| Power Description | |
| Load Capacity (VA) | 600 W |
| Load Capacity (Watt) | 600 W |
| Input Voltage | 230 V AC |
| Surge Energy Rating | 340 J |
| Physical Characteristics | |
| Cord Length | 6 ft (1.83 m) |
| Height | 5.25" (133.35 mm) |
| Width | 5.50" (139.70 mm) |
| Depth | 4.80" (121.92 mm) |
| Miscellaneous | |
| Package Contents | LR604 600W 230V Power Conditioner UNIPLUGINT Adapter C13 to CEE7 Schuko Power Cord, 2 m Owner's Manual |
| Country of Origin | Taiwan |
| TAA Compliant | Yes |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What types of power protection does the LR604 provide?
The LR604 provides comprehensive multi-stage protection including EMI/RFI filtering to reduce electrical noise, 340-joule surge suppression against voltage spikes, and automatic voltage correction that adjusts under- and overvoltages within the 189V-247V range. This combination safeguards connected equipment from various power quality issues.
How many devices can I connect to this power conditioner?
The LR604 features three IEC 320 EN 60320 C13 outlets, allowing you to connect up to three compatible devices simultaneously. The unit supports a total load capacity of 600W (600VA), so you should ensure the combined power draw of all connected equipment does not exceed this rating.
What input voltage does the LR604 require?
The LR604 is designed for 230V AC input systems. It automatically corrects voltage fluctuations within the 189V-247V range, making it suitable for regions with unstable grid power or voltage variations. The unit includes a standard IEC C14 input connector.
How does the voltage correction feature work?
The LR604 monitors incoming voltage continuously and automatically adjusts under- and overvoltages within the 189V-247V range. When voltage falls below or rises above optimal levels, the conditioner corrects it to provide stable output power, protecting sensitive electronics from damage caused by voltage irregularities.
What do the front-panel LEDs indicate?
Three diagnostic LEDs provide real-time power status monitoring: the line status LED indicates proper voltage input, the protection status LED confirms the surge protection circuit is active, and the ground status LED verifies proper grounding. These visual indicators help users quickly identify power quality issues.
Is this power conditioner suitable for rack mounting?
The LR604 features a compact tower design measuring 5.5" W × 5.25" H × 4.8" D. While primarily designed for desktop use, its dimensions allow it to fit in standard equipment racks with appropriate shelf mounting. The unit does not include dedicated rack ears but can be secured using universal rack shelves.
What power capacity is listed for this UPS?
The listed power specification is 600 W, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 230 V AC, which helps position the unit for the right load level and installation role.