Tripp Lite by Eaton PDU3XMV6G20 Metered 45-Outlet 11. 5kVA PDU - 3-Phase 415V Input - 36x C13 & 9x C19 Outlets - 0U Rack-Mountable
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This metered PDU accepts three-phase input power from 380V to 415V AC and delivers single-phase output at 220V, 230V, or 240V AC configurations. The 11.5 kVA capacity supports substantial equipment loads across 45 strategically arranged outlets.
The IEC 60309 16A input connector ensures secure international compatibility, while the outlet mix of 36 C13 and 9 C19 receptacles accommodates both standard and high-power server and networking equipment. A 6-foot (1.8m) line cord provides flexible installation positioning.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Input Voltage Range, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
This PDU combines high-density power distribution with intelligent monitoring in a space-saving vertical format. The toolless button-mount installation simplifies deployment, while cord retention brackets prevent accidental disconnections in vibration-prone environments.
Intelligent Power Monitoring
Three digital meters display real-time load levels per phase in amps, enabling precise capacity planning and preventing unbalanced loading across phases.
- Per-phase current monitoring
- Visual load level indicators
- Prevents circuit overloads
High-Density Outlet Configuration
With 45 outlets in a mix of C13 and C19 types, this PDU supports diverse equipment from servers and switches to storage arrays and networking gear.
- 36 C13 outlets for standard equipment
- 9 C19 outlets for high-power devices
- Optimized outlet spacing
Deployment / Use Cases
The PDU3XMV6G20 is engineered for data centers, server rooms, and network closets where high-density power distribution with monitoring capabilities is essential. Its vertical 0U mounting preserves valuable rack space for active equipment while providing centralized power management.
Ideal for multi-rack installations, this PDU supports equipment requiring three-phase power input while delivering single-phase output to individual devices. The metering functionality makes it particularly valuable for capacity planning, chargeback accounting, and identifying underutilized circuits in colocation environments.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Input Voltage Range, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Data Center Power Distribution
Deploy in server racks to consolidate power distribution for multiple devices while monitoring load levels across all three phases.
Network Infrastructure Support
Power switches, routers, and other networking equipment with the outlet mix and monitoring needed for critical communications infrastructure.
Physical Profile
Designed for vertical mounting between rack rails, this PDU measures 70" tall with a slim 2.20" width and 1.93" depth profile. The 0U mounting configuration eliminates the need for rack unit space allocation, while the 9-pound weight ensures manageable installation. The vertical orientation provides excellent cable management opportunities with downward-facing outlets that keep power cords organized and accessible.
- Width
- 2.20" (55.88 mm)
- Depth
- 1.93" (49.02 mm)
- Height
- 70" (1778 mm)
- Weight
- 9 lb (4082.33 g)
What's in the Box
The package includes all necessary components for immediate deployment in standard 19-inch rack environments.
Highlights
- 11.5 kVA three-phase power capacity for high-density equipment loads
- 45 total outlets with 36 C13 and 9 C19 configurations
- Three digital meters display per-phase load levels in amps
- Vertical 0U rack-mount design saves valuable rack space
- IEC 60309 16A input connector with 6-foot line cord
- Toolless button-mount installation for quick deployment
- Includes cord retention brackets to prevent accidental disconnections
- RoHS compliant and TAA compliant for government deployments
- 2-year limited warranty for peace of mind
- Made in Taiwan with quality manufacturing standards
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | PDU3XMV6G20 |
| Brand Name | Tripp Lite series |
| Product Series | Metered |
| Product Model | PDU3XMV6G20 |
| Product Name | Metered PDU3XMV6G20 45-Outlets 11.5kVA PDU |
| Product Type | PDU |
| Technical Information | |
| Plug/Connector Type | IEC 60309 16A |
| Receptacle Type | IEC 60320 C19,IEC 60320 C13 |
| Receptacle Detail | 9 x IEC 60320 C19,36 x IEC 60320 C13 |
| Power Description | |
| Input Voltage Range | 380 V AC - 415 V AC |
| Output Voltage | 220 V AC,230 V AC,240 V AC |
| Power Rating (VA) | 11.50 kVA |
| Physical Characteristics | |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Height | 70" (1778 mm) |
| Width | 2.20" (55.88 mm) |
| Depth | 1.93" (49.02 mm) |
| Weight (Approximate) | 9 lb (4082.33 g) |
| Miscellaneous | |
| Package Contents | Metered PDU3XMV6G20 45-Outlets 11.5kVA PDU Cord Retention Brackets Mounting Brackets |
| Country of Origin | Taiwan |
| TAA Compliant | Yes |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What is the power capacity of this PDU?
The Tripp Lite by Eaton PDU3XMV6G20 provides 11.5 kVA (kilovolt-amperes) of power capacity. This substantial rating supports high-density equipment installations in data center and server room environments, making it suitable for powering multiple servers, storage arrays, and networking devices simultaneously.
How many outlets does this PDU have and what types?
This PDU features 45 total outlets with a mix of connector types: 36 IEC 60320 C13 outlets for standard equipment and 9 IEC 60320 C19 outlets for higher-power devices. This configuration accommodates diverse IT infrastructure from servers and switches to storage systems and network appliances.
What input voltage does this PDU require?
The PDU accepts three-phase input power ranging from 380V to 415V AC. This voltage range accommodates common international three-phase power standards, making the unit suitable for deployment in various geographic regions with different electrical infrastructure.
How is this PDU mounted in a rack?
This PDU uses a vertical 0U mounting configuration that installs between the front and rear rails of a standard 19-inch rack. The toolless button-mount design simplifies installation, while the 70-inch height and slim 2.20-inch width maximize space efficiency without consuming rack units that could be used for active equipment.
What monitoring capabilities does this metered PDU provide?
Three digital meters display real-time output load levels per phase in amps. This monitoring enables administrators to track power consumption across all three phases, identify unbalanced loads, prevent circuit overloads, and optimize power distribution in multi-phase installations.
What compliance standards does this PDU meet?
This PDU is RoHS (Restriction of Hazardous Substances) compliant and TAA (Trade Agreements Act) compliant. RoHS compliance ensures environmentally responsible manufacturing, while TAA compliance makes the unit eligible for U.S. government procurement where TAA requirements apply.
What power capacity is listed for this UPS?
The listed power specification is 11.50 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 380 V AC - 415 V AC, which helps position the unit for the right load level and installation role.