Tripp Lite by Eaton PDU3XMV6G32 Metered PDU - 23 kW - 42 Outlets - 36 C13 - 6 C19 - 0U Vertical Rackmount - IEC 60309 32A 3-Phase Input
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This metered PDU accepts 380-400 V AC three-phase input through an IEC 60309 32A Red 3P+N+E connector and distributes 200-240 V AC output across 42 outlets. The 23 kW power rating supports substantial server and networking equipment loads with overload protection for connected devices.
The visual meter provides real-time monitoring of output amps per bank, total kW consumption, and input voltage, enabling proactive power management. The unit's 32 A input current capacity and three-phase design ensure stable power delivery for critical infrastructure.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Input Voltage Range, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
This PDU combines high power capacity with intelligent monitoring in a space-efficient vertical rackmount design. The visual meter eliminates guesswork in power management, while the comprehensive outlet configuration supports diverse equipment requirements.
High-Density Power Distribution
With 42 outlets (36 C13 and 6 C19), this PDU supports extensive server, storage, and networking deployments without requiring multiple power distribution units.
- 23 kW total capacity
- Mixed outlet types for equipment flexibility
- Cord retention sleeves included
Intelligent Power Monitoring
The built-in meter displays real-time electrical parameters, enabling data center managers to optimize power usage and identify potential issues before they affect operations.
- Output amps per bank visibility
- Total kW consumption tracking
- Input voltage monitoring
Space-Optimized Installation
The 0U vertical design conserves valuable rack space while providing full power distribution capabilities. The toolless button-mount system simplifies installation and maintenance.
- Zero rack units required
- Vertical mounting orientation
- Quick deployment with included hardware
Deployment / Use Cases
The PDU3XMV6G32 is designed for data centers, server rooms, and network closets where reliable three-phase power distribution is essential. Its 23 kW capacity and 42 outlets make it suitable for high-density rack deployments supporting multiple servers, storage arrays, and networking equipment.
Enterprise IT departments will appreciate the visual monitoring capabilities for capacity planning and load balancing. The TAA compliance makes this unit suitable for government and educational installations with specific procurement requirements.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Input Voltage Range, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Data Center Power Distribution
Deploy in server racks to distribute three-phase power to multiple equipment tiers while monitoring consumption patterns and optimizing electrical infrastructure.
High-Density Server Environments
Support blade server chassis, storage arrays, and networking gear with the mixed C13/C19 outlet configuration and 23 kW power capacity.
Physical Profile
This vertical rackmount PDU measures 70" (1778 mm) in height with a slim 2.17" (55.12 mm) width and 2.49" (63.25 mm) depth profile. The 0U design installs vertically in standard 19" racks without consuming horizontal rack space. The compact footprint and 14.29 lb weight facilitate handling during installation while maintaining structural integrity for long-term deployment.
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 0U, 2.17" (55.12 mm), 2.49" (63.25 mm), 14.29 lb (6481.83 g). This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 2.17" (55.12 mm)
- Depth
- 2.49" (63.25 mm)
- Height
- 0U
- Weight
- 14.29 lb (6481.83 g)
What's in the Box
The package includes all necessary components for immediate deployment and secure operation.
Highlights
- 23 kW three-phase power distribution capacity
- 42 total outlets: 36 IEC 60320 C13 and 6 IEC 60320 C19
- Visual meter displays output amps per bank, total kW, and input voltage
- 0U vertical rackmount design conserves rack space
- IEC 60309 32A Red 3P+N+E three-phase input connector
- Toolless button-mount installation system
- Includes cord retention sleeves for secure connections
- TAA compliant for government and educational procurement
- RoHS environmental compliance
- 2-year limited warranty
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | PDU3XMV6G32 |
| Brand Name | Tripp Lite series |
| Product Line | Metered |
| Product Model | PDU3XMV6G32 |
| Product Name | Metered PDU3XMV6G32 42 Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| Plug/Connector Type | IEC 60309 32A Red 3P+N+E |
| Receptacle Type | IEC 60320 C19,IEC 60320 C13 |
| Receptacle Detail | 6 x IEC 60320 C19,36 x IEC 60320 C13 |
| Protection Type | Overload Protection |
| Power Description | |
| Input Voltage Range | 380 V AC - 400 V AC |
| Output Voltage | 200 V AC,220 V AC,230 V AC,240 V AC |
| Power Rating (Watt) | 23 kW |
| Input Current | 32 A |
| Physical Characteristics | |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Rack Height | 0U |
| Height | 70" (1778 mm) |
| Width | 2.17" (55.12 mm) |
| Depth | 2.49" (63.25 mm) |
| Weight (Approximate) | 14.29 lb (6481.83 g) |
| Miscellaneous | |
| Package Contents | Metered PDU3XMV6G32 42 Outlets PDU Cord Retention Sleeves (36 C14, 6 C19) Spare Installation Buttons (2 9mm / 4 6mm) Rack Mounting Brackets Owner's Manual |
| Country of Origin | Taiwan |
| TAA Compliant | Yes |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What power capacity does this PDU provide?
The Tripp Lite by Eaton PDU3XMV6G32 delivers 23 kW of three-phase power distribution. This capacity supports high-density server and networking equipment deployments in data center environments, with the visual meter enabling real-time monitoring of power consumption across connected devices.
How many outlets does this PDU have and what types?
This PDU features 42 total outlets with a mixed configuration: 36 IEC 60320 C13 outlets and 6 IEC 60320 C19 outlets. This combination supports standard server power cords (C13) along with higher-current equipment requiring C19 connections, providing flexibility for diverse IT infrastructure deployments.
What rack space does this PDU require for installation?
The PDU3XMV6G32 uses a 0U vertical rackmount design, meaning it installs vertically in standard 19" racks without consuming horizontal rack units. This space-efficient approach maximizes usable rack space for servers and networking equipment while providing full power distribution capabilities.
What input voltage does this PDU accept?
This metered PDU accepts three-phase input voltage in the 380-400 V AC range through an IEC 60309 32A Red 3P+N+E connector. The unit then distributes 200-240 V AC output to connected equipment, making it suitable for international three-phase power infrastructure.
What monitoring capabilities does the visual meter provide?
The built-in visual meter displays output amps per individual bank, total kW consumption, and input voltage in real time. This enables data center managers to monitor power usage patterns, balance loads across phases, and identify potential electrical issues before they affect critical infrastructure operations.
Is this PDU compliant with government procurement requirements?
Yes, the PDU3XMV6G32 is TAA (Trade Agreements Act) compliant, making it suitable for government, educational, and institutional procurement where specific compliance standards are required. The unit also meets RoHS environmental standards and includes a 2-year limited warranty for added reliability assurance.
What power capacity is listed for this UPS?
The listed power specification is 23 kW, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 380 V AC - 400 V AC, which helps position the unit for the right load level and installation role.