Tripp Lite by Eaton SU3000LCD2UHVTF SmartOnline 3KVA Rack/Tower UPS - 4U - 230V AC Input - 2. 7kW - Pure Sine Wave
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This UPS operates on a 230 V AC single-phase input and delivers regulated 120 V AC or 208 V AC output at 60 Hz. The double-conversion architecture continuously conditions incoming power, delivering clean, stable output regardless of input quality. A built-in EMI/RFI noise filter and 570 J surge energy rating provide additional protection against electrical interference and transient voltage spikes.
The DC system operates at 72 V DC, supporting hot-swappable, user-replaceable batteries. The unit includes comprehensive monitoring via four front-panel LEDs indicating AC input, AC output, battery status, and fault conditions.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The SmartOnline SU3000LCD2UHVTF combines industrial-grade power protection with practical deployment flexibility. Its online double-conversion design ensures zero-interruption power during outages or fluctuations, while the pure sine wave output guarantees safe operation for equipment with active PFC power supplies.
Mission-Critical Runtime
Delivers 5 minutes of runtime at full load and extends to 13.5 minutes at half load, providing sufficient time for graceful system shutdowns or generator startup during extended outages.
- 5-minute full-load backup
- 13.5-minute half-load backup
- 3-hour typical recharge time
Comprehensive Outlet Configuration
Features 20 total outlets across three NEMA types: 12 NEMA 5-15/20R, 6 NEMA 6-15/20R, and 2 NEMA L6-20R receptacles, accommodating diverse equipment power requirements.
- 12× NEMA 5-15/20R
- 6× NEMA 6-15/20R
- 2× NEMA L6-20R
Deployment / Use Cases
This UPS is purpose-built for environments where power continuity is non-negotiable. Its 3 kVA capacity and rack-optimized design make it ideal for protecting server racks, network closets, and data center equipment where space is at a premium and reliability is paramount.
The rack/tower dual-format design allows installation in standard 19-inch server racks using the included 4U rack-mounting hardware, or as a standalone tower in locations where rack infrastructure isn't available. This flexibility supports deployment across diverse IT infrastructures from enterprise data centers to smaller network rooms.
Server & Network Protection
Safeguards critical servers, switches, routers, and storage arrays against power disturbances that can cause data corruption, hardware damage, or unscheduled downtime.
Data Center & Computer Room
Provides clean, regulated power to sensitive IT equipment in controlled environments, supporting uptime SLAs and protecting against revenue-impacting outages.
Physical Profile
The UPS measures 6.97" (177 mm) high, 17.32" (440 mm) wide, and 24.25" (616 mm) deep, occupying 4U of vertical rack space. Weighing 133.82 lb (60.7 kg), the unit is designed for stable rack mounting with reinforced chassis construction. The front-panel LCD display provides real-time status monitoring and configuration access.
- Width
- 17.32" (440 mm)
- Depth
- 24.25" (616 mm)
- Height
- 6.97" (177 mm)
- Weight
- 133.82 lb (60699.73 g)
What's in the Box
The package includes all necessary components for immediate deployment and management.
Highlights
- 3 kVA / 2.7 kW double-conversion online UPS with pure sine wave output
- 5-minute runtime at full load, extending to 13.5 minutes at half load
- 4U rack/tower form factor with 230 V AC input and 120/208 V AC output
- 20 total outlets across NEMA 5-15/20R, 6-15/20R, and L6-20R receptacles
- Hot-swappable, user-replaceable batteries with 3-hour typical recharge
- Zero transfer time with online double-conversion topology
- Network management via SNMP, DB9, and USB interfaces
- Front-panel LCD with status indicators and configuration controls
- Includes step-down isolation transformer for voltage conversion
- 2-year limited warranty with RoHS environmental compliance
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | SU3000LCD2UHVTF |
| Brand Name | Tripp Lite series |
| Product Line | SmartOnline |
| Product Model | SU3000LCD2UHVTF |
| Product Name | SmartOnline SU3000LCD2UHVTF 3KVA Rack/Tower UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | NEMA L6-20P |
| Receptacle Type | NEMA 5-15/20R,NEMA 6-15/20R,NEMA L6-20R |
| Receptacle Detail | 12 x NEMA 5-15/20R,6 x NEMA 6-15/20R,2 x NEMA L6-20R |
| Transfer Time | 0 ns |
| EMI/RFI Noise Filter | Yes |
| Phase | Single Phase |
| Energy Saving | High Efficiency Economy Mode Operation; Individually Controllable Load Banks |
| Application/Usage | Mission Critical Equipment,Server,Network Equipment,Data Center,Computer Room,Network Closet |
| Power Description | |
| Load Capacity (VA) | 3 kVA |
| Load Capacity (Watt) | 2.70 kW |
| Input Voltage | 230 V AC |
| Output Voltage | 120 V AC,208 V AC |
| Output Frequency | 60 Hz |
| Waveform Type | Pure Sine Wave |
| Surge Energy Rating | 570 J |
| Management | |
| Network Management | SNMP/DB9/USB |
| Alarm | Power Failure,Low Battery,Overload,Fault |
| Controls/Indicators | |
| Status Indicators | 4 Front Panel LEDs: AC Input (Green) AC Output (Green) Battery (Yellow) Fault (Red) |
| Interfaces/Ports | |
| Serial Port | Yes |
| EPO Port | Yes |
| USB (HID Compliant) Port | Yes |
| Battery Information | |
| DC System Voltage | 72 V DC |
| Backup/Run Time (Full Load) | 5 Minute |
| Backup/Run Time (Half Load) | 13.50 Minute |
| Hot Swappable | Yes |
| Typical Battery Recharge Time | 3 Hour |
| Replaceable Battery | Yes |
| Environmental Conditions | |
| Maximum Operating Elevation | 9842.52 ft (3000000 mm) |
| Storage Temperature | 5°F (-15°C) - 122°F (50°C) |
| Maximum Operating Temperature | 104°F (40°C) |
| Thermal Dissipation | 933 BTU/h |
| Physical Characteristics | |
| Height | 6.97" (177 mm) |
| Width | 17.32" (440 mm) |
| Depth | 24.25" (616 mm) |
| Rack Height | 4U |
| Form Factor | Rack/Tower |
| Weight (Approximate) | 133.82 lb (60699.73 g) |
| Miscellaneous | |
| Package Contents | SmartOnline SU3000LCD2UHVTF 3KVA Rack/Tower UPS SU5000XFMRT2U20 2U 208V to 120V Step-Down Isolation Transformer USB Cable DB9 Cable EPO Cable Rack-mounting Hardware Owner's Manual |
| Country of Origin | China |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What is the power capacity of this UPS?
The Tripp Lite SmartOnline SU3000LCD2UHVTF provides 3 kVA (3000 VA) of apparent power and 2.7 kW (2700 watts) of real power capacity. This rating supports mission-critical equipment including servers, network gear, and storage arrays that require clean, continuous power protection.
How long will this UPS run during a power outage?
At full 2.7 kW load, the UPS provides 5 minutes of runtime. At half load (1.35 kW), runtime extends to 13.5 minutes. These durations allow sufficient time for graceful system shutdowns or for backup generators to start and stabilize during extended power interruptions.
What input voltage does this UPS require?
This UPS requires a 230 V AC single-phase input. The unit is designed for standard North American 230V circuits and includes a NEMA L6-20P plug for connection to appropriate power sources in data centers, server rooms, and network closets.
Can this UPS be installed in a server rack?
Yes, the SU3000LCD2UHVTF features a dual rack/tower design. It occupies 4U of vertical space in standard 19-inch server racks and includes all necessary rack-mounting hardware. The unit can also operate as a standalone tower where rack infrastructure isn't available.
What types of outlets does this UPS have?
The UPS provides 20 total outlets: 12 NEMA 5-15/20R receptacles, 6 NEMA 6-15/20R receptacles, and 2 NEMA L6-20R receptacles. This configuration supports diverse equipment from standard servers and networking gear to higher-power devices requiring 208V or 240V connections.
How is this UPS managed and monitored?
Management options include SNMP for network monitoring, DB9 serial for legacy systems, and USB for direct computer connection. The front panel features an LCD display with four status LEDs indicating AC input, AC output, battery status, and fault conditions for at-a-glance monitoring.
What power capacity is listed for this UPS?
The listed power specification is 3 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 230 V AC, which helps position the unit for the right load level and installation role.