Tripp Lite by Eaton SU3000RTXLCD2UTAA SmartOnline 3000VA 2. 70kW 2U Rack/Tower Online UPS - Pure Sine Wave - 6 Outlets - LCD Display
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This online UPS employs double-conversion technology, continuously converting AC input to DC and back to AC, isolating connected equipment from all power anomalies. It accepts input voltages from 100-120V AC and delivers stable output across 100-127V AC, supporting both 50Hz and 60Hz frequencies.
The unit features a 72V DC battery system with hot-swappable, replaceable lead-acid batteries. Advanced management options include dry contact, DB-9 RS-232, and SNMP/HTTP remote monitoring, while an EPO port enables emergency power-off integration. Audible alarms and status LEDs alert users to power failures, low battery, overloads, and other critical events.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
Zero-Transfer Online Protection
Double-conversion topology ensures uninterrupted power with pure sine wave output, safeguarding sensitive servers, networking gear, and medical devices from sags, surges, and harmonics.
- 0 ns transfer time
- Pure sine wave output
- Isolates equipment from grid noise
Flexible Deployment
The 2U rack/tower design includes rack-mounting hardware and tower support stands, allowing installation in server racks or as a standalone unit in offices, data closets, or industrial settings.
- 2U rack height
- Includes rack and tower hardware
- Fits standard 19-inch racks
Comprehensive Monitoring
An LCD display shows site power status, operating data, and configuration menus, while multiple interfaces enable local and remote management for proactive power management.
- LCD with status and configuration
- SNMP/HTTP remote monitoring
- Dry contact and RS-232 ports
Deployment / Use Cases
The SU3000RTXLCD2UTAA is designed for environments where power continuity is non-negotiable. Its 3000VA capacity and pure sine wave output make it suitable for protecting servers, network switches, routers, storage arrays, and telecommunications equipment in data centers, network operations centers, and enterprise server rooms.
In healthcare, education, government, and military applications, this UPS ensures critical systems remain operational during outages, supporting patient monitoring, emergency communications, and secure data processing. Industrial and non-critical device protection is also supported, with robust surge suppression and noise filtering for manufacturing controls, lab instruments, and point-of-sale systems.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Physical Profile
The UPS measures 3.41" (86.61 mm) in height, 17.33" (440.18 mm) in width, and 23.82" (605.03 mm) in depth, occupying 2U of rack space. Its 63.06 lb weight and included rack-mounting hardware facilitate secure installation in standard 19-inch racks, while tower support stands enable freestanding placement where rack mounting is not available.
- Width
- 17.33" (440.18 mm)
- Depth
- 23.82" (605.03 mm)
- Height
- 3.41" (86.61 mm)
- Weight
- 63.06 lb (28603.53 g)
- Length
- 8 ft (2.44 m)
What's in the Box
The package includes all necessary components for immediate deployment in rack or tower configurations.
Highlights
- 3000VA/2.70kW double-conversion online UPS with pure sine wave output
- 2U rack/tower form factor includes rack-mounting hardware and tower stands
- Zero transfer time and 0 ns switching for uninterrupted power
- LCD display shows real-time status, operating data, and configuration
- 6 x NEMA 5-20R and 1 x NEMA L5-30R outlets for versatile device connectivity
- Hot-swappable, replaceable lead-acid battery with 3-hour recharge time
- SNMP/HTTP, dry contact, and RS-232 remote monitoring and management
- Energy Star certified with 91.6% efficiency in AC mode, 96.8% in Eco mode
- TAA compliant and RoHS/REACH environmental compliance
- 2-year limited warranty for reliable long-term protection
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | SU3000RTXLCD2UTAA |
| Brand Name | Tripp Lite series |
| Product Line | SmartOnline |
| Product Model | SU3000RTXLCD2UTAA |
| Product Name | SmartOnline SU3000RTXLCD2UTAA 3000VA Rack/tower UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | NEMA L5-30P |
| Receptacle Type | NEMA 5-20R,NEMA L5-30R |
| Receptacle Detail | 6 x NEMA 5-20R,1 x NEMA L5-30R |
| Cord Length | 8 ft (2.44 m) |
| Transfer Time | 0 ns |
| EMI/RFI Noise Filter | Yes |
| Phase | Single Phase |
| Energy Saving | Green Energy-Saving |
| Efficiency Detail | 91.6% (AC Mode),96.8% (Eco Mode) |
| Application/Usage | Mission Critical Equipment,IT,Network,Education,Healthcare,Military,Government,Network Device,IT Equipment,Non-critical Device,Industrial Equipment |
| Surge Suppression | Yes |
| Features | Audible Alarm,Cold Start Function |
| Power Description | |
| Load Capacity (VA) | 3 kVA |
| Load Capacity (Watt) | 2.70 kW |
| Input Voltage | 100 V AC,110 V AC,120 V AC |
| Input Current | 24 A |
| Output Voltage | 100 V AC,110 V AC,115 V AC,120 V AC,127 V AC |
| Output Frequency | 50 Hz,60 Hz |
| Waveform Type | Pure Sine Wave |
| Surge Energy Rating | 190 J |
| Input Power Factor | 0.99 |
| Output Power Factor | 0.9 |
| Display & Graphics | |
| Display | LCD |
| Management | |
| Network Management | Dry Contact,DB-9 RS-232,SNMP/HTTP Remote Monitoring |
| Alarm | UPS StartUp,Power Failure,Low Battery,Overload,UPS Fault,Remote Shutdown |
| Controls/Indicators | |
| Status Indicators | LCD Display: Site Power Status and Operating Data Plus Configuration of Voltage Frequency Operating Mode Alarm Function LED Indicators: 4 Status-indicating LEDs |
| Interfaces/Ports | |
| Serial Port | Yes |
| USB | Yes |
| EPO Port | Yes |
| Number of USB Ports | 1 |
| Battery Information | |
| DC System Voltage | 72 V DC |
| Battery Characteristics | Valve-regulated |
| Battery Chemistry | Lead Acid |
| Backup/Run Time (Full Load) | 4.80 Minute |
| Backup/Run Time (Half Load) | 13.90 Minute |
| Hot Swappable | Yes |
| Typical Battery Recharge Time | 3 Hour |
| Replaceable Battery | Yes |
| Environmental Conditions | |
| Maximum Operating Elevation | 10000 ft (3048000 mm) |
| Storage Temperature | -13°F (-25°C) - 131°F (55°C) |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Operating Temperature | 104°F (40°C) |
| Sound Emission | 47 dB |
| Thermal Dissipation | 1462 BTU/h |
| Physical Characteristics | |
| Height | 3.41" (86.61 mm) |
| Width | 17.33" (440.18 mm) |
| Depth | 23.82" (605.03 mm) |
| Rack Height | 2U |
| Form Factor | Rack/Tower |
| Weight (Approximate) | 63.06 lb (28603.53 g) |
| Miscellaneous | |
| Package Contents | SmartOnline SU3000RTXLCD2UTAA 3000VA Rack/tower UPS USB Cable DB9 Cable Rack-mounting Hardware Tower Support Stands Safety Instructions Quick Start Guide |
| Energy Star | Yes |
| Country of Origin | Taiwan |
| TAA Compliant | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS),Registration, Evaluation, Authorization and Restriction of Chemicals (REACH) |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What is the runtime of this UPS at full load?
The SU3000RTXLCD2UTAA provides up to 4.80 minutes of backup runtime at full load (2.70 kW). At half load, runtime extends to approximately 13.90 minutes, allowing sufficient time for graceful shutdowns or continued operation during short outages.
Can this UPS be installed in both rack and tower configurations?
Yes, this UPS supports both rack and tower deployments. It is a 2U rack-mountable unit and includes rack-mounting hardware for standard 19-inch racks. Tower support stands are also included for freestanding installation in offices or locations without rack enclosures.
What types of outlets does this UPS have?
This UPS features six NEMA 5-20R outlets and one NEMA L5-30R outlet, providing versatile connectivity for servers, networking equipment, and other devices. The input plug is a NEMA L5-30P, and the cord length is 8 ft (2.44 m).
How is this UPS managed and monitored?
Management options include an LCD display for local status and configuration, plus dry contact, DB-9 RS-232, and SNMP/HTTP interfaces for remote monitoring. These allow integration with network management systems, enabling alerts for power failures, low battery, overloads, and remote shutdown capabilities.
What is the battery recharge time?
The typical battery recharge time is 3 hours. The UPS uses a hot-swappable, valve-regulated lead-acid battery system with a 72V DC voltage, allowing battery replacement without powering down connected equipment for minimal downtime.
Is this UPS suitable for sensitive electronic equipment?
Yes, its double-conversion online topology delivers pure sine wave output with zero transfer time, providing clean power that protects sensitive servers, medical devices, and networking gear from sags, surges, harmonics, and other grid disturbances. EMI/RFI noise filtering and surge suppression further enhance protection.
What power capacity is listed for this UPS?
The listed power specification is 3 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 100 V AC,110 V AC,120 V AC, which helps position the unit for the right load level and installation role.