Product Features
Technical Overview
This double conversion online UPS operates with true online topology, continuously conditioning incoming AC power to DC and then back to clean AC output. The 6 kVA/6 kW capacity at 230V input delivers pure sine wave output adjustable between 200-240V AC, maintaining 60Hz frequency stability. A 1680-joule surge energy rating and EMI/RFI noise filtering protect connected equipment from power anomalies.
The front panel features a rotatable LCD display with selectable monitoring options and physical controls for navigation and power management. Four status LEDs provide at-a-glance indication of AC input, AC output, battery mode, and fault conditions. The DC system operates at 192V with valve-regulated lead-acid battery chemistry, supporting hot-swappable replacement without system shutdown.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
The SmartOnline SU6KRT3UX combines robust power protection with flexible deployment options for IT infrastructure. Its double conversion technology ensures complete isolation from utility power issues, while the zero transfer time maintains uninterrupted operation during transitions between power sources.
Flexible Power Distribution
Provides 6 IEC 60320 C13 and 4 IEC 60320 C19 receptacles plus hardwired connection options, accommodating diverse equipment configurations with proper strain relief provisions.
- 6 x C13 outlets
- 4 x C19 outlets
- Hardwired capability
- Included strain reliefs
Comprehensive Management
The pre-installed WEBCARDLXMINI network interface card enables remote monitoring and control through industry-standard protocols, with Auto Probe feature for automatic network discovery and configuration.
- SNMP/Telnet/SSH support
- Auto Probe feature
- Front panel LCD control
- EPO port for emergency shutdown
Maintenance & Serviceability
Hot-swappable battery design allows replacement without system downtime, while the 3-hour typical recharge time ensures rapid restoration of backup capacity after use.
- Hot-swappable batteries
- 3-hour recharge
- Replaceable battery packs
- Optional external battery support
Deployment / Use Cases
The SU6KRT3UX is engineered for environments where power quality and availability directly impact operational continuity. Its 6kVA capacity and rack/tower flexibility make it suitable for server rooms, network closets, and telecommunications installations requiring reliable backup power for critical systems.
In data center applications, the unit protects server racks, storage arrays, and network switches from power disturbances. For telecommunications infrastructure, it ensures uninterrupted operation of voice and data equipment. The system also supports mission-critical computing equipment in healthcare, financial, and industrial control environments where even brief power interruptions are unacceptable.
Server Room Protection
Provides clean power to server racks with sufficient runtime for graceful shutdown or continued operation during brief outages, with network management for remote monitoring.
- 6kW server support
- Network management
- Graceful shutdown capability
- Rack-mount ready
Network Infrastructure
Protects switches, routers, and telecommunications equipment with pure sine wave output compatible with sensitive electronics, maintaining connectivity during power events.
- Pure sine wave output
- EMI/RFI filtering
- Multiple outlet types
- Zero transfer time
Physical Profile
Designed for both rack and tower deployment, the SU6KRT3UX occupies 3U of rack space with dimensions of 5.16" height, 17.52" width, and 30" depth. The 117.59-pound unit includes integrated rack-mounting hardware for secure installation in standard 19-inch racks. The front panel LCD rotates for optimal viewing in either orientation, while the form factor accommodates data center airflow requirements with 1300 BTU/h thermal dissipation.
- Width
- 17.52" (445 mm)
- Depth
- 30" (762 mm)
- Height
- 5.16" (131 mm)
- Weight
- 117.59 lb (53340 g)
What's in the Box
The SU6KRT3UX ships complete with all necessary components for immediate deployment in rack or tower configurations.
Highlights
- 6 kVA/6 kW double conversion online UPS with pure sine wave output
- Zero transfer time between online and battery modes for uninterrupted operation
- 3U rack/tower form factor with rotatable front panel LCD display
- Pre-installed WEBCARDLXMINI network management card with SNMP/Telnet/SSH support
- Hot-swappable valve-regulated lead-acid batteries with 3-hour typical recharge
- 6 x IEC C13 and 4 x IEC C19 outlets plus hardwired connection options
- Unity power factor (1.0) equalizes VA and wattage for maximum equipment support
- ENERGY STAR certified for reduced energy consumption and operating costs
- Supports optional external battery packs for extended runtime requirements
- 2-year limited warranty with TAA compliance and RoHS environmental standards
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | SU6KRT3UX |
| Brand Name | Tripp Lite series |
| Product Line | SmartOnline |
| Product Model | SU6KRT3UX |
| Product Name | SmartOnline SU6KRT3UX 6kVA Rack/Tower UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | Hardwired |
| Receptacle Type | IEC 60320 C13,IEC 60320 C19,Hardwired |
| Receptacle Detail | 6 x IEC 60320 C13,4 x IEC 60320 C19 |
| Overload Protection | Yes |
| Transfer Time | 0 ns |
| EMI/RFI Noise Filter | Yes |
| Phase | Single Phase |
| Application/Usage | Network Equipment,Telecommunication,Mission Critical Equipment,Data Center,Computer Room,Server |
| Power Description | |
| Load Capacity (VA) | 6 kVA |
| Load Capacity (Watt) | 6 kW |
| Input Voltage | 230 V AC |
| Output Voltage | 200 V AC,208 V AC,220 V AC,230 V AC,240 V AC |
| Input Frequency | 60 Hz |
| Output Frequency | 60 Hz |
| Waveform Type | Pure Sine Wave |
| Surge Energy Rating | 1680 J |
| Management | |
| Network Management | SNMP/Telnet/SSH |
| Alarm | UPS Power Condition |
| Controls/Indicators | |
| Status Indicators | Front Panel LCD Display: Selectable LCD Display Escape Page Up Page Down Enter and Power buttons enable UPS control Detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats 4 Front-panel LEDs: AC input AC output Battery mode Fault conditions |
| Interfaces/Ports | |
| Serial Port | Yes |
| EPO Port | Yes |
| USB (HID Compliant) Port | Yes |
| Battery Information | |
| DC System Voltage | 192 V DC |
| Battery Characteristics | Valve-regulated |
| Battery Chemistry | Lead Acid |
| Backup/Run Time (Full Load) | 3 Minute |
| Backup/Run Time (Half Load) | 8.50 Minute |
| Hot Swappable | Yes |
| Typical Battery Recharge Time | 3 Hour |
| Replaceable Battery | Yes |
| Environmental Conditions | |
| Maximum Operating Elevation | 6562 ft (2000097.60 mm) |
| Storage Temperature | 5°F (-15°C) - 122°F (50°C) |
| Maximum Operating Temperature | 104°F (40°C) |
| Sound Emission | 67 dB |
| Thermal Dissipation | 1300 BTU/h |
| Physical Characteristics | |
| Height | 5.16" (131 mm) |
| Width | 17.52" (445 mm) |
| Depth | 30" (762 mm) |
| Rack Height | 3U |
| Form Factor | Rack/Tower |
| Weight (Approximate) | 117.59 lb (53340 g) |
| Miscellaneous | |
| Package Contents | SmartOnline SU6KRT3UX 6kVA Rack/Tower UPS Pre-installed WEBCARDLXMINI Network Management Card 2 x Hardwire Strain Reliefs USB Cable RS-232 Cable Rack-mounting Hardware Owner's Manual |
| Software Included | PowerAlert |
| Energy Star | Yes |
| Country of Origin | Taiwan |
| TAA Compliant | Yes |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What is the power capacity of the SU6KRT3UX UPS?
The Tripp Lite by Eaton SmartOnline SU6KRT3UX provides 6 kVA (6000 VA) and 6 kW of power capacity. This unity power factor design means the volt-amp and watt ratings are equal, allowing the UPS to safely support more equipment within its capacity limits compared to units with lower power factors.
How long does this UPS provide backup power at full load?
At full 6 kW load, the SU6KRT3UX delivers approximately 3 minutes of backup runtime from its internal batteries. At half load (3 kW), runtime extends to approximately 8.5 minutes. These runtimes support graceful shutdown procedures or brief outage bridging for connected equipment.
What input voltage does this UPS require?
The SU6KRT3UX requires 230 V AC input voltage at 60 Hz frequency. The double conversion topology continuously conditions this input to provide clean output power regardless of utility power quality fluctuations or disturbances.
Can this UPS be mounted in a standard server rack?
Yes, the SU6KRT3UX is designed for both rack and tower deployment. In rack configuration, it occupies 3U of vertical space in standard 19-inch racks. The unit includes all necessary rack-mounting hardware and features a front panel LCD that rotates for optimal viewing in either rack or tower orientation.
What management capabilities does this UPS include?
The UPS includes a pre-installed WEBCARDLXMINI network management card that supports SNMP, Telnet, and SSH protocols for remote monitoring and control. The front panel features an LCD display with detailed status information and physical controls for local management. Serial, USB, and EPO ports provide additional connectivity options.
Are the batteries replaceable without shutting down the UPS?
Yes, the SU6KRT3UX features hot-swappable valve-regulated lead-acid batteries that can be replaced without powering down the UPS or interrupting power to connected equipment. The typical battery recharge time is 3 hours after a complete discharge, restoring full backup capacity quickly.
What power capacity is listed for this UPS?
The listed power specification is 6 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 230 V AC, which helps position the unit for the right load level and installation role.