Tripp Lite by Eaton SU750RTXLCD2UN SmartOnline 750VA/675W Double-Conversion Online UPS - 2U Rack-mountable - Pure Sine Wave - 6 Outlets
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This double-conversion online UPS accepts 120V AC input and delivers regulated output voltages selectable between 100V, 110V, 115V, and 127V AC at 60Hz. The pure sine wave output ensures clean power for active PFC power supplies and sensitive electronics, while a 570-joule surge energy rating provides protection against voltage spikes. The unit features EMI/RFI noise filtering and overload protection to safeguard connected equipment.
The 24V DC battery system supports hot-swappable and user-replaceable batteries, with a typical recharge time of three hours. Runtime is 4.3 minutes at full load and extends to 13.9 minutes at half load, providing sufficient time for graceful shutdowns or transition to backup power. Management interfaces include USB for local software control, a serial port for legacy integration, and an EPO port for emergency power-off scenarios.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
The SmartOnline SU750RTXLCD2UN combines high-efficiency double-conversion technology with a compact 2U rack design, making it an ideal power protection solution for space-constrained server racks and network closets. Its zero-transfer-time operation ensures uninterrupted power during outages, while the pure sine wave output guarantees compatibility with modern server power supplies and networking gear.
Network-Ready Management
The included WEBCARDLXE network management card provides 24/7 remote access via SNMP/HTTP, enabling real-time monitoring, configuration, and shutdown commands from any web browser or network management system.
- SNMP/HTTP Support
- Remote Configuration
- Alarm Notifications
Operational Efficiency
An optional Economy mode reduces energy consumption by bypassing the double-conversion process when input power is stable, lowering operating costs without compromising protection.
- Energy-Saving Mode
- Green Energy-Saving
- Reduced Power Draw
Comprehensive Protection
Beyond battery backup, this UPS includes dataline protection for RJ-11 and RJ-45 connections, safeguarding network and telephone lines from surges and spikes.
- Dataline Protection
- EMI/RFI Filtering
- Overload Protection
Deployment / Use Cases
This UPS is engineered for environments where power continuity is critical. Its 2U rack-mount form factor and 750VA capacity make it suitable for protecting single servers, network switches, routers, and storage arrays in small to medium-sized server rooms. The unit supports optional external battery packs for extended runtime, accommodating applications that require longer backup durations during prolonged outages.
Typical deployments include data center edge racks, network closets, telecommunications cabinets, and industrial control panels. The pure sine wave output and wide output voltage range ensure reliable operation with sensitive medical, laboratory, and financial equipment. The included tower support stands allow for flexible placement in non-rack environments, such as under-desk installations or small office settings.
Server Room & Data Center
Protect critical server and storage infrastructure with zero-transfer-time backup and network management for centralized monitoring.
- Rack-Mount Design
- SNMP Management
- Pure Sine Wave
Network & Telecom Closets
Ensure uninterrupted operation of switches, routers, and VoIP equipment with compact power protection and dataline surge suppression.
- 6 Outlets
- Dataline Protection
- 2U Footprint
Physical Profile
The UPS measures 3.50 inches in height, 17.52 inches in width, and 12.52 inches in depth, occupying a standard 2U rack space. Its rack-mountable design includes integrated mounting hardware for secure installation in 19-inch server racks. The unit weighs approximately 27.60 pounds, with a robust steel construction suitable for data center environments. Front-panel accessibility allows for easy monitoring and control without removing the unit from the rack.
- Width
- 17.52" (445 mm)
- Depth
- 12.52" (318 mm)
- Height
- 3.50" (89 mm)
- Weight
- 45 dB(A)
What's in the Box
The package includes all necessary components for immediate deployment in rack-mount or tower configurations.
Highlights
- 750VA/675W double-conversion online UPS with pure sine wave output
- 2U rack-mountable form factor for space-efficient server rack deployment
- Zero transfer time ensures uninterrupted power during outages
- Includes WEBCARDLXE network management card for SNMP/HTTP remote monitoring
- Six NEMA 5-15R outlets support multiple devices
- Hot-swappable, user-replaceable battery with 3-hour typical recharge time
- Optional Economy mode reduces energy consumption during stable input power
- Dataline protection for RJ-11 and RJ-45 connections
- 2-year limited warranty with 250,000 Ultimate Lifetime Insurance
- RoHS compliant and environmentally friendly
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | SU750RTXLCD2UN |
| Brand Name | Tripp Lite series |
| Product Line | SmartOnline |
| Product Model | SU750RTXLCD2UN |
| Product Name | SmartOnline SU750RTXLCD2UN 750VA Rack-mountable UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | NEMA 5-15P |
| Receptacle Type | NEMA 5-15R |
| Receptacle Detail | 6 x NEMA 5-15R |
| Dataline Protection | RJ-11,RJ-45 |
| Overload Protection | Yes |
| Transfer Time | 0 ns |
| EMI/RFI Noise Filter | Yes |
| Phase | Single Phase |
| Energy Saving | Green Energy-Saving |
| Application/Usage | Mission Critical Equipment,Data Center,Computer Room,Network Closet,Server |
| Power Description | |
| Load Capacity (VA) | 750 VA |
| Load Capacity (Watt) | 675 W |
| Input Voltage | 120 V AC |
| Output Voltage | 100 V AC,110 V AC,115 V AC,127 V AC |
| Input Frequency | 60 Hz |
| Output Frequency | 60 Hz |
| Waveform Type | Pure Sine Wave |
| Surge Energy Rating | 570 J |
| Management | |
| Network Management | SNMP/HTTP Remote Monitoring |
| Alarm | UPS StartUp,Power Failure,Low Battery,Overload,UPS Fault,Remote Shutdown |
| Controls/Indicators | |
| Status Indicators | 7 Front Panel LEDs Indicator: AC To DC Conversion Battery Mode Operation Inverter Mode ECO Mode Operation Bypass Mode Operation AC Output Status Front Panel LCD Display: UPS And Site Power Status And Operating Data Configuration Of Voltage Frequency Operating Mode Alarm Function And A Variety Of Additional Options |
| Interfaces/Ports | |
| Serial Port | Yes |
| EPO Port | Yes |
| USB (HID Compliant) Port | Yes |
| Battery Information | |
| DC System Voltage | 24 V DC |
| Backup/Run Time (Full Load) | 4.30 Minute |
| Backup/Run Time (Half Load) | 13.90 Minute |
| Hot Swappable | Yes |
| Typical Battery Recharge Time | 3 Hour |
| Replaceable Battery | Yes |
| Environmental Conditions | |
| Maximum Operating Elevation | 10000 ft (3048000 mm) |
| Storage Temperature | 5°F (-15°C) - 122°F (50°C) |
| Maximum Operating Temperature | 104°F (40°C) |
| Sound Emission (A-Weighted) | 45 dB(A) |
| Physical Characteristics | |
| Height | 3.50" (89 mm) |
| Width | 17.52" (445 mm) |
| Depth | 12.52" (318 mm) |
| Rack Height | 2U |
| Form Factor | Rack-mountable |
| Weight (Approximate) | 27.60 lb (12520 g) |
| Miscellaneous | |
| Package Contents | 750VA 675W 120V Double-Conversion UPS WEBCARDLXE network management card USB cable DB9 cable Rack-mounting hardware Tower support stands Safety instructions Quick start guide |
| Country of Origin | Philippines |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What is the runtime of this UPS at full and half load?
The UPS provides 4.3 minutes of backup runtime at full load (675W) and extends to 13.9 minutes at half load (337.5W). These runtimes allow sufficient time for connected equipment to perform graceful shutdowns or transition to alternative power sources during an outage.
How many outlets does this UPS have and what type are they?
This UPS includes six NEMA 5-15R outlets, which are standard 15-amp receptacles commonly used in North America. All outlets provide battery backup and surge protection, supporting multiple devices such as servers, switches, and storage units within a single rack installation.
What management options are available for remote monitoring?
The included WEBCARDLXE network management card enables remote monitoring and control via SNMP and HTTP protocols. This allows IT administrators to view real-time status, configure settings, and initiate shutdowns from any web browser or network management system, providing 24/7 oversight without physical access.
Can the batteries be replaced without shutting down the UPS?
Yes, the UPS supports hot-swappable battery replacement. This feature allows you to replace the internal batteries while the unit remains operational, ensuring continuous power protection to connected equipment during maintenance without requiring a system shutdown.
What is the input voltage and output waveform of this UPS?
The UPS accepts 120V AC input and delivers a pure sine wave output at selectable voltages of 100V, 110V, 115V, or 127V AC. The pure sine wave ensures compatibility with sensitive active PFC power supplies found in servers, networking gear, and medical equipment, preventing potential damage or instability.
Is this UPS suitable for rack-mount installation?
Yes, this UPS is designed for 2U rack-mount installation in standard 19-inch server racks. It includes all necessary mounting hardware and has dimensions of 3.50 inches high, 17.52 inches wide, and 12.52 inches deep, making it ideal for data center, server room, and network closet deployments where space optimization is critical.
What power capacity is listed for this UPS?
The listed power specification is 750 VA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 120 V AC, which helps position the unit for the right load level and installation role.