Tripp Lite by Eaton SUINT1000LCD2U SmartOnline 1kVA 900W On-Line Double-Conversion UPS - 2U Rack/Tower - 7. 3 Min Full Load Runtime
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This SmartOnline UPS employs double-conversion technology to isolate connected equipment from raw utility power, providing consistent output voltage and frequency. The input power factor of 0.99 and output power factor of 0.9 optimize energy efficiency, supported by ENERGY STAR 2.0 certification.
Electrical specifications include a surge energy rating of 296 joules and input/output voltages spanning 200-240 V AC. The unit features eight IEC 60320 C13 receptacles with two load management outlets, a 6-foot cord, and USB connectivity for local monitoring. Battery management includes hot-swappable, valve-regulated lead-acid batteries with a 48V size and replaceable design.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
The SUINT1000LCD2U combines robust power protection with user-friendly management. The LCD display offers menu-driven access to vital analytics, while network management options include contact closure, RS-232, and SNMP/Web interfaces for remote monitoring and control.
These strengths make the product easier to deploy and manage in real environments, especially where reliability, usability, and day-to-day operational continuity matter. Notable benefits include Uninterrupted Operation, Energy Efficiency.
Uninterrupted Operation
Zero transfer time ensures seamless transition to battery power during outages, preventing data loss and equipment damage.
- Pure sine wave output
- 0 ns transfer time
- Double-conversion topology
Energy Efficiency
High efficiency economy mode reduces electricity consumption and operational costs while meeting ENERGY STAR 2.0 standards.
- Input power factor 0.99
- Output power factor 0.9
- Individually controllable load banks
Deployment / Use Cases
Deploy this UPS in environments requiring reliable power backup for file servers, network switches, medical devices, or security systems. The rack/tower design allows placement in standard 19-inch racks or as a standalone tower using included support stands.
Typical applications include protecting small office networks, point-of-sale systems, laboratory equipment, and telecommunications infrastructure. The 17.9-minute half-load runtime extends operational continuity during extended outages.
Server Room Protection
Ideal for rack-mounted servers and networking equipment in small data centers, providing 7.3 minutes of full-load runtime for safe shutdowns.
- 2U rack-mountable
- 8 IEC C13 outlets
- SNMP/Web management
Critical Infrastructure
Supports mission-critical applications in healthcare, education, and government facilities where power quality and uptime are essential.
- Pure sine wave output
- EMI/RFI filtering
- Wide input voltage range
Physical Profile
The SUINT1000LCD2U features a compact 2U form factor measuring 3.41 inches in height, 17.33 inches in width, and 17.72 inches in depth. With an approximate weight of 36.38 pounds, it integrates easily into standard server racks while maintaining a low acoustic profile of 40 dB(A).
Construction includes rack-mounting hardware and tower support stands for flexible installation. The unit operates within a temperature range of 32°F to 104°F and stores safely up to 10,000 feet elevation, with thermal dissipation rated at 438 BTU/h.
- Width
- 17.33" (440.18 mm)
- Depth
- 17.72" (450.09 mm)
- Height
- 3.41" (86.61 mm)
- Weight
- 40 dB(A)
- Length
- 6 ft (1.83 m)
What's in the Box
The package includes all necessary components for immediate deployment: the 1000VA 900W 208/230V double-conversion UPS, USB cable, DB9 cable, two IEC 10A 6-foot output cables, rack-mounting hardware, tower support stands, safety instructions, and a quick start guide.
Highlights
- 1 kVA / 900 W on-line double-conversion UPS with pure sine wave output
- 2U rack/tower form factor with included mounting hardware and support stands
- 7.3-minute full-load runtime and 17.9-minute half-load runtime
- Zero transfer time between on-line and battery modes
- Eight IEC 60320 C13 receptacles with two load management outlets
- Menu-driven LCD display for real-time status and analytics
- Network management via contact closure, RS-232, and SNMP/Web
- Hot-swappable, valve-regulated lead-acid batteries with 3-hour recharge
- ENERGY STAR 2.0 certified with high efficiency economy mode
- 2-year limited warranty with optional 5-year extended coverage plans
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | SUINT1000LCD2U |
| Brand Name | Tripp Lite series |
| Product Line | SmartOnline |
| Product Model | SUINT1000LCD2U |
| Product Name | SUINT1000LCD2U SmartOnline 1kVA 900W On-Line Double-Conversion UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | IEC 60320 C14 |
| Receptacle Type | IEC 60320 C13 |
| Receptacle Detail | 8 x IEC 60320 C13 |
| Number of Load Management Outlets | 2 |
| Cord Length | 6 ft (1.83 m) |
| Transfer Time | 0 ns |
| EMI/RFI Noise Filter | Yes |
| Phase | Single Phase |
| Energy Saving | High efficiency economy mode operation; Individually controllable load banks |
| Application/Usage | Mission Critical Equipment,Education,Healthcare,Military,Government |
| Power Description | |
| Load Capacity (VA) | 1 kVA |
| Load Capacity (Watt) | 900 W |
| Input Voltage | 200 V AC,208 V AC,220 V AC,230 V AC,240 V AC |
| Input Current | 6 A |
| Output Voltage | 200 V AC,208 V AC,220 V AC,230 V AC,240 V AC |
| Input Frequency | 40 Hz,70 Hz |
| Output Frequency | 50 Hz,60 Hz |
| Waveform Type | Pure Sine Wave |
| Surge Energy Rating | 296 J |
| Input Power Factor | 0.99 |
| Output Power Factor | 0.9 |
| Display & Graphics | |
| Display | LCD |
| Management | |
| Network Management | Contact Closure,RS-232,SNMP/Web |
| Alarm | UPS StartUp,Power Failure,Low Battery,Overload,UPS Fault,Remote Shutdown |
| Controls/Indicators | |
| Status Indicators | 4 x Status-indicating LEDs |
| Interfaces/Ports | |
| USB | Yes |
| Battery Information | |
| Battery Characteristics | Valve-regulated |
| Battery Chemistry | Lead Acid |
| Battery Size | 48V |
| Backup/Run Time (Full Load) | 7.30 Minute |
| Backup/Run Time (Half Load) | 17.90 Minute |
| Hot Swappable | Yes |
| Typical Battery Recharge Time | 3 Hour |
| Replaceable Battery | Yes |
| Environmental Conditions | |
| Maximum Storage Elevation | 10000 ft (3048000 mm) |
| Storage Temperature | -13°F (-25°C) - 131°F (55°C) |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Operating Temperature | 104°F (40°C) |
| Sound Emission (A-Weighted) | 40 dB(A) |
| Thermal Dissipation | 438 BTU/h |
| Physical Characteristics | |
| Height | 3.41" (86.61 mm) |
| Width | 17.33" (440.18 mm) |
| Depth | 17.72" (450.09 mm) |
| Rack Height | 2U |
| Form Factor | Rack/Tower |
| Weight (Approximate) | 36.38 lb (16501.69 g) |
| Miscellaneous | |
| Package Contents | 1000VA 900W 208/230V Double-Conversion UPS USB cable DB9 cable (2) IEC 10A 6ft. output cables Rack-mounting hardware Tower support stands Safety instructions Quick start guide |
| Energy Star | Yes |
| Country of Origin | Philippines |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 2 Year |
| Additional Warranty Information | 5-year depot exchange plan: TL9SW5Y-1500UC Expedited parts coverage for 5 years Parts, electronics and UPS batteries coverage Next business day shipping Technical support 5-year onsite plan: TLWFLN75XX-2509UC Onsite parts and labor coverage for 5 years Parts, electronics and UPS batteries coverage 24x7 onsite labor coverage, next-day response Next-day shipping Technical support |
User Manual
FAQ
What is the power capacity of the SUINT1000LCD2U UPS?
The Tripp Lite by Eaton SUINT1000LCD2U provides 1 kVA (1000 VA) and 900 watts of power capacity. This rating supports connected equipment drawing up to 900 watts while delivering clean, uninterrupted power through its double-conversion topology.
How long does the battery last during a power outage?
At full load (900 watts), the UPS provides 7.3 minutes of runtime. At half load (450 watts), runtime extends to 17.9 minutes. These times allow for safe shutdown of servers and network equipment or continued operation during brief outages.
What input voltages does this UPS support?
The SUINT1000LCD2U accepts input voltages of 200 V AC, 208 V AC, 220 V AC, 230 V AC, and 240 V AC. It delivers the same output voltage range, making it compatible with standard North American and international power systems without requiring voltage adjustment.
Can this UPS be mounted in a server rack?
Yes, this UPS features a 2U rack-mountable design with included rack-mounting hardware. It also includes tower support stands for standalone deployment. The compact dimensions (3.41"H x 17.33"W x 17.72"D) fit standard 19-inch server racks.
What type of power output does this UPS provide?
The SUINT1000LCD2U delivers pure sine wave output, which is essential for sensitive electronic equipment like servers, medical devices, and networking gear. This clean power waveform prevents compatibility issues and ensures optimal performance of connected devices.
How is the UPS managed and monitored?
Management options include a front-panel LCD display for local monitoring, USB connectivity for computer-based management, and network interfaces including contact closure, RS-232, and SNMP/Web. These tools provide status alerts, runtime estimates, and remote shutdown capabilities.
What power capacity is listed for this UPS?
The listed power specification is 1 kVA, which helps position the unit for the right load level and installation role.
How many outlets are available?
The product includes 2, which helps buyers understand how many connected devices it can support in its intended deployment.